Résumé du contenu de la page N° 1
Temperature
Cooler Warmer
Cool Power
Fan Fan Money
®
Only Speed Saver
Timer Operation
On/Off Start Stop Set Hr.
Room Air Conditioners
Standard Chassis Models
115-Volt: SS08, SS10, SS12, SS14
230-Volt: SS12, SS16, SM18, SM21, SM24
115-Volt: KS12, KS15
230-Volt: KM18, KM24
230-Volt: SL28, SL36
HEAVY DUTY
115-Volt: YS09
230-Volt: YS13, YM18, YL24, ES12, ES16, EM18, EM24, EL36
Register your air conditioner
Model information can be found on the name
plate behind the front cover.
Please complete and
Résumé du contenu de la page N° 2
920-198-00 Congratulations! You have purchased the very latest in room air conditioner technology. Your new Friedrich high effi ciency room air conditioner will give you many years of de- pendable service. Many extra features have been built into your Friedrich air conditioner to assure quiet operation, the best circulation of cool, dry air, functional controls, and the most economical operation. Table of contents Air Conditioner Operation Before Operating Your Unit .............................
Résumé du contenu de la page N° 3
920-198-00 WARNING: Before operating your unit Make sure the wiring is adequate for your unit. CIRCUIT RATING REQUIRED WALL If you have fuses, they should be of the time delay type. Before you install OR TIME DELAY RECEPTACLE or relo cate this unit, be sure that the amperage rating of the circuit breaker FUSE MODEL or time delay fuse does not exceed the amp rating listed in Figure 1. NEMA AMP VOLT NO. DO NOT use an extension cord. The cord provided will carry the proper amount of electric
Résumé du contenu de la page N° 4
920-198-00 How to operate your Friedrich room air con diti on er (QuietMaster Programmable) To start unit 1 If your air conditioner is installed and plugged into a proper re- Figure 3 cep tac le, it is ready to go. Touch Power button once. The unit will automatically be in Cool mode with the temperature set at 75°F (24°C) and the fan speed at F1, the sleep setting. There is a 3- PM minute delay before the compressor will turn on. (See "Automatic Component Protection" on this page). DISPLAY
Résumé du contenu de la page N° 5
920-198-00 * How to use the remote control (QuietMaster Programmable) To start unit To set the timer 1 POWER - Press the Power button once. The unit will automatically NOTE: Set the hour clock before attempting to set timer functions. You turn on in the mode and fan speed it was last left on. can set the timer On/Off a minimum of one hour apart, and a maximum of 23 hours apart. To set mode of operation 9 TIMER START - Press Start to view the current start time for cool- ing. Continue press
Résumé du contenu de la page N° 6
920-198-00 How to operate your Friedrich room air con diti on er (QuietMaster 'K' & Heavy Duty models / Twintemp models) To start unit If your air conditioner is installed and plugged into a properly grounded re cep ta cle, it is ready to oper ate. Mode control (QuietMaster ‘K’ and Heavy Duty) The upper dial (Figure 5) allows you to select cooling at four different Off SPEED speeds, as well as Fan Only (Models SL28 and SL36 only have three cooling speeds.). Fan Sleep Only Setting Off - to
Résumé du contenu de la page N° 7
920-198-00 Care and Maintenance / Fresh air and exhaust control To remove, wash and replace filter and return air grille Open the return air (RA) grille by grasping it at the top outside edges and pulling towards you (See Figure 7). The RA grille will stay open until it is detached or closed (it is easier to completely detach the grille before closing it). To remove the RA grille, grasp it at the bottom and pull towards you. The fi lter is held in place by two spring clips (See Figure 7). Push
Résumé du contenu de la page N° 8
920-198-00 Installation In structi ons ® NOTE: This manual includes installation instructions for window mount and thru-the-wall mount methods. TwinTemp heat/cool units are designed for permanent thru-the-wall installation. Mounting the unit in a window will require a window mounting accessory kit, available through your Friedrich dealer. Read This First! Electrical Requirements IMPORTANT: Before you begin the actual installation of your air conditioner, Refer to the electrical data plate loca
Résumé du contenu de la page N° 9
920-198-00 Window Mount Thru-the-wall Installation Hardware Installation Hardware ITEM ITEM DE SCRIP TION QTY. QTY. DE SCRIP TION NO. NO. MOUNT ING PARTS SHELL MOUNT ING PARTS 4 SCREW, SHEET METAL #12A x 2" 7 1 SUPPORT BRACKET 2 14 CHASSIS SEAL GASKET (LIGHT FOAM) 1 2 SCREW, 10-24 x 1" HEX HEAD 4 3 10-24 FLAT WELD NUT 4 4 SCREW, SHEET METAL #12A x 2" 7 WINGBOARD ANGLE MOUNTING 5 WINGBOARD ANGLE, TOP 1 6 WINGBOARD ANGLE, SIDE 2 3 7 SCREW, SHEET METAL #8A x ⁄8" 2 WINGBOARD MOUNTI
Résumé du contenu de la page N° 10
920-198-00 Standard Sash Window Installations STEP 1 Remove decorative plastic return air grille to a safe area away STEP 5 Anchor the side angles (Item #6) by engaging the tabs at each from unit. The return air grille can be removed by pulling at the end of the sill plate (see Figure B) with the bottom loops of the sides on either the top or bottom. side angle. Engage the tabs at each end of the top angle (Item #5) with the top loops of the side angle (see Figure B). Install STEP 2 Also re
Résumé du contenu de la page N° 11
920-198-00 STEP 8 OUTSIDE SUPPORT MOUNTING – Assemble the support Figure C brackets (Item #1) to the bottom rails of the cabi net with four (4) 10-24 1" long screws (Item #2) and four (4) 10-24 fl at nuts TOP (Item #3). Adjust the support brackets to bring the bottom pads SUPPORT CENTER ANGLE CABINET IN in contact with the wall surface. (A 1" x 4" or 2" x 4" SPACER WINDOW SIDE PULL SHOULD BE USED BETWEEN THE WALL AND THE TO SIDE. WINDOW SUPPORT BRACKETS WHEN IN STALLED ON ALU MI NUM
Résumé du contenu de la page N° 12
920-198-00 Figure 1A TYPICAL MOUNTING SCHEME Figure 2A MODIFIED MOUNTING SCHEME 10 - 24 SCREW ⅜" SLOPE DOWN 10 - 24 FLAT NUT ⅜" SLOPE DOWN SUPPLY AIR CONDENSER AIR OUTLET RETURN AIR CUT DIMENSION "A" HERE CONDENSER AIR INLETS STONE LEDGE #12A x 2" SHEET METAL OUTSIDE WALL SCREW 1" x 4" OR 2" x 4" SPACER CUT TO FIT DIMENSION "A" DISCARD BE TWEEN WALL AND AND BEND DOWN TO FORM A SHADED AREA BRACKET SHOULD BE VER TI CAL LEG. USED ON ALUMINUM, ASBESTOS OR VINYL SIDING. Figure 3A
Résumé du contenu de la page N° 13
920-198-00 STEP 11 INSTALL THE SIDE WINGBOARD PANELS – Be sure the STEP 13 When possible, caulk the outside of the installation with cabinet has been secured to the wind ow sill and that the out- industrial type caulking to prevent weather l eaks. side support brackets have been installed as shown in Figure STEP 14 INSTALL CHASSIS – After installing the shell, slide the chassis D. Raise the window sash and install the right and left side into the shell stopping approximately 3" from full
Résumé du contenu de la page N° 14
920-198-00 STEP 16 OPTIONAL: The factory assembles the supply cord so that STEP 17 Be sure the fi lter is in place before installing the return air grille it exits the left side of the unit. At the consumer’s discretion, (See Figure J), and that the electrical cord is properly routed the supply cord can be made to exit the right side of the unit. so not to interfere with the installation. (See Step 16.) To do this, remove the black rubber coated cord clamp from STEP 18 Pick up the grille
Résumé du contenu de la page N° 15
920-198-00 Through-the-wall Installations The following instructions apply to wood, masonry, brick, concrete or cinder block wall con struc tion STEP 1 Follow steps 1, 2, 3 and 4 of the "STANDARD SASH WINDOW STEP 3 WALL PREPARATION – The maximum wall thickness permis- INSTALLATION" instructions beginning on page 10. sible without special construction is de term ined by the model size to be installed. THE OUTSIDE CABINET CONDENSER-AIR- STEP 2 CABINET PREPARATION – Remove the sill plate from the
Résumé du contenu de la page N° 16
920-198-00 STEP 4 CHECKING WIRING AND PLUMBING: Check all wiring and Figure D plumbing inside and outside of the wall to be sure none will be BRICK VENEER CONSTRUCTION broken where the hole is to be cut. STEP 5 HOLE CONSTRUCTION: Depending upon size of unit to be SHIM VOID SPACES AT TOP AND installed, lay out the hole dimensions per the chart below. Cut SIDES WITH WOOD AS REQUIRED and frame in hole to fi nished dimensions. Use 2" x 4" material for framing and follow the suggested typical i
Résumé du contenu de la page N° 17
920-198-00 Figure F TYPICAL INSTALLATION CAULK ALL SIDES WEATHER TIGHT TRIM MOULDING ⅜" SLOPE DOWN SCREW #12A x 2" NOTE: SUPPORT BRACKETS MAY BE OMIT TED LONG (USE 3) FROM THROUGH-THE-WALL IN STAL LA TIONS IF THE CABINET IS SECURED AS FOL LOWS. DRILL 2 HOLES IN EACH SIDE AND IN STALL 4 FAS TEN ERS (2 EACH SIDE). USE #12 x 2" SCREWS, TOGGLE BOLTS OR EX PAN SION ANCHOR BOLTS AS SHOWN IN STEP 7. CABINET SILL PLATE GUIDE CHANNEL SUPPORT BRACK ETS (AVAILABLE AS OPTI ONAL AC CES SORY ) SCREW
Résumé du contenu de la page N° 18
920-198-00 Troubleshooting tips Power failure Noises If you have a power failure, the unit's auto-restart feature will resume All air conditioners make some noise. Friedrich QuietMaster® units are operation in the selected mode prior to the power failure. designed to operate as quietly as possible. An air conditioner mounted in a wall is quieter than one mounted in a window. It is important to ensure Won't cool? that the chassis seal gasket is properly installed (refer to installation If yo
Résumé du contenu de la page N° 19
920-198-00 Friedrich Air Conditioning Company P.O. Box 1540 San Antonio, TX 78295 210.357.4400 www.friedrich.com ROOM AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible for service. Any additional labor cost for removing inaccessible units and/or
Résumé du contenu de la page N° 20
920-198-00 ¡Enhorabuena! Acaba de comprar la tecnología más avanzada en unidades de aire acondicionado de tipo ventana. Su unidad de aire acondicionado de tipo ventana Friedrich le dará muchos años de servicio de confi anza. Este modelo incorpora muchas características para garantizar el funcionamiento silencioso, la mejor circulación posible del aire frío, aire seco, controles funcionales y un funcionamiento económico. Contenido Funcionamiento del aire acondicionado Antes de utilizar la unidad