Résumé du contenu de la page N° 1
OnSite 1052 &1063 Series
Metro-Optical Transport
Access Nodes
Getting Started Guide
The compliance information in this document is incomplete and subject to change.
IMPORTANT
Sales Office: +1 (301) 975-1000
Technical Support: +1 (301) 975-1007
E-mail: support@patton.com
WWW: www.patton.com
Part Number: 07MOS10xx-GS, Rev. A
Revised: November 20, 2009
Résumé du contenu de la page N° 2
Patton Electronics Company, Inc. 7622 Rickenbacker Drive Gaithersburg, MD 20879 USA Tel: +1 (301) 975-1000 Fax: +1 (301) 869-9293 Support: +1 (301) 975-1007 Web: www.patton.com E-mail: support@patton.com Copyright © 2009, Patton Electronics Company. All rights reserved. The information in this document is subject to change without notice. Patton Electronics assumes no liability for errors that may appear in this document. The software described in this document is furnished under a license
Résumé du contenu de la page N° 3
Summary Table of Contents 1 Product Overview.......................................................................................................................................... 14 2 Application Overview.................................................................................................................................... 18 3 Installation Overview ................................................................................................................................
Résumé du contenu de la page N° 4
Table of Contents Summary Table of Contents ........................................................................................................................... 3 Table of Contents ........................................................................................................................................... 4 List of Figures ...............................................................................................................................................
Résumé du contenu de la page N° 5
OnSite Series Getting Started Guide OnSite System Installation ....................................................................................................................................29 Mounting the Chassis to an EIA/TIA 19-Inch Rack .......................................................................................29 Mounting the Chassis to an ETSI Rack ..........................................................................................................30 Mou
Résumé du contenu de la page N° 6
OnSite Series Getting Started Guide Model OS1052......................................................................................................................................................60 Trunk Interfaces .............................................................................................................................................60 Client Interfaces ...............................................................................................................
Résumé du contenu de la page N° 7
List of Figures 1 OnSite Model 1052 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2 OnSite Model 1063 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3 OS1052 Base System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Résumé du contenu de la page N° 8
List of Tables 1 General conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 2 Mouse conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 3 Base System Configuration for OnSite Platforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 4 Enviro
Résumé du contenu de la page N° 9
About this guide This guide describes how to install a Patton OnSite Series Model 1052 and1063 Metro-Optical Transport Access Node. For detailed configuration and management instructions, refer to the OnSite 1052 & 1063 Series Administrator’s Reference Guide, which is located on the CD-ROM that came with your unit and at www.pat- ton.com. Installation, maintenance, and removal of a chassis or its components must be done by qualified service per- sonnel only. Qualified service personne
Résumé du contenu de la page N° 10
OnSite Series Getting Started Guide Structure This guide contains the following chapters and appendices: • Chapter 1 describes the OnSite Series Metro-Optical Transport Access Nodes • Chapter 2 describes typical applications for the OS-10 series • Chapter 3 describes instructions for installing the OS-10 • Chapter 4 describes how to access the OS-10 for configuration and management • Chapter 5 contains information on contacting Patton technical support for assistance • Appendi
Résumé du contenu de la page N° 11
OnSite Series Getting Started Guide Typographical conventions used in this document This section describes the typographical conventions and terms used in this guide. General conventions The procedures described in this manual use the following text conventions: Table 1. General conventions Convention Meaning Indicates a cross-reference hyperlink that points to a figure, graphic, Garamond blue type table, or section heading. Clicking on the hyperlink jump
Résumé du contenu de la page N° 12
OnSite Series Getting Started Guide Safety when using electricity Read the installation instructions before connecting your OS-10 system to the power source. WARNING Follow these guidelines when working on equipment powered by electricity: • Locate the emergency power-off switch in the room in which you are working. Then, if an electrical acci- dent occurs, you can quickly turn off the power. • Never assume that power is disconnected from a circuit. Disconnect all power before install
Résumé du contenu de la page N° 13
OnSite Series Getting Started Guide Electrostatic Discharge Damage Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. It can occur if electronic printed circuit cards are improperly handled and can cause complete or intermittent failures. Always follow these ESD prevention procedures when removing and replacing expansion modules: • Ensure that the system chassis is electrically connected to earth ground. • Wear an ESD-preventive wrist strap, e
Résumé du contenu de la page N° 14
Chapter 1 Product Overview Chapter contents Introduction..........................................................................................................................................................15 OnSite Platforms ............................................................................................................................................15 14
Résumé du contenu de la page N° 15
OnSite Series Getting Started Guide 1 • Product Overview Introduction The OnSite Series is family of ultra-compact, micro multi-service provisioning platforms (µMSPPs). The sup- ports flexible and economic delivery of time division multiplexing (TDM) and Ethernet-based packet data ser- vices over synchronous digital hierarchy (SDH) transport networks. The OS-10 system has two STM-1 ports for connection to the SDH network. The ports operate at 155.520 Mbit/s and can be configured to ope
Résumé du contenu de la page N° 16
OnSite Series Getting Started Guide 1 • Product Overview Figure 2. OnSite Model 1063 Table 3. Base System Configuration for OnSite Platforms Type Model OS1052 Model OS1063 SDH Trunks 2 STM-1 2 STM-1 Client Signals 8 E1 or 8 T1 21 E1 or 21 T1 2 Ethernet – Management Serial RS-232 Serial RS-232 LAN LAN Expansion Slots 2 2 The OS1052 and OS1063 systems have two expansion slots. The expansion slots support the insertion of the following modules for flexible configuration changes and capacity up
Résumé du contenu de la page N° 17
OnSite Series Getting Started Guide 1 • Product Overview Figure 3. OS1052 Base System Figure 2 shows the front panel of the OS1063 system. The OS1063 uses a future bus connector for access to the 21 E1 or T1 ports on the base system. When the system is equipped with two 21-port high-density E1 (HD-E1) expansion modules, the OS1063 provides access for up to 63 E1 ports. (See chapter 12 for a descrip- tion of the future bus connector and the features of the high-density E1 expansion module.) As
Résumé du contenu de la page N° 18
Chapter 2 Application Overview Chapter contents OS1052 Application..............................................................................................................................................19 OS1063 Application..............................................................................................................................................21 18
Résumé du contenu de la page N° 19
OnSite Series Getting Started Guide 2 • Application Overview OS1052 Application The advanced modular design of the Patton OnSite OS1052 provides unequaled flexibility in its class in terms of service offerings, capacity and functional upgrades. Figure 5. Typical OS1052 application OS1052 Application 19
Résumé du contenu de la page N° 20
OnSite Series Getting Started Guide 2 • Application Overview The base OS1052 system is configured with: • 2 STM-1 • 8 E1/T1 • 2 Ethernet • 10/100Base-TX Two expansion module slots allow increasing system capacity beyond the initial base configuration. Additional ports and features only require simple insertion of one of the many available types of TDM and packet data modules. In only one RU, the OS1052 supports expansion up to: • 50 E1 ports • 18 Ethernet 10/100 ports The OS1052 incorporates n