Résumé du contenu de la page N° 1
Installation Guide
Wall/Ceiling Mount Faucet
K-922, K-923 K-924
M product numbers are for Mexico (i.e. K-12345M)
Los números de productos seguidos de
M corresponden a México (Ej.
K-12345M)
Français, page ″Français-1″
Español, página ″Español-1″
1006741-2-G
Résumé du contenu de la page N° 2
Tools and Materials Tape Measure Pencil Tape Silicone Level Measure Sealant Screwdrivers Plus: • 2x4 Lumber 1x3 Lumber Pipe Strap Adjustable Propane Wrench Torch Drill Solder Before You Begin Shut off the main water supply. Observe all local plumbing and building codes. Do not use this flow spout as a showerhead because it will cause excessive splashing and does not meet showerhead codes. This flow spout is available in two orifice sizes: 3/4″ (2 cm) and 15/16″ (2.4 cm). The smaller orifice s
Résumé du contenu de la page N° 3
Before You Begin (cont.) In applications where excessive air could enter the water supply, install an air separator. When a deck mounted transfer valve (K-408-K or K-409-K) is used for a ceiling mount, install a check valve between the spout and the diverter. Remove the mounting sleeve and cartridge before installing the spout body. Kohler Co. reserves the right to make revisions in the design of products without notice, as specified in the Price Book. Kohler Co. 3 1006741-2-G
Résumé du contenu de la page N° 4
7" (17.8 cm) Bath Bath Enter Offset Installation Center Installation 1. Determine the Location CAUTION:Risk of property damage. When employing a wall mount installation, install this spout at the end of the bathing fixture so the water stream projection stays within the bathing fixture. There are three recommended installation configurations for the spout: 1) offset wall mount, 2) center wall mount, and 3) ceiling mount. The offset wall mount is highly recommended for the safety of the user. Offset
Résumé du contenu de la page N° 5
One Bather Enter Ceiling Installation Range Two Bathers Enter 2. Ceiling Installation Layout Install the spout in the ceiling over the bathing fixture at the shaded areas shown in the illustration. Mount the spout so it is 9’ (2.7 m) or less from the bottom of the bathing fixture. Locate the spout so the water stream contacts the flat bottom of the bathing fixture. Excess splashing will occur if the water stream contacts whirlpool jets or bathing fixture corners. Kohler Co. 5 1006741-2-G
Résumé du contenu de la page N° 6
Backup Plate 2x4's Mounting Plate Install nut and washer. 5-5/8" (14.3 cm) Stud 2" (5.1 cm) Bathing Fixture Drywall or #10 Wood Screws 3. Install the Drip Tray Mounting Plate NOTE: The drip tray is an optional accessory available for wall mount but not for ceiling mount. NOTE: Install the 2x4’s so the drip tray is level or has a slight forward slope to ensure proper drainage. Attach a 2x4 flush to the back of the wall stud to support the lower lip of the drip tray mounting plate. Position
Résumé du contenu de la page N° 7
3/8" (1 cm) Valve Outlet Tubing 1x3 Pipe Strap 4" (10.2 cm) Intake 2x4 Pipe Spout Assembly 7-5/8" (19.4 cm) 4. Install the Spout – Wall Installation Install a 2x4 for spout support so it lays flush against the top support of the drip tray. If the drip tray is installed, the spout center must be 7-5/8″ (19.4 cm) from the drip tray mounting studs. If the drip tray is not installed, the spout center must be 14-16″ (35.6-40.6 cm) from the deck of the bathing fixture. NOTE: When 2x6 wall studs are pr
Résumé du contenu de la page N° 8
Install the Spout – Wall Installation (cont.) Solder the intake pipe to the valve outlet tubing. Secure the valve outlet tubing to the 1x3 using a pipe strap. 1006741-2-G 8 Kohler Co.
Résumé du contenu de la page N° 9
Back Plate 2x4 Screw 3-3/4" (9.5 cm) Spout Intake Pipe Assembly 5. Install the Spout – Ceiling Installation Install a 2x4 for support in the location where the spout will be mounted. Position the 2x4 support so it is 3-3/4″ (9.5 cm) from the bottom of the joist. Install the spout assembly to the 2x4 using two wood screws, inserted at the angles shown, through the holes in the back plate. Remove the boot cap from the end of the intake pipe. Remove the mounting sleeve and cartridge. Solder the in
Résumé du contenu de la page N° 10
Finished Add sealant Wall to groove. 3-3/8" D. (8.6 cm) (spout hole) 7-5/8" 1-1/2" (19.4 cm) (3.8 cm) Installed Spout 3" (7.6 cm) Mounting Mounting Sleeve 1/2" D. (1.3 cm) holes Plate (optional drip tray studs) 6. Complete the Installation Complete the finished wall and/or ceiling. If installing the optional drip tray, make sure the studs are positioned and tightened correctly. Apply silicone sealant to the groove in the flange of the mounting sleeve. Insert the mounting sleeve in the spo
Résumé du contenu de la page N° 11
Installed Mounting Sleeve Cartridge Assembly Orifice Screw O-Ring Decorative Flange 7. Assemble the Spout Slide the cartridge assembly onto the orifice O-ring until it fits snugly. Install the cartridge assembly/orifice into the mounting sleeve and align the holes. Install the three screws and tighten until the sleeve and orifice are tight against the wall. Thread the decorative flange clockwise into the orifice and hand-tighten until secure against the wall. Kohler Co. 11 1006741-2-G
Résumé du contenu de la page N° 12
Apply sealant. Stud Drip Tray Notch Setscrews 8. Install the Drip Tray and Screen Verify that the studs are positioned and tightened correctly. Apply a bead of silicone caulk sealant around the base of each drip tray mounting stud. Slide the drip tray onto the mounting stud until it is flush to the finished wall, and tighten with the two setscrews. To install the screen in the drip tray, locate the notch on the bottom edge of the screen. Align the notched end of the screen to the front edge of the
Résumé du contenu de la page N° 13
Guide d’installation Robinet à montage mural/plafond Outils et matériels Mètre Crayon à ruban papier Mètre Joint en Niveau à ruban silicone Tournevis bulle Plus: Madrier 2x4 Madrier 1x3 Sangle à tuyau Clé à Fer à souder Chalumeau Perceuse molette à propane Avant de commencer Couper l’alimentation d’eau principale. Respecter tous les codes de plomberie et de bâtiment locaux. Ne pas utiliser ce bec à débit laminaire comme vaporisateur de douche car celà entrainerait des éclaboussures ex
Résumé du contenu de la page N° 14
Avant de commencer (cont.) Un anti-coups de bélier est recommandé dans les applications de montage au plafond utilisant une valve montée de haut débit. Kohler recommande qu’un anti coups de bélier de type Sioux Chief 652-AD soit localisé près de la sortie de la valve. Contacter Sioux Chief au 1-800-821-3944 ou www.siouxchief.com. Pour des applications de montage au plafond, la hauteur de la base de la baignoire au bec ne devrait pas dépasser 9’ (2,7 m). Dans des applications où un débit d’air ex
Résumé du contenu de la page N° 15
7" (17,8 cm) Baignoire Baignoire Entrer Installation excentrée Installation centrée 1. Déterminer l’emplacement ATTENTION:Risque d’endommagement du matériel. Lorsque l’on réalise une installation sur mur, installer le bec à l’extrémité de la baignoire, de façon à ce que la projection du jet d’eau ne dépasse pas l’appareil de la baignoire. Ilyatrois types de configurations d’installations conseillées pour le bec: 1) montage mural excentré, 2) montage mural central, et 3) montage au plafond Le mont
Résumé du contenu de la page N° 16
Un baigneur Entrer Portée de l'installation au plafond Deux baigneurs Entrer 2. Plan d’installation au plafond Installer le bec au plafond au dessus de la baignoire aux emplacements indiqués en gris dans l’illustration. Monter le bec de manière à ce qu’il soit à un maximum de 9’ (2,7 m) de la base de la baignoire. Localiser le bec de façon que le jet d’eau se mette en contact avec la surface plate de la baignoire. Un éclaboussement excessif aura lieu si le courant d’eau se met en contact avec le
Résumé du contenu de la page N° 17
Plaque de fond 2x4 Plaque de fixation Installer l'écrou et la rondelle. 5-5/8" (14,3 cm) Montant 2" (5,1 cm) Baignoire Vis autoforeuse ou à bois No.10 3. Installer la plaque de fixation d’égouttement REMARQUE: Le récipient d’égouttement est un accessoire optionnel disponible pour une fixation murale et non au plafond. REMARQUE: Installer les montants de2x4de manière à ce que le récipient d’égouttement soit nivelé ou légèrement incliné vers l’avant afin d’assurer une bonne évacuation. Attacher
Résumé du contenu de la page N° 18
3/8" (1 cm) Tuyau de sortie de la valve 1x3 Sangle à tuyau 4" (10,2 cm) Tuyau 2x4 d'arrivée Ensemble du bec 7-5/8" (19,4 cm) 4. Installer le bec - Installation murale Installer un2x4 pour supporter le bec de manière à ce que celui-ci soit d’équerre contre le support supérieur du récipient d’égouttement. Si le récipient d’égouttement est installé, le centre du bec doit être à [7-5/8″ (19,4 cm)] des tiges de fixation du récipient d’égouttement. Si le récipient d’égouttement n’est pas installé,
Résumé du contenu de la page N° 19
Installer le bec - Installation murale (cont.) Mettre l’ensemble du bec en position. S’assurer que le bec et la plaque de fixation du récipient d’égouttement (si installée) soient centrés. Retirer le bouchon de l’extrémité du tuyau d’arrivée d’eau. Retirer le manchon de fixation et la cartouche. Souder le tuyau d’arrivée d’eau à la sortie de la valve. Sécuriser la tuyauterie de la sortie de la valve au1x3 avec une sangle à tuyau. Kohler Co. Français-7 1006741-2-G
Résumé du contenu de la page N° 20
Plaque de fond 2x4 Vis 3-3/4" (9,5 cm) Ensemble Tuyau du bec d'arrivée 5. Installer le bec - Installation au plafond Installer un2x4 pour support à l’emplacement d’installation du bec. Positionner le support de2x4à 3-3/4″ (9,5 cm) de la base de la solive. Installer l’ensemble du bec au2x4à l’aide de deux vis à bois, insérées sur les angles indiqués, à travers les orifices de la plaque de fond. Retirer le bouchon de l’extrémité du tuyau d’arrivée d’eau. Retirer le manchon de fixation et la carto