Résumé du contenu de la page N° 1
Service Manual
Model:
P09A
P09B
Portable Air Conditioner
P012A
P012B
PORT-ServMan (04-09)
Résumé du contenu de la page N° 2
TECHNICAL SUPPORT CONTACT INFORMATION FRIEDRICH AIR CONDITIONING CO. Post Office Box 1540 · San Antonio, Texas 78295-1540 4200 N. Pan Am Expressway · San Antonio, Texas 78218-5212 (210) 357-4400 · FAX (210) 357-4490 www.friedrich.com Printed in the U.S.A.
Résumé du contenu de la page N° 3
Table Of Contents Important Safety Information ....................................................................................................................2-4 Introduction ..................................................................................................................................................4 Unit Introduction ..........................................................................................................................................5 Unit Model
Résumé du contenu de la page N° 4
IMPORTANT SAFETY INFORMATION The information contained in this manual is intended for use by a qualified service technician who is familiar with the safety procedures required for installation and repair, and who is equipped with the proper tools and test instruments required to service this product. Installation or repairs made by unqualified persons can result in subjecting the unqualified person making such repairs as well as the persons being served by the equipm
Résumé du contenu de la page N° 5
• Do not spray or pour water on the return air grille, discharge air grille, evaporator coil, control panel, and sleeve on the room side of the air conditioning unit while cleaning. • Electrical component malfunction caused by water could result in electric shock or other electrically unsafe conditions when the power is restored and the unit is turned on, even after the exterior is dry. • Never operate the A/C unit with wet hands. • Use air conditioner on a single dedicated circuit withi
Résumé du contenu de la page N° 6
PROPERTY DAMAGE HAZARDS FIRE DAMAGE HAZARDS: • Read the Installation/Operation Manual for this air conditioning unit prior to operating. • Use air conditioner on a single dedicated circuit within the specified amperage rating. • Connect to a properly grounded outlet only. • Do not remove ground prong of plug. • Do not cut or modify the power supply cord. • Do not use extension cords with the unit. • Failure to follow these instructions can result in fire and minor to serious property dam
Résumé du contenu de la page N° 7
UNIT INTRODUCTION 1. Control panel 2. Air outlet 3. Signal receptor 4. Handle 5. Caster 6. Air outlet hose 7. Air filter 8. Air intake hose 9. 1/2" water outlet drain 10. Power supply cord 5
Résumé du contenu de la page N° 8
UNIT MODEL AND SERIAL NUMBER UNIT IDENTIFICATION MODEL NUMBER CODE P 09 A Portable 2nd and 3rd DIGIT - Approximate BTU/HR (Cooling) Heating BTU/Hr capacity listed in the Specification/Performance Data Section Design Series RAC SERIAL NUMBER IDENTIFICATION GUIDE Serial Number L H G K 00001 Decade Manufactured L=0 C=3 F=6 J=9 Production Run Number A=1 D=4 G=7 B=2 E=5 H=8 Year Manufactured Product Line A=1 D=4 G=7 K=0 R = RAC B=2 E=5 H=8 C=3 F=6 J=9 Month Manufactured A=Jan D=Apr G=
Résumé du contenu de la page N° 9
TECHNICAL SPECIFICATIONS P09A AND P12A Indoor Air Refrigerant Locked Net Cooling Capacity Dimensions De h u m i d ific a t i o n Circulation Charge) Rotor Weight Circuit Plug Face Model BTU/h Voltage / Hz Amps Watts (W” x H” x D”) (Pints/Hour) (CFM) (R-22) Amps (lbs.) Rating (NEMA#) P09A 8900 115/60 8 923 19.5” x 33.6” x 15.5” 4.2 212 18 40.5 80 125V/15A 5-15P P12A 11500 115/60 10.5 1280 19.5” x 33.6” x 15.5” 4.2 235 24.7 40.5 86 125V/15A 5-15P Indoor Air Refrigerant Locked Net Cooling Capacity
Résumé du contenu de la page N° 10
PRECAUTIONS FOR USE • Make sure the unit is installed in an accessible location. • Do not locate the unit in direct sunlight so as to avoid discoloration of the plastic. • Keep the unit 1 meter away from television sets or radios to avoid the risk of electromagnetic interference. • Ensure that the discharge air outlet is free from obstructions and not impeded by walls or other structures. • Operate the unity ONLY in the upright position. • When unplugging the unit, hold the power plug s
Résumé du contenu de la page N° 11
CONTROL PANEL OPERATION Dehumidifying and cooling operation Mode control The operating range for cooling operation is 60°F - 90°F, The mode control has three settings– Cool, Dehumidify and the operating range for dehumidifying is 68°F - 88°F. and Fan. The settings are adjusted with the Mode Control button. A light will indicate which setting is currently being Power source used. • The AC socket must be firm and reliable. Cooling operation • Don’t connect the portable air conditioner to a m
Résumé du contenu de la page N° 12
REMOTE CONTROL Air Conditioner Remote Control The functions work the same as your air conditioner’s touch controls. All key function can be accessed from the remote control. Power Control LCD Display On/Off Time/Temperature Set Control Fan Speed Control • Used for adjusting the timer and temperature : HIGH : MED :LOW • The default display on control panel is room temperature. • When the " " or the " " button is pressed in cool mode, the set temperature is displayed On / Off Timer
Résumé du contenu de la page N° 13
Window adapter kit Window adapter kit WINDOW ADAPTER KIT INSTALLATION Window adapter kit Window adapter kit Window adapter kit An installation parts kit is packed with your unit in a separate An installation parts kit is packed with your unit in a separate Window panel extensions An installation parts kit is packed with your unit in a separate carton. Before you discard the packaging that your unit came carton. Before you discard the packaging that your unit came Window panel extensions carton
Résumé du contenu de la page N° 14
Installing the window adapter kit Note: The window adapter kit must be installed and connected for the air conditioner to work properly in Cool mode. The window adapter kit is not required when using the unit in Dehumidify or Fan modes. Your window adapter kit has been designed to fit most Window installation standard vertical and horizontal window applications. However, it may be necessary for you to modify some aspects of the installation procedures for certain types of windows. Install
Résumé du contenu de la page N° 15
Maintenance Proper use and care of Cleaning and Maintenance 10 Removing the filter your air conditioner will • The unit has an air filter that must be cleaned with help ensure longer life of water every two weeks and put back in the unit after it the unit. It is is completely dry. recommended to have a • The air discharge grille can be cleaned with a rag or professional annually sponge, warm water and mild detergent. inspect and clean the coils • Never use hot water, bleach, gasoline, acids, clean
Résumé du contenu de la page N° 16
MAINTENANCE / SERVICE WARNING RISK OF ELECTRIC SHOCK Unplug and/or disconnect all electrical power to the unit before performing inspections, maintenances or service. Failure to do so could result in electric shock, serious injury or death. Cleaning the air filter If the air filter is blocked with a lot of dust, the air flow volume will be reduced. Clean the filter once every two weeks. Open and clean the air filter: 1. Pull the filter out as shown in the drawing. 2. Take out the air f
Résumé du contenu de la page N° 17
TROUBLESHOOTING 15
Résumé du contenu de la page N° 18
TROUBLESHOOTING Unblock (below72 F) The compressor bolts are Tighten bolts loose or copper tubes are Adjust copper tubes contacting other metal parts 16
Résumé du contenu de la page N° 19
REFRIGERATOR SYSTEM DIAGRAM SCHEMATIC WIRING DIAGRAM 17
Résumé du contenu de la page N° 20
Friedrich Air Conditioning Company P.O. Box 1540 San Antonio, TX 78295 210.357.4400 www.friedrich.com PORTABLE AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no charge, provided the product is transported to a Friedrich Authorized Service Center for repair. ALL transportation charges are the sole respons