Résumé du contenu de la page N° 1
fx-100MS
fx-115MS (fx-912MS)
User’s Guide 2
(Additional Functions)
kfx-912MS owners
Please be sure to read the important notice of this manual.
E http://world.casio.com/edu_e/
Résumé du contenu de la page N° 2
Important! Please keep your manual and all information handy for future reference. CASIO ELECTRONICS CO., LTD. Unit 6, 1000 North Circular Road, London NW2 7JD, U.K.
Résumé du contenu de la page N° 3
Contents Before getting started... .......................... 2 kModes .................................................................... 2 Mathematical Expression Calculations and Editing Functions ............................ 3 kReplay Copy ........................................................... 3 kCALC Memory ....................................................... 4 kSOLVE Function .................................................... 4 Scientific Function Calculations............ 5 kInp
Résumé du contenu de la page N° 4
Before getting started... k Modes Before starting a calculation, you must first enter the correct mode as indicated in the table below. • The following table shows the modes and required operations for the fx-100MS and fx-115MS. fx-100MS and fx-115MS Modes To perform this type of Perform this To enter calculation: key operation: this mode: Basic arithmetic F 1 COMP calculations Complex number F 2 CMPLX calculations Standard deviation SD F F 1 Regression calculations REG F F 2 Base-n calculations
Résumé du contenu de la page N° 5
• Mode indicators appear in the upper part of the display, except for the BASE indicators, which appear in the exponent part of the display. • Engineering symbols are automatically turned off while the calculator is the BASE Mode. •You cannot make changes to the angle unit or other display format (Disp) settings while the calculator is in the BASE Mode. • The COMP, CMPLX, SD, and REG modes can be used in combination with the angle unit settings. •Be sure to check the current calculation mode (SD
Résumé du contenu de la page N° 6
•You can also edit expressions on the display and per- form other multi-statement operations. For more details about using multi-statements, see “Multi-statements” in the separate “User’s Guide.” • Only the expressions in replay memory starting from the currently displayed expression and continuing to the last expression are copied. Anything before the displayed expression is not copied. COMP CMPLX k CALC Memory • CALC memory lets you temporarily store a mathematical expression that you need to
Résumé du contenu de la page N° 7
Use the formula below to calculate initial velocity A for a height of B = 14 meters and a time of C = 2 seconds. 2 Gravitational acceleration is D = 9.8 m/s . (Result: A = 16.8) 1 2 B AC – DC 2 p 2 p u p 1 - p k , R 1 \ 2 T - p h - p k K A I (B?) 14 = (A?) ] (C?) 2 = (D?) 9 l 8 = [ [ (A?) A I • The SOLVE function finds approximations based on Newton’s method, which means that error can occur. Certain expressions or initial values may result in error without convergence of results. • If a
Résumé du contenu de la page N° 8
•To turn engineering symbols on and off, press the F key a number of times until you reach the setup screen shown below. Disp 1 •Press 1. On the engineering symbol setting screen that appears, press the number key ( 1 or 2) that corre- sponds to the setting you want to use. 1(Eng ON): Engineering symbols on (indicated by “Eng” on the display) 2(Eng OFF): Engineering symbols off (no “Eng” indicator) • The following are the nine symbols that can be used when engineering symbols are turned on. To
Résumé du contenu de la page N° 9
A P 0.9 9 1 m J 900. Complex Number CMPLX Calculations Use the F key to enter the CMPLX Mode when you want to perform calculations that include complex numbers. CMPLX ........................................................... F 2 • The current angle unit setting (Deg, Rad, Gra) affects CMPLX Mode calculations. You can store an expres- sion in CALC memory while in the CMPLX Mode. • Note that you can use variables A, B, C, and M only in the CMPLX Mode. Variables D, E, F, X, and Y
Résumé du contenu de la page N° 10
k Absolute Value and Argument Calculation Supposing the imaginary number expressed by the rectangular form z = a + bi is represented as a point in the Gaussian plane, you can determine the absolute value (r) and argument () of the complex number. The polar form is r. • Example 1: To determine the absolute value (r) and argument () of 3+4i (Angle unit: Deg) (r = 5, = 53.13010235°) Imaginary axis Real axis (r 5) A A R 3 + 4 i T = ( 53.13010235°) A a R 3 + 4 i T = • The complex number ca
Résumé du contenu de la page N° 11
•You select rectangular form (a+bi) or polar form (r) for display of complex number calculation results. ... F 1(Disp) r 1(a+bi):Rectangular form 2(r): Polar form (indicated by “r ” on the display) k Conjugate of a Complex Number For any complex number z where z = a+bi, its conjugate (z) is z = a–bi. • Example: To determine the conjugate of the complex number 1.23 + 2.34i (Result: 1.23 – 2.34i) A S R 1 l 23 + 2 l 34 i T = A r BASE Base-n Calculations Use the F key to enter the BASE Mode w
Résumé du contenu de la page N° 12
•You can use the following logical operators between values in Base-n calculations: and (logical product), or (logical sum), xor (exclusive or), xnor (exclusive nor), Not (bitwise complement), and Neg (negation). • The following are the allowable ranges for each of the available number systems. Binary 1000000000 x 1111111111 0 x 0111111111 Octal 4000000000 x 7777777777 0 x 3777777777 Decimal –2147483648 x 2147483647 Hexadecimal 80000000 x FFFFFFFF 0 x 7FFFFFFF • Examp
Résumé du contenu de la page N° 13
• Example 4: To convert the value 22 to its binary, oc- 10 tal, and hexadecimal equivalents. (10110 , 26 , 16 ) 2 8 16 b Binary mode: t b 0. b 10110. l l l 1(d) 22 = o 26. Octal mode: o H Hexadecimal mode: h 16. • Example 5: To convert the value 513 to its binary 10 equivalent. b 0. Binary mode: t b Mt a h ERROR l l l 1(d) 513 = b •You may not be able to convert a value from a number system whose calculation range is greater than the cal- culation range of the resulting number system. • The mes
Résumé du contenu de la page N° 14
•Input a value from 1 to 4 to select the probability distribution calculation you want to perform. P(t)R Q(t)(t) • Example: To determine the normalized variate (→t) for x = 53 and normal probability distribution P(t) for the following data: 55, 54, 51, 55, 53, 53, 54, 52 (→t = 0.284747398, P(t) = 0.38974 ) 55 S 54 S 51 S 55 S 53 S S 54 S 52 S 53 A D 4(→t) = A D 1( P( ) D 0.28 F = Differential COMP Calculations The procedure described below obtains the derivative of a function. Use the F key to
Résumé du contenu de la page N° 15
•You can omit input of ∆ x, if you want. The calculator automatically substitutes an appropriate value for ∆ x if you do not input one. •Discontinuous points and extreme changes in the value of x can cause inaccurate results and errors. Integration COMP Calculations The procedure described below obtains the definite integral of a function. Use the F key to enter the COMP Mode when you want to perform integration calculations. COMP ............................................................F 1 •
Résumé du contenu de la page N° 16
Power Supply The type of battery you should use depends on the model number of your calculator. fx-115MS The TWO WAY POWER system actually has two power supplies: a solar cell and a G13 Type (LR44) button battery. Normally, calculators equipped with a solar cell alone can operate only when relatively bright light is present. The TWO WAY POWER system, however, lets you continue to use the calculator as long as there is enough light to read the display. •Replacing the Battery Either of the followi
Résumé du contenu de la page N° 17
fx-100MS This calculator is powered by a single AA-size battery. •Replacing the Battery Dim figures on the display of the calculator indicate that battery power is low. Continued use of the calculator when the battery is low can result in improper operation. Replace the battery as soon as possible when display figures become dim. • To replace the battery 1 Press A i to turn power off. Screw Screw 2 Remove the six screws that hold the back cover in place and then remove the back cover. 3 Remove t
Résumé du contenu de la page N° 18
Specifications Power Supply: fx-100MS: Single AA-size battery (R6P(SUM-3)) fx-115MS: Solar cell and a single G13 Type button battery (LR44) Battery Life: fx-100MS: Approximately 17,000 hours continuous display of flashing cursor. Approximately 2 years when left with power turned off. fx-115MS: Approximately 3 years (1 hour use per day). Dimensions: fx-100MS: 20.0 (H) 78 (W) 155 (D) mm 13 1 1 /16 (H) 3 /16 (W) 6 /8 (D) fx-115MS: 12.7 (H) 78 (W) 154.5 (D) mm 1 1 1 /2 (H) 3 /16 (
Résumé du contenu de la page N° 19
CASIO COMPUTER CO., LTD. 6-2, Hon-machi 1-chome Shibuya-ku, Tokyo 151-8543, Japan SA0206-D Printed in China CA 310074C-1