Résumé du contenu de la page N° 1
ATM/POS bridge
Installation Manual
EN
Résumé du contenu de la page N° 2
ATM/POS bridge | Installation Manual ii Bosch Security Systems
Résumé du contenu de la page N° 3
ATM/POS bridge | Installation Manual iii ATM/POS Bridge Installation manual Bosch Security Systems
Résumé du contenu de la page N° 4
ATM/POS bridge | Installation Manual iv IMPORTANT SAFETY INSTRUCTIONS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with a dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat
Résumé du contenu de la page N° 5
ATM/POS bridge | Installation Manual v 13. Unplug this unit during lightning storms or when unused for long periods of time. 14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moistue, does not operate normally, or has been dropped. CAUTION This unit has a batte
Résumé du contenu de la page N° 6
ATM/POS bridge | Installation Manual vi Bosch Security Systems
Résumé du contenu de la page N° 7
ATM/POS bridge | Installation Manual EN | 1 ATM/POS bridge Table of Contents 1. ATM/POS bridge ................................................................................................... 3 1.1 Package contents...................................................................................... 3 1.2 Supported protocols................................................................................. 3 1.3 Mounting........................................................................
Résumé du contenu de la page N° 8
English ATM/POS bridge | Installation Manual EN | 2 SAFETY PRECAUTIONS CAUTION RISK OF ELECTRIC SHOCK. DO NOT OPEN! CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT OPEN COVERS. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This label may appear on the bottom of the unit due to space limitations. The lightning flash with an arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous vo
Résumé du contenu de la page N° 9
ATM/POS bridge | Installation Manual EN | 3 1. ATM/POS bridge The ATM/POS bridge connects a Point-of-Sale (POS) or an Automatic Teller Machine (ATM) to a Bosch digital video recorder so that transactional data from these units can be stored and displayed with associated video recordings. 1.1 Package contents Check the package for following items: •ATM/POS bridge • External DC power supply • Mounting kit • 2 connection cables and 1 console cable (with two 9-pole SubD connectors) • Installat
Résumé du contenu de la page N° 10
English ATM/POS bridge | Installation Manual EN | 4 1.4 Applications The following illustration shows an example of how a bridge is used in a network of digital video recoders and POS terminals. The following illustration shows an example of how a bridge is used in a network of digital video recoders and ATM terminals. Bosch Security Systems
Résumé du contenu de la page N° 11
ATM/POS bridge | Installation Manual EN | 5 1.5 Connections Using the supplied cables, connect the bridge as follows: 1. Connect the supplied DC power adapter unit to the DC power input connector of the bridge. 2. Connect the RJ45 connector of the bridge via a straight Ethernet CAT5 network cable to a network switch or hub that supports 10BaseT. Alternatively, the bridge can be connected directly to the digital video recorder via a cross-over cable. 3. To configure the bridge, use an RS232
Résumé du contenu de la page N° 12
English ATM/POS bridge | Installation Manual EN | 6 4. Connect your terminal to COM port 1, 2, 3 or 4 of the bridge using the supplied cable. Choose the COM 4 port on the bridge if your connection protocol is RS485. Normally, you would use the supplied splitter cable to make this connection. For example, you remove the existing cable that connects your terminal to the printer. Use the supplied splitter cable to connect the terminal to the printer. The third connector of the splitter cab
Résumé du contenu de la page N° 13
ATM/POS bridge | Installation Manual EN | 7 2. Configuration The ATM/POS bridge is configured via a PC HyperTerminal session. The PC is connected via a COM serial port to the COM 3 (console) port of the bridge. Start a HyperTerminal session on the PC to get access to the configuration menu of the bridge. 2.1 How to set up a HyperTerminal session 1. Start the PC HyperTerminal program in Windows (normally available under Start_Programs_Accessories_Communications). 2. Enter a name for the Hyp
Résumé du contenu de la page N° 14
English ATM/POS bridge | Installation Manual EN | 8 5. If the bridge is switched on, a welcome message is shown on the screen. This message prompts you to press the F1 key (a function key on your keyboard). 6. Press the F1 key; the screen displays the System Options Menu. 7. To configure the bridge, navigate through the menus using the numeric keys on your keyboard to select menu items. 2.2 Configuration menus 2.2.1 System options menu The system options menu has 6 items: 1. Network Setup
Résumé du contenu de la page N° 15
ATM/POS bridge | Installation Manual EN | 9 Communication Channels In the Communication Channels submenu you can select one of the four COM ports to configure. The submenu that appears depends on the setting of the Comport Mode. Enter the parameters that are required for your terminal. 1Comport Mode Asynchronous 3 Baudrate 9600 4 Databits 8 bits 5Parity None 6 Stop bits 1bit 7Flow Control Off Terminal Setup In the Terminal Setup submenu you can select one of the four connected terminals to
Résumé du contenu de la page N° 16
English ATM/POS bridge | Installation Manual EN | 10 Recording Language Select the same language that is set on the connected digital recorder. This ensures that characters are displayed correctly. The configuration menu language continues to be English. Service Menu The Service Menu is used to restore the bridge to factory defaults, to reset the bridge, or to do diagnostics. Bosch Security Systems
Résumé du contenu de la page N° 17
ATM/POS bridge | Installation Manual EN | 11 3. Connectors The four COM connectors are all 9-pin SubD-type male connectors. 5 1 6 9 The following table lists the signals and pin numbers for the four ports. COM 3 COM 1 COM 2 COM 4 Pin (console) RS 232 RS 232 RS 485 RS 232 1 2RxRxRxD2+ 3TxTx TxD2- 4 5 GND GND GND GND 6 7 RxC RxC 8 TxC TxC 9 INIT Bosch Security Systems English
Résumé du contenu de la page N° 18
English ATM/POS bridge | Installation Manual EN | 12 4. Troubleshooting If you are unable to capture transaction data, perform the following steps: 1. Recheck your cables. 2. Check your TCP/IP network connection with the ATM/POS bridge. Check your gateway and subnet mask settings, they must match the digital recorder settings. 3. If the recorder has established communication with your bridge and you still cannot capture the transaction data, use the simulation mode of the bridge in the Sys
Résumé du contenu de la page N° 19
ATM/POS bridge | Installation Manual EN | 13 5. Technical specifications Electrical Power supply: External DC power supply (supplied) Input: 100-240 VAC; 150mA, 50/60Hz Output: 12 VDC; 450mA Connector: DC jack, positive center pin; 10-30 VDC; 2W Mechanical Dimensions: 152 x 110 x 35 mm / 5.98 x 4.33 x 1.38 inch Weight: Approx. 0.6 kg / 1.3 lbs Mounting kit: Supplied Interface Ethernet: RJ45 shielded, 10 BaseT Com 1 port: 9-pin SUBD male connector; RS232 synchronous or asynchronous signals ac
Résumé du contenu de la page N° 20
English ATM/POS bridge | Installation Manual EN | 14 Electromagnetic Compatibility EMC requirements: USA: FCC Part 15, Class B EU: EMC directive 89/336/EEC Immunity: EN50130-4 Emission: EN55022 Class B Harmonics: EN61000-3-2 Voltage fluctuations: EN61000-3-3 Safety: USA: UL60950 EU: EN60950 Canada: CAN/CSA - C22.2 - 60950-00 Bosch Security Systems