DNswitch 800 Web Management Guide Part Number: WM-DSA8G-00 March 2001 This book describes how to install, cable and use the Digital Networks DNswitch 800. Revision/Update Information: This is a new document.
Résumé du contenu de la page N° 4
Digital Networks makes no representations that the use of its products in the manner described in this publication will not infringe on existing or future patent rights, nor do the descriptions contained in this publication imply the granting of licenses to make, use, or sell equipment or software in accordance with the description. Possession, use, or copying of the software described in this publication is authorized only pursuant to a valid written license from Digital Networks or an auth
Résumé du contenu de la page N° 5
FCC Class B Certification (USA) This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Warning! This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable p
Résumé du contenu de la page N° 6
BSMI Class A (Taiwan) VCCI Class B Compliance (Japan) CE Mark Declaration of Conformance for EMI and Safety This is to certify that this product complies with ISO/IEC Guide 22 and EN45014. It conforms to the following specifications: EMC:EN55022(1988)/CISPR-22(1985) class B EN60555-2(1995) class B EN60555-3 IEC1000-4-2(1995) 4kV CD, 8kV AD IEC1000-4-3(1995) 3V/m IEC1000-4-4(1995) 1kV - (power line), 0.5kV - (signal line) IEC1000-4-6(1995) 3Vrms This product complies with the requirements of
Résumé du contenu de la page N° 7
Underwriters Laboratories Compliance Statement Important! Before making connections, make sure you have the correct cord set. Check it (read the label on the cable) against the following: Operating Voltage Cord Set Specifications 120 Volts UL Listed/CSA Certified Cord Set Minimum 18 AWG Type SVT or SJT three conductor cord Maximum length of 15 feet Parallel blade, grounding type attachment plug rated 15A, 125V 240 Volts (Europe only) Cord Set with H05VV-F cord having three 2 conductors with
Résumé du contenu de la page N° 8
c. Das Gerät war Feuchtigkeit ausgesetzt. d. Wenn das Gerät nicht der Bedienungsanleitung entsprechend funktioniert oder Sie mit Hilfe dieser Anleitung keine Verbesserung erzielen. e. Das Gerät ist gefallen und/oder das Gehäuse ist beschädigt. f. Wenn das Gerät deutliche Anzeichen eines Defektes aufweist. 15. Zum Netzanschluß dieses Gerätes ist eine geprüfte Leitung zu verwenden. Für einen Nennstrom bis 6A und einem Gerätegewicht größer 3kg ist eine Leitung nicht leichter 2 als H05VV-F, 3G, 0
Résumé du contenu de la page N° 9
Table of Contents 1. OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Digital Networks WebView Description. . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 System Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Résumé du contenu de la page N° 10
Priority . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Port Priority Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Port Traffic Class Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 VLAN Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Configuring Virtual LANs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 VLAN Basic In
Résumé du contenu de la page N° 11
1. OVERVIEW Digital Networks WebView Description This user guide describes Digital Networks WebView, a Web browser- based utility which allows you to remotely configure and manage Digital Networks products, including the DNswitch 800. There is no software to install as Web management capability is built into the switch’s management. Digital Networks WebView provides a graphical, real-time representation of the front panel on the DNswitch 800. This graphic, along with additionally defined ar
Résumé du contenu de la page N° 12
Conventions This guide uses the following user input conventions: When you read “Select,” use the mouse to either select the link identified by a hand icon, or select the identified button or area. When you read “Enter,” type in the text and select the button identified in the procedure. 2 Overview DNswitch 800
Résumé du contenu de la page N° 13
2. USING WEB-BASED MANAGEMENT Setting Up Web Management Before running Web-based management, some basic configuration of the switch may need to be performed. The following information at a minimum must be configured or known for the switch to be managed: IP Address Administrator password HTTP Server Enable In addition, several other parameters may need to be configured or known to properly communicate with the switch or allow full management capability. These include: Default Gateway
Résumé du contenu de la page N° 14
Setting a Default Gateway The default gateway parameter defines the IP address of a router or other network device to which IP packets are to be sent if destined for a subnet outside of that in which the switch is operating. This parameter must be set if you are attempting to manage the switch using Digital Networks WebView from a remote network or across the Internet. 1. Starting at the Main Menu of the console user interface, select Management Setup Menu / Network Configuration / IP Confi
Résumé du contenu de la page N° 15
Enabling Web Management The HTTP Configuration menu is used to enable or disable the ability to manage the switch with Web management. The HTTP Server parameter must be set to ENABLED before Digital Networks WebView can be used to manage the switch. If it is desired to disallow Web management of the switch, this parameter should be set to DISABLED 1. Starting at the Main Menu of the console user interface, select Management Setup Menu / Network Configuration / HTTP Configuration. 2. Selec
Résumé du contenu de la page N° 16
Digital Networks WebView User Interface The Digital Networks WebView user interface provides access to various switch configuration and management screens, allows you to view performance statistics, and permits you to graphically monitor system status. Areas of the User Interface Figure 2-1 shows the Digital Networks WebView user interface. The user interface is divided into four distinct areas as described in Table 2-1. Area 1 Area 3 Area 2 Figure 2-1. Digital Networks WebView User Interfa
Résumé du contenu de la page N° 17
Table 2-1. Areas of the User Interface Area Function 1 Presents a graphical near real-time image of the front panel of the selected switch. This area displays the switch’s ports, showing port activity, duplex mode, or flow control, depending on the specified mode. Various areas of the graphic can be selected for performing management functions, including the ports, management, or the case. 2 Displays a list of links allowing you to go to the associated menu or screen by selecting the item
Résumé du contenu de la page N° 18
Configuration Options Web pages that include selection options have a drop-down list with a “Select” button to confirm the selection. Configurable parameters have a dialog box or a drop-down list. Once a configuration change has been made on a page, be sure to click on the “Apply” button at the bottom of the page to confirm the new setting. The following table summarizes the Web page configuration buttons. Table 2-3. Web Page Configuration Buttons Button Action Select Sets the selected op
Résumé du contenu de la page N° 19
3. CONFIGURING AND MONITORING THE SWITCH This section, arranged by topic, describes how to perform common monitoring and configuration tasks on a DNswitch 800 using Digital Networks WebView. After you have properly configured the switch, and started Digital Networks WebView, you can perform any of the tasks described in the following sections. Screen Hierarchy The contents of this chapter are arranged following the structure shown in Figure 3-1. Figure 3-1. Digital Networks WebView Screen
Résumé du contenu de la page N° 20
System Information Use the System Information screen to display descriptive information about the switch, or for quick system identification as shown in the following figure and table. Figure 3-2. System Information Parameter Description 1 Name assigned to the switch system. System Name Object ID MIB II object identifier for switch’s network management subsystem. 2 IP address of the switch you are managing. The switch’s IP Address management supports SNMP over UDP/IP transport protocol. I