wiring diagrams
558F
SINGLE PACKAGE ROOFTOP
036-150
ELECTRIC COOLING
1
3 to 12 / Tons
2
UNITS
Cancels: New WD 558F.36.1
11/15/00
DIAGRAM INDEX
UNIT LABEL DIAGRAM
Unit 558F Voltage-Phase-Hertz Type Label Diagram Figure No.
208/230-1-60 Schematic/Component Arrangement 50DK508524 1
208/230-3-60 Schematic/Component Arrangement 50DK508526 2
036,048
460-3-60 Schematic/Component Arrangement 50DK508529 3
575-3-60 Schematic/Component Arrangement 50DK508531 4
208/230-1-60 Schematic/Component Arrangement 5
Résumé du contenu de la page N° 2
NOTES FOR FIG. 1, 2, 5, 6, 9 1. If any of the original wire furnished must be replaced, it must be 4. Set heat anticipator at 1 amp. replaced with Type 90 C wire or its equivalent. 5. Use copper conductors only. 2. Three-phase motors are protected under primary single-phasing 6. Use copper, copper-clad aluminum or aluminum conductors. conditions. 7. For 208/230-3-60 v units: TRAN is wired for 230-v unit. If unit is to be 3. Thermostat: run with 208-v power supply, disconnect BLK wire from 230-v
Résumé du contenu de la page N° 3
Fig. 1 — Schematic/Component Arrangement; 558F036,048; 208/230-1-60 —3—
Résumé du contenu de la page N° 4
Fig. 2 — Schematic/Component Arrangement; 558F036,048; 208/230-3-60 —4—
Résumé du contenu de la page N° 5
Fig. 3 — Schematic/Component Arrangement; 558F036,048; 460-3-60 —5—
Résumé du contenu de la page N° 6
Fig. 4 — Schematic/Component Arrangement; 558F036,048; 575-3-60 —6—
Résumé du contenu de la page N° 7
Fig. 5 — Schematic/Component Arrangement; 558F060; 208/230-1-60 —7—
Résumé du contenu de la page N° 8
Fig. 6 — Schematic/Component Arrangement; 558F060; 208/230-3-60 —8—
Résumé du contenu de la page N° 9
Fig. 7 — Schematic/Component Arrangement; 558F060; 460-3-60 —9—
Résumé du contenu de la page N° 10
Fig. 8 — Schematic/Component Arrangement; 558F060; 575-3-60 —10—
Résumé du contenu de la page N° 11
Fig. 9 — Schematic/Component Arrangement; 558F072; 208/230-3-60 and 460-3-60 —11—
Résumé du contenu de la page N° 12
Fig. 10 — Schematic/Component Arrangement; 558F072; 575-3-60 —12—
Résumé du contenu de la page N° 13
—13— Fig. 11 — Schematic/Component Arrangement; 558F090-150; 208/230-3-60 and 460-3-60
Résumé du contenu de la page N° 14
—14— Fig. 12 — Schematic/Component Arrangement; 558F090-150; 575-3-60
Résumé du contenu de la page N° 15
558F036-072 LEGEND C — Contactor 558F090-150 Fig. 13 — Motormaster® I Wiring Details LEGEND C— Contactor OFC — Outdoor-Fan Contactor TRAN — Transformer NOTE: Motormaster II transformer is wired for 460-v supply; it must be rewired for 208/230-v application. Be sure to insulate unused tap. Refer to color code. Fig. 14 — Motormaster II Wiring Schematic; 558F036-072 —15—
Résumé du contenu de la page N° 16
LEGEND C— Contactor OFC — Outdoor-Fan Contactor TRAN — Transformer *The Motormaster II head pressure controller is equipped with an alternate operating mode. When this mode is selected, the controller shifts the fan cycle sequence to effectively raise the average condensing temperature approximately 20 F higher than the standard operating mode. In this alternate mode, the outdoor fan begins cycling at higher outdoor ambient temperatures. This mode should only be used if the evaporator coil shows
Résumé du contenu de la page N° 17
BRN TIME GUARD I I DEVICE BRN 2 T1 T2 1 3 T3 CLO C COMPRESSOR OR SAFETIES CR 1 HIGH EFFICIENCY 3 TO 12 / TON ROOFTOP UNITS 2 BRN TIME GUARD I I DEVICE T1 T3 T2 C OR CR 1 STANDARD EFFICIENCY 3 TO 12 / TON ROOFTOP UNITS 2 LEGEND C — Contactor CLO — Compressor Lockout CR — Control Relay Fig. 16 — Time Guard® II Device; 558F036-150 24 VAC SUPPLY FROM 24 VAC SUPPLY FROM ECONOMIZER CONTROL ECONOMIZER CONTROL } SECTION (RED TO TR, SECTION (RED TO TR, TR1 TR BRN TO TR1) BRN TO TR1) B B TR TR1 A C C
Résumé du contenu de la page N° 18
LEGEND OAT — Outdoor-Air Thermostat Fig. 19 — EconoMi$er Wiring ECONOMI$ER BROWN TEMP CONTROLLER VIOLET TEMP OUTDOOR AIR OAT COM SENSOR WHITE COM OUT RED PWR OAH -15 V BROWN RAT TEMP VIOLET RETURN TEMP COM AIR WHITE COM SENSOR RAH OUT RED +15 V PWR CO SENSOR 2 (+) V+ 24 CO 2 CO2 COM COM VAC DAT COM SUPPLY AIR TEMPERATURE SENSOR REM POT PINK COM TEMP LED VIOLET TEMP COM Fig. 20 — EconoMi$er Sensor Wiring; 558F036-150 —18—
Résumé du contenu de la page N° 19
TO FUSED DISCONNECT RED GRAY RED YEL BLU GRAY H1 H2 H1 H3 H2 H4 X4 X2 X3 X1 X4 X2 X3 X1 FIELD SUPPLIED WIRING SECONDARY SECONDARY 230VAC 230VAC BLACK BLACK COMPRESSOR 1 OR CONTACTOR LT. BLUE 3 B 11 21 6 9 230VAC BROWN BLACK 13 23 FAN 1 R1 3-PIN 2 5 8 24 VAC C1 CONNECTOR GREEN/ PLUG YELLOW 1 4 7 A 4-PIN CONNECTOR 2 x 4 IN. BLUE ORANGE 1 PLUG HANDY BOX YELLOW L1 2 BLACK L1 1 1 L2 BLUE L2 BROWN 22 3 GREEN GND GND 33 BLACK BLACK 44 BLUE 230 VAC LT. BLUE GREEN 1 PHASE 3 6 9 B BLACK R2 BROWN F
Résumé du contenu de la page N° 20
Copyright 2000 Bryant Heating & Cooling Systems CATALOG NO. 5355-810