Résumé du contenu de la page N° 1
Modicon Quantum Ethernet
Web Embedded Server
Module User Guide
840 USE 115 00 Version 1.0
Résumé du contenu de la page N° 2
Data, Illustrations, Alterations Data and illustrations are not binding. We reserve the right to alter products in line with our policy of continuous product development. If you have any suggestions for improvements or amendments or have found errors in this publication, please notify us using the form on one of the last pages of this publication. Training Schneider Automation Inc. offers suitable further training on the system. Hotline See addresses for Technical Support Centers at the end of
Résumé du contenu de la page N° 3
Modicon Quantum Ethernet Web Embedded Server Module User Guide 840 USE 115 00 Vesion 1.0 October, 1998
Résumé du contenu de la page N° 4
Document Set Quantum Automation Series Hardware Reference Guide 840 USE 100 00, Version 6.0 Modicon Quantum Ethernet TCP/IP Module User Guide 840 USE 107 00, Version 3.0
Résumé du contenu de la page N° 5
Preface The data and illustrations found in this book are not binding. We reserve the right to modify our products in line with our policy of continuous product development. The information in this document is subject to change without notice and should not be y Schneider Automation, Inc. construed as a commitment b Schneider Automation assumes no responsibility for any errors that may appear in this document. If you have any suggestions for improvements or amendments or y us. have found er
Résumé du contenu de la page N° 6
iv 840 USE 115 00 Version 1.0
Résumé du contenu de la page N° 7
Contents About This Book ............................................................................................. 1 Document Scope .............................................................................................. 1 Validity Note ..................................................................................................... 2 Related Documentation .................................................................................... 2 Chapter 1 Introduction ................
Résumé du contenu de la page N° 8
Contents 2.4.1 Selecting the Ethernet Framing Type ............................................................. 21 2.4.2 Assigning a Slot Number ................................................................................ 21 2.4.3 Assigning the IP Network Address ................................................................. 22 2.4.4 Assigning the Default Gateway Address and Subnet Mask ........................... 22 2.4.5 Resetting the Module ........................................
Résumé du contenu de la page N° 9
Contents 6.1.8 Application LED ............................................................................................. 57 6.1.9 Reading and Clearing the Error Log .............................................................. 57 6.2 Hot Swapping An Ethernet Module ................................................................ 60 6.3 Downloading a New Software Image ............................................................. 61 Appendix A Specifications ...............................
Résumé du contenu de la page N° 10
Contents viii 840 USE 115 00 Version 1.0
Résumé du contenu de la page N° 11
About This Book Document Scope This manual will acquaint you with the Quantum Ethernet web embedded server modules and their parts, tell you how to install them, describe changes you may make in configuration, review the operation of the modules and provide maintenance procedures. It also describes how to obtain statistics about the embedded server module and its controller from the embedded World Wide Web site. For details regarding the information available on the web site, please refer
Résumé du contenu de la page N° 12
About This Book Validity Note For the Ethernet web embedded server module to work properly, you must have the proper version of other system components. Use the version specified in the table below or a later version. Quantum Embedded Server Firmware Modsoft Concept ModLink Version 1.1 2.6 2.1 2.0 Related Documentation The following manuals may also be helpful. Be sure to order the version specified or a later version. z Modicon TSX Quantum Automation Series Hardware Reference Guide 840 U
Résumé du contenu de la page N° 13
Introduction 1 1.1 Ethernet Web Embedded Server Modules The Quantum Ethernet Web embedded server modules make it possible for a Quantum industrial control system to communicate with devices on an Ethernet network. For example, the modules can be used to link a Quantum Automation Series controller to a PC. Each module contains a World Wide Web server, which allows users to obtain statistics about the NOE module and its controller from an embedded web site. The Ethernet network is well supp
Résumé du contenu de la page N° 14
Introduction 1.1.2 Models for Fiber Optic and Twisted Pair Cable Systems Modicon has designed two Ethernet web embedded server modules: one for fiber optic networks and the other for networks using twisted pair cabling. Both are covered in this manual. Type of Cable Network Part Number Twisted Pair 140 NOE 211 10 Fiber Optic 140 NOE 251 10 4 840 USE 115 00 Version 1.0
Résumé du contenu de la page N° 15
Introduction 1.2 Front Panel Components On the front panel of each Ethernet embedded web server module, you will find an LED display, a global address label and a cable connector. Model Number 140 NOE 211 10 Module Description Ethernet TCP/IP Active Color Code Ready Fault Run Coll Link LED Display Removable Door Kernel Global Address Label Cable Connector Figure 1 140 NOE 211 10 Ethernet Web Embedded Server Module for Twisted Pair Networks 840 USE 115 00 Version 1.0 5
Résumé du contenu de la page N° 16
Introduction Model Number 140 NOE 251 10 Module Description Ethernet TCP/IP Active Color Code Ready Fault Run Coll Link LED Display Removable Door Kernel Global Address Label Transmit Cable Connector Receive Cable Connector Figure 2 140 NOE 251 10 Ethernet Web Embedded Serve Module for Fiber Optic Networks 6 840 USE 115 00 Version 1.0
Résumé du contenu de la page N° 17
Introduction 1.2.1 LED Display 140 NOE 211 10 Ethernet TCP/IP Active Ready Fault Run Coll Link Kernel Appl Figure 3 LED Display LED Color Indication When On Active Green Module is communicating with backplane. Ready Green Module has passed internal diagnostic tests. Run Green Flashes during normal operation. Link Green Ethernet link to hub is ok. If steady, module is operating in kernel mode. If Kernel Amber flashing, module is waiting for download. An error has been detected, a download h
Résumé du contenu de la page N° 18
Introduction 1.2.2 Address Labels Each Quantum Ethernet web embedded server module has two address labels. One identifies the Ethernet or MAC address. The other label allows you to record the module’s Internet Protocol (IP) network address. Ethernet The Ethernet address or MAC address is assigned at the factory and is recorded Address Label on a label on the front panel, above the cable connector. This is a unique 48-bit global assigned address. It is set in PROM. The Ethernet address is rec
Résumé du contenu de la page N° 19
Introduction Example Calculating the Derived IP Network Address Locate the global address label on the IEEE GLOBAL ADDRESS front panel of the module. 0000540B72A8 Note the rightmost eight digits. 5 4 0 B 7 2 A 8 Convert them from hexadecimal to decimal. Each pair of hexadecimal numbers will result in a decimal 8 4 . 1 1 . 1 1 4 . 1 6 8 number between 0 and 255. This is the derived IP address. Note: When you have determined which IP network address you will be using, r
Résumé du contenu de la page N° 20
Introduction 1.2.3 Twisted Pair Connector 8 Pins 1 Figure 5 NOE 211 Connector For the NOE 211, Schneider Automation recommends that you use Category 5 UTP cabling, which is rated to 100 Mbps, with an RJ-45 connector. You may also use Category 3 UTP cabling, which is rated to 16 Mbps. The eight pins are arranged vertically and numbered in order from the bottom to the top. The RJ-45 pinout used by this module is: z Receive Data (+) 3 z Receive Data (-) 6 z Transmit Data (+) 1 z Transmit Data (-