Résumé du contenu de la page N° 1
A
D
A
C
O
M
P
L
I
Installation
Instructions
MG-2/TT
Express® Lavatory
System - MG-Series
®
with TouchTime Control
Table of Contents
Pre-Installation Information . . . . . . . . . . . . . . . . . .2
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
Installation Instructions . . . . . . . . . . . . . . . . . . 5-12
Cleaning and Maintenance . . . . . . . . . . . . . . . . . .13
Assembly of Components . . . . . . . . . . . . . . . .14-16
Solenoid Valve Troubleshooting . . . . .
Résumé du contenu de la page N° 2
Express® Lavatory System - MG-Series with TouchTime® Control MG-2/TT Installation Instructions Pre-Installation Information Barrier-free and ADA compliant - standard height mounting The MG-2/TT Express® Lavatory System must have a rim height no higher than 34" above finished floor to be compliant with Americans with Disabilities Act (ADA). When mounted at 34" rim height, the MG-2/TT Express® Lavatory System meets ADA, ANSI and UFAS requirements for barrier-free clearances, reaches and controls.
Résumé du contenu de la page N° 3
A D A C O M P L I Express® Lavatory System - MG-Series with TouchTime® Control Installation Instructions MG-2/TT MG-2/TT Express® Lavatory System Dimensions 54" (mm) (1372) 42" (1067) 15" 15" (381) (381) (mm) 27" (686) 47" (1194) 22" (mm) (559) 9-1/2" (241) 21-1/2" (546) *39" (991) *33-1/2" (851) *29-1/2" *17-1/2" (749) (445) *Subtract 4" from vertical dimensions for compliance with ADA guidelines for children's use. Bradley Corporation • 215-1480 Rev. E; EN 06-915 2/8/07 3 A N T
Résumé du contenu de la page N° 4
Express® Lavatory System - MG-Series with TouchTime® Control MG-2/TT Installation Instructions Dimensions continued . . . (mm) 35-1/2" (902) TAS Juvenile Height 30" (762) Grades Pre-K thru 5 or 6 FLOOR 14" 26" (356) (660) (mm) 37-1/2" (952) TAS Juvenile Height 32" Grades 6 thru 8 or 9 (813) 16" FLOOR 28" (406) (711) 4 2/8/07 Bradley Corporation • 215-1480 Rev. E; EN 06-915
Résumé du contenu de la page N° 5
Express® Lavatory System - MG-Series with TouchTime® Control Installation Instructions MG-2/TT Installation Instructions Step 1: Rough in supplies and optional hot water heater NOTE: See Figure 1 (below), 1a, 1b (for TAS on page 6) and Figure 2 (on page 7) when roughing in the MG-2/TT Express®. IMPORTANT: Flush the supply lines before making connections. Debris in supply lines will cause the valves to malfunction. IMPORTANT: Dimensions shown in Figure 1 are for Standard Height Mounted MG-2/TT
Résumé du contenu de la page N° 6
Express® Lavatory System - MG-Series with TouchTime® Control MG-2/TT Installation Instructions TAS - Texas Accessibility CENTERLINE OF FIXTURE Standards: 25-1/2" (648) Juvenile Height (grades 25-1/2" (648) Pre-K thru 5 or 6) APPROX. DIMENSION APPROX. DIMENSION 1-1/2" NPT DRAIN 14" 14" RECOMMENDED STUB OUT 2" (356) (356) 240V/208V OR 277V FOR OPTIONAL 4" 4" (102) RECOMMENDED 240V/208V ELECTRICAL BOX (102) OR 277V FOR OPTIONAL LOCATION 16-1/2" ELECTRICAL BOX (4"l x 3"w x 4"h) (419) 4" LOCATION (1
Résumé du contenu de la page N° 7
Express® Lavatory System - MG-Series with TouchTime® Control Installation Instructions MG-2/TT Installation Instructions continued . . . Step 2: Rough in wall anchors and electrical outlet IMPORTANT: Turn OFF electrical power to the outlet when installing the Express® Lavatory System. 1. Install a 110 volt GFI protected electrical outlet per local code at the location shown in Figure 2. 2. Install six 3/8" wall anchors with a minimum pull-out rating of 1,000 lbs. (supplied by installer) at the
Résumé du contenu de la page N° 8
Express® Lavatory System - MG-Series with TouchTime® Control MG-2/TT Installation Instructions Installation Instructions continued . . . Step 3: Mount frame to wall 1. Loosen, but do not remove the three bottom access panel screws. 2. Remove the two top access panel screws and washers securing the access panel to the frame and remove the access panel (see Figure 3). 3. Position the frame with Terreon® End Caps attached, against the wall, ensuring that it is level. IMPORTANT: Anchoring the f
Résumé du contenu de la page N° 9
Express® Lavatory System - MG-Series with TouchTime® Control Installation Instructions MG-2/TT Installation Instructions continued . . . Step 4: Install bowl assembly IMPORTANT: See Figure 4 below when installing the bowl assembly. If the fixture has soap option, refer to the soap installation manual 215-1585 before installing the bowl assembly. 1. With someone to assist you, place the bowl assembly squarely onto the frame being careful not to pinch tubing between bowl and frame. 2. Attach the
Résumé du contenu de la page N° 10
Express® Lavatory System - MG-Series with TouchTime® Control MG-2/TT Installation Instructions Installation Instructions continued . . . Step 5: Connecting supply 1. Loosen but do not remove the two mounting screws holding the valve bracket to the frame. Slide the valve bracket up until the larger cutout in the frame’s slot aligns with the screw head (see Figure 5b). Then lift up to remove the valve bracket from the frame. 2 FOR HOT AND COLD SUPPLY: Attach the stop/check to the hot and cold wat
Résumé du contenu de la page N° 11
Express® Lavatory System - MG-Series with TouchTime® Control Installation Instructions MG-2/TT Installation Instructions continued . . . WATER Step 6: Connecting optional hot water heater HEATER NOTE: 240/208 or 277 voltage is required for hot water heater. Refer to the installation manual provided with the hot water heater for further installation information. SCREWS 1. Remove the two screws from the back of the water heater. Attach the bracket with the screws as shown in Figure 6a. 2. Hang t
Résumé du contenu de la page N° 12
Express® Lavatory System - MG-Series with TouchTime® Control MG-2/TT Installation Instructions Installation Instructions continued . . . Step 7: Connecting electrical and supply tubing WARNING: MG-2/TT must be connected to 24 VAC Class II plug-in transformer provided. Connection to 110 VAC may cause personal injury and/or damage to electronics. Connection of leads other than shown may cause permanent damage to the switch. 1. Insert the two sprayhead supply tubes into the two solenoid tube conne
Résumé du contenu de la page N° 13
Express® Lavatory System - MG-Series with TouchTime® Control Installation Instructions MG-2/TT Cleaning and Maintenance Instructions IMPORTANT: Strong alkaline or acid-based chemicals and cleansers should not be used to clean the MG-2/TT Express®. If these chemicals come in contact with the Terreon® surface, wipe off the surface immediately and flush with soapy water. Avoid unnecessary or prolonged contact with hot pans and objects. Terreon® and panel maintenance The bowl, sprayhead and pedesta
Résumé du contenu de la page N° 14
Express® Lavatory System - MG-Series with TouchTime® Control MG-2/TT Installation Instructions Assembly of Components SPRAYHEAD BODY (PART NUMBER VARIES WITH COLOR OF UNIT. CONTACT YOUR LOCAL BRADLEY REP. FOR ASSISTANCE). BOWL (PART NUMBER VARIES WITH COLOR OF UNIT. CONTACT YOUR LOCAL BRADLEY REP. FOR ASSISTANCE). END CAP (LEFT) (PART NUMBER VARIES WITH COLOR OF UNIT. CONTACT YOUR LOCAL BRADLEY REP. FOR ASSISTANCE). SPRAYHEAD MOUNTING BOLTS (3) END CAP (RIGHT) (PART NUMBER VARIES WITH CO
Résumé du contenu de la page N° 15
Express® Lavatory System - MG-Series with TouchTime® Control Installation Instructions MG-2/TT Assembly of Components continued . . . Sensor assembly and solenoid valve access • To access solenoids: Using a 5/32" Allen socket wrench, loosen, but do not remove the three bottom access panel screws. Remove the two top access panel screws and washers securing the panel to the frame and remove the access panel (see Figure 3 on page 8). Solenoids are located on left side of frame (see Figure 9). • To
Résumé du contenu de la page N° 16
Express® Lavatory System - MG-Series with TouchTime® Control MG-2/TT Installation Instructions Assembly of Components continued . . . TouchTime® and Aerator/Access Plate Assemblies SPACER 182-115 NUT 110-115 ACCESS PLATE 150-201 TOUCHTIME® SWITCH (15-SECOND) S83-139B ACCESS PLATE/AERATOR ASSEMBLY S05-166 1/4" CONNECTOR 145-089 AERATOR/HOUSING-FLOW SCREW-ALLEN SOCKET #10-24 CONTROL Figure 11 160-138 S05-142 Other replacement parts 110-24 VAC CLASS II PLUG-IN TRANSFORMER S83-134 16 2/8/07 Bradley
Résumé du contenu de la page N° 17
Express® Lavatory System - MG-Series with TouchTime® Control Installation Instructions MG-2/TT Troubleshooting Solenoid Valve (VAC) CAUTION: Turn off electrical and water supplies to unit before troubleshooting. Problem: An individual operating station fails to shut off and drips. Cause: There is debris trapped between the diaphragm and the valve seat. Solution: Remove debris between diaphragm and the valve seat. 1. Remove the three #8 Phillips-head screws that hold the solenoid valve assembly t
Résumé du contenu de la page N° 18
Express® Lavatory System - MG-Series with TouchTime® Control MG-2/TT Installation Instructions Solenoid Valve S07-067 (closed body) and S07-067A (thru body) REF. QTY. PART NO. DESCRIPTION 8 1 1 118-307 VALVE BODY, 1/4" CLOSED 1 1 118-307A VALVE BODY, 1/4" THRU 2 1 269-983 DIAPHRAGM 3 1 269-577 ARMATURE 4 1 269-578 SPRING 5 1 269-1729 ARMATURE HOUSING 7 6 1 269-1730 CLAMP, ARMATURE HOUSING 7 1 269-579 COIL, SOLENOID VALVE 8 3 160-447 SCREW, #8 X 5/8 8 9 1 125-165 O-RING, #2-013 6 5 4 3 2 1 9 Fig
Résumé du contenu de la page N° 19
Express® Lavatory System - MG-Series with TouchTime® Control Installation Instructions MG-2/TT Thermostatic Mixing Valve Maintenance and Troubleshooting NOTE: Before attempting to troubleshoot the valve or disassemble the components, check for the following conditions: • If stop/check valves are used, make sure that they are fully open. • Make sure that the hot and cold inlet pipes are connected properly, and that there are no cross-connections or leaking stop/check valves. • Check the hot wa
Résumé du contenu de la page N° 20
Express® Lavatory System - MG-Series with TouchTime® Control MG-2/TT Installation Instructions Vernatherm™ Thermostatic Mixing Valve (S01-524) Repair Kit S65-259 10 Nut 3/8-24 Hex Jam Item Qty Description 51 Thermostat 9 Cap 7 1 O-Ring 8 1 O-Ring 8 O-Ring 7 O-Ring 6 Stem 5 Thermostat 4 Piston 3 Spring 2 Seal Cup 1 Valve Body Strainer 11 (173-028) Figure 13 Tempered Line Adapter Assembly (S39-685) Option Figure 14 Strainer 173-028 20 2/8/07 Bradley Corporation • 215-1480 Rev. E; EN 06-915