Résumé du contenu de la page N° 1
BRIM-E6
USER’S GUIDE
CABLETRON SYSTEMS, P. O. Box 5005, Rochester, NH 03866-5005
Résumé du contenu de la page N° 2
NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice. IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (
Résumé du contenu de la page N° 3
NOTICE FCC NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable
Résumé du contenu de la page N° 4
NOTICE CABLETRON SYSTEMS, INC. PROGRAM LICENSE AGREEMENT IMPORTANT: Before utilizing this product, carefully read this License Agreement. This document is an agreement between you, the end user, and Cabletron Systems, Inc. (“Cabletron”) that sets forth your rights and obligations with respect to the Cabletron software program (the “Program”) contained in this package. The Program may be contained in firmware, chips or other media. BY UTILIZING THE ENCLOSED PRODUCT, YOU ARE AGREEING
Résumé du contenu de la page N° 5
NOTICE UENTIAL DAMAGES. IN NO EVENT SHALL 2. NO LIABILITY FOR CONSEQ CABLETRON OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS, PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR RELIANCE DAMAGES, OR OTHER LOSS) ARISING OUT OF THE USE OR INABILITY TO USE THIS CABLETRON PRODUCT, EVEN IF CABLETRON HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME STA
Résumé du contenu de la page N° 6
TABLE OF CONTENTS CHAPTER 1 INTRODUCTION 1.1 USING THIS MANUAL................................................................... 1 1.2 GETTING HELP ............................................................................. 2 1.3 BRIM-E6 OVERVIEW..................................................................... 2 1.4 BRIM-E6 FEATURES..................................................................... 2 1.5 BRIM-E6 SPECIFICATIONS.................................................
Résumé du contenu de la page N° 7
CONTENTS APPENDIX A EPIM SPECIFICATIONS A.1 EPIM-T (10BASE-T TWISTED PAIR PORT)................................25 A.2 EPIM-F1 AND EPIM-F2 (MULTIMODE FIBER OPTIC PORTS) ..26 A.3 EPIM-F3 (SINGLE MODE FIBER OPTIC PORT).........................27 A.4 EPIM-C (BNC PORT) ...................................................................29 A.5 EPIM-A AND EPIM-X (AUI PORTS).............................................30 APPENDIX B EPIM CABLE REQUIREMENTS B.1 CABLE REQUIREMENTS ................
Résumé du contenu de la page N° 8
CHAPTER 1 INTRODUCTION Welcome to the Cabletron Systems BRIM-E6 User’s Guide. This manual explains how to install the Bridge/Router Interface Module (BRIM) for Ethernet into Cabletron products that support BRIM technology (e.g., the EMM-E6 or MicroMMAC). It also explains BRIM-E6 features and specifications. 1.1 USING THIS MANUAL Read through this manual completely to familiarize yourself with its content and to gain an understanding of the features and capabilities o
Résumé du contenu de la page N° 9
CHAPTER 1: INTRODUCTION 1.2 GETTING HELP If you need additional support related to the BRIM-E6, or if you have any questions, comments, or suggestions concerning this manual, contact Cabletron Systems Technical Support: By phone ..........................(603) 332-9400 Monday-Friday; 8am - 8pm EST ® By CompuServe .............GO CTRON from any! prompt By Internet mail ...............support@ctron.com 1.3 BRIM-E6 OVERVIEW The BRIM-E6 extends the functionality of your individ
Résumé du contenu de la page N° 10
BRIM-E6 SPECIFICATIONS EPIM Connectivity EPIMs allow you to configure the BRIM-E6 to support a variety of media types. Cabletron Systems offers the EPIMs shown in Table 1-1. Table 1-1. EPIMs EPIM MEDIA TYPE CONNECTOR EPIM-A AUI DB15 (Female) EPIM-C 10BASE-2 Thin Coaxial BNC EPIM-T 10BASE-T Unshielded RJ45 Twisted Pair EPIM-X Standard Transceiver DB15 (Male) EPIM-F1 Multimode Fiber SMA EPIM-F2 Multimode Fiber ST EPIM-F3 Single Mode Fiber ST 1.5 BRIM-E6 SPECIFICATIONS The ope
Résumé du contenu de la page N° 11
CHAPTER 1: INTRODUCTION 1.6 ETHERNET BRIDGING Bridging Overview Ethernet bridges read in packets and make decisions to filter or forward based on the destination address of the packet. The simple filter/forward decision process allows a bridge to segment traffic between two networks, keeping local traffic local. This process increases the availability of each network while still allowing traffic destined for the opposite side of the bridge to pass. A bridge connects two networks together
Résumé du contenu de la page N° 12
ETHERNET BRIDGING As with repeaters, IEEE recommends a maximum number of bridges that can be in a signal path. With repeaters we are able to have a signal path of 4 repeaters, 5 segments. With bridges we can have a signal path of 7 bridges, 8 networks. The bridge count includes both local and remote bridges. Spanning Tree Algorithm Since bridges play a very important role in the transfer of data from one network to another, a helpful feature would be the ability to set up a redunda
Résumé du contenu de la page N° 13
CHAPTER 1: INTRODUCTION If Bridge 2 fails to receive the Bridge 1 BPDUs during the period defined by "Hello Time", Bridge 2 will initiate a re-span by transmitting a topology change BPDU and eventually come on line to carry the network load. Bridges using STA can be utilized to create very fault tolerant networks. This section has presented only basic information about bridges and Spanning Tree Algorithm. For additional information, refer to the IEEE 802.1d draft specifi
Résumé du contenu de la page N° 14
CHAPTER 2 INSTALLATION This chapter contains instructions for installing your BRIM-E6 into a Media Interface Module (MIM) or stand-alone product. It also explains how to install an EPIM into the BRIM-E6. Caution: Observe all static precautions while handling MIMs and EPIMs. 2.1 UNPACKING THE BRIM Unpack the BRIM as follows: 1) Remove the shipping box material covering the BRIM. 2) Carefully remove the module from the shipping box. Leave the module in its non-conductive bag until yo
Résumé du contenu de la page N° 15
CHAPTER 2: INSTALLATION 2.2.1 Installing a BRIM-E6 in a MIM To install a BRIM-E6 in a MIM that supports BRIM technology (e.g., EMM-E6 or ESXMIM): Note: We recommend that you power-down your hub even though Cabletron MIMs have “hot swap” capabilities. 1. Power-down your MMAC hub. 2. Disconnect all cables from the MIM. Note the ports to which these cables attach. 3. Unscrew the top and bottom knurled knobs of the MIM face plate. 4. Slide out the MIM, and place it on its side with the
Résumé du contenu de la page N° 16
INSTALLING BRIMs 6. Place your BRIM behind the MIM face plate. (See Figure 2-2.) Figure 2-2. Installing the BRIM 7. Insert the connector pins of the BRIM-E6 into the mother board connector on the MIM. 8. Press down firmly on the back of the BRIM until the pins slide all the way into the connector holes. Note: The BRIM-E6 connector must fit securely on the mother board connector. 9. Reinstall the faceplate mounting screws, and install the support post screws. Note: Faceplate and su
Résumé du contenu de la page N° 17
CHAPTER 2: INSTALLATION 2.2.2 Installing a BRIM in a Hub To install a BRIM-E6 into a stand-alone hub that supports BRIM technology (e.g., MicroMMAC or NBR-620): 1. Power-down your hub. 2. Disconnect all cables from the hub. Note the ports to which these cables attach. 3. Remove the hub chassis cover. Note: Refer to your specific hub documentation for instructions on removing the hub chassis cover. 4. Remove the BRIM coverplate screws and the BRIM coverplate. (See Figure 2-1.)
Résumé du contenu de la page N° 18
INSTALLING BRIMs 2.2.3 Installing an EPIM into the BRIM To install an EPIM into the BRIM: 1. Slide the EPIM into the BRIM slot. See Figure 2-3. BRIM-E6 STB XMT CLN RCV Figure 2-3. Installing an EPIM into the BRIM-E6 2. Press the EPIM connector firmly into the connector on the BRIM. 3. Tighten the EPIM screw. BRIM-E6 USER’S GUIDE Page 11
Résumé du contenu de la page N° 19
CHAPTER 3 CONNECTING TO THE NETWORK This chapter outlines the procedure for connecting the BRIM-E6 to a network. 3.1 CONNECTING THE BRIM TO THE NETWORK The procedure for connecting network segments to the BRIM-E6 depends on which EPIM you install. Refer to the following list and perform the procedure described in the subsections that apply to your configuration: • EPIM-T 3.1.1 • EPIM-F1, F2, F3 3.1.2 • EPIM-C 3.1.3 • EPIM-A 3.1.4 • EPIM-X 3.1.5 Prior to connecting the network cabling check the
Résumé du contenu de la page N° 20
CHAPTER 3: CONNECTING TO THE NETWORK Position X (crossed over) 1. RX+ 5. NC 2. RX- 6. TX- 3. TX+ 7. NC 4. NC 8. NC Position = (not crossed over) 1. TX+ 5. NC 2. TX- 6. RX- 3. RX+ 7. NC 4. NC 8. NC Figure 3-1. EPIM-T Cross-over Switch To connect an EPIM-T to a Twisted Pair Segment: 1. Insert the RJ45 connector on the twisted pair segment into the RJ45 port on the EPIM. See Figure 3-1. 2. Check that the EPIM’s LNK LED is on. If the LED is not on, perform each of the following steps until it is: