Résumé du contenu de la page N° 1
INSTALLATION INSTRUCTIONS
24" (61.0 CM) GAS SINGLE
AND DOUBLE BUILT-IN OVEN
Table of Contents
BUILT-IN OVEN SAFETY ................................ 1
INSTALLATION REQUIREMENTS ................. 3
Tools and Parts ............................................. 3
Location Requirements................................. 3
Electrical Requirements ................................ 4
Gas Supply Requirements ............................ 5
INSTALLATION INSTRUCTIONS ................... 6
Prepare Built-In Ove
Résumé du contenu de la page N° 2
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. – Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. – WHAT TO DO IF YOU SMELL GAS: Do not try to light any appliance. • Do not touch any electrical switch. Do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier'
Résumé du contenu de la page N° 3
INSTALLATION REQUIREMENTS Product Dimensions - Single Oven Tools and Parts Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed A here. Tools needed ■ Tape measure ■ Marker or pencil ■ Phillips screwdriver ■ Pipe-joint compound resistant to LP gas B ■ Flat-blade screwdriver E ■ ³⁄₁₆" (4.8 mm) carbide-tipped ■ ¹⁄₈" Flat-blade screwdriver masonry drill bit (for concrete/ceramic floors) ■ Level ■ Noncorrosive leak-det
Résumé du contenu de la page N° 4
Product Dimensions - Double Oven Cabinet Side View - Double or Single Oven A A B B E C D E A. 24" (61 cm) min. cutout depth B. 22⁵⁄₈" (57.5 cm) recessed oven depth C. Oven front D. Recessed oven E. Cabinet C D Electrical Requirements A. 22¹⁄₄" (56.8 cm) max. recessed width B. 46⁵⁄₁₆" (117.6 cm) max. overall height WARNING C. 23⁷⁄₈" (60.6 cm) overall width D. 22⁵⁄₈" (57.5 cm) max. recessed depth E. 44³⁄₄" (113.4 cm) recessed height Cabinet Dimensions - Double Oven Double Oven Installed in Cabinet
Résumé du contenu de la page N° 5
■ A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is LP gas conversion: required. A time-delay fuse or circuit breaker is also Conversion must be done by a qualified service technician. recommended. It is recommended that a separate circuit No attempt shall be made to convert the appliance from the gas serving only this oven be provided. specified on the model/serial rating plate for use with a different ■ Electronic ignition systems operate within wide voltage limits, gas wi
Résumé du contenu de la page N° 6
For elevations above 2,000 ft (609.6 m), the burner should be Gas Pressure Regulator reduced 4% for each 1,000 ft (304.8 m) above sea level (not applicable for Canada). The gas pressure regulator supplied with this oven must be used. The inlet pressure to the regulator should be as follows for proper Gas Supply Pressure Testing operation: Natural gas: Gas supply pressure for testing regulator must be at least 1" water column pressure above the manifold pressure shown on Minimum pressure:
Résumé du contenu de la page N° 7
3. Use a ¹⁵⁄₁₆" combination wrench and an adjustable wrench to Complete connection attach the flexible connector to the adapters. Check that 1. Open the manual shutoff valve in the gas supply line. The connector is not kinked. valve is open when the handle is parallel to the gas pipe. A A B B A. Closed valve C B. Open valve 2. Test all connections by brushing on an approved noncorrosive leak-detection solution. If bubbles appear, a leak is indicated. D Correct any leak found. H G E WARN
Résumé du contenu de la page N° 8
3. Securely fasten oven to cabinet using the 0.188 x 2.1" screws 4. Replace oven racks. (4 for single oven, 6 for double oven) provided. Insert the 5. Grasp sides of the door and align slots in door with the hinge screws through holes in decorative trim. To avoid cabinet arms. damage, use the 0.140" diameter (number 28) drill bit to pre- drill the pilot holes before driving screws. Do not overtighten 6. Slightly pull the door open as you slide the door down onto the hinge arms. The sliding
Résumé du contenu de la page N° 9
GAS CONVERSIONS Gas conversions from Natural gas to LP gas or from LP gas to Natural gas must be done by a qualified installer. To Convert Gas Pressure Regulator 1. Locate gas pressure regulator in bottom compartment. WARNING A B C G Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column. Examples of a qua
Résumé du contenu de la page N° 10
3. Flip the regulator pin over and snap pin firmly into place. Natural Gas Conversion 1. Turn manual shutoff valve to the closed position. 2. Unplug oven or disconnect power. A B A B C A. Natural gas position A. To oven B. LP gas position B. Shutoff valve (closed position) C. Gas supply line 4. Screw the hex-shaped regulator cap securely back into place. Do not overtighten. To Convert Gas Pressure Regulator To Convert Bake/Broiler Burner 1. Locate gas pressure regulator in bottom compartment. 1
Résumé du contenu de la page N° 11
2. Unscrew the hex-shaped regulator cap from the regulator and 4. Screw the hex-shaped regulator cap securely back into place. remove the regulator pin. Do not overtighten. A To Convert Oven Bake/Broil Burner 1. Remove racks from inside the broiler cavity. 2. Screw the burner orifice hood away from the pins. There will be approximately 1¹⁄₂ to 2 turns. A B A. Regulator pin B. Regulator cap 3. Flip the regulator pin over and snap pin firmly into place. B A. Burner orifice hood A NOTE: On units
Résumé du contenu de la page N° 12
W10203509A © 2008. Whirlpool Corporation. 7/08 All rights reserved. Printed in U.S.A.