Total Access 600R User Interface Guide (UIG) Trademarks Any brand names and product names included in this manual are trademarks, registered trademarks, or trade names of their respective holders. To the Holder of the Manual The contents of this manual are current as of the date of publication. ADTRAN reserves the right to change the contents without prior notice. In no event will ADTRAN be liable for any special, incidental, or consequential damages or for commercial losses even if ADTRAN ha
Résumé du contenu de la page N° 3
Total Access 600R User Interface Guide (UIG) Notes provide additional useful information. Caution signify information that could prevent service interruption. Warnings provide information that could prevent damage to the equipment or endangerment to human life. Safety Instructions When using your telephone equipment, please follow these basic safety precautions to reduce the risk of fire, electrical shock, or personal injury: 1. Do not use this product near water, such as a bathtub, wash bowl,
Résumé du contenu de la page N° 4
Total Access 600R User Interface Guide (UIG) FCC regulations require that the following information be provided in this manual to the customer: 1. This equipment complies with Part 68 of the FCC rules. On the side of the bot- tom of this equipment is a label that contains, among other information, the FCC Registration Number and Ringer Equivalence Number (REN), if applica- ble, for this equipment. If required, this information must be given to the tele- phone company. 2. An FCC-compliant telep
Résumé du contenu de la page N° 5
Total Access 600R User Interface Guide (UIG) Federal Communications Commission (FCC) Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance wi
Résumé du contenu de la page N° 6
Total Access 600R User Interface Guide (UIG) Industry Canada Compliance Information Notice: The Industry Canada label applied to the product (identified by the Industry Canada logo or the “IC:” in front of the certification/registration number) signifies that the Industry Canada technical specifications were met. Notice: The Ringer Equivalence Number (REN) for this terminal equipment is supplied in the documentation or on the product labeling/markings. The REN assigned to each terminal device
Résumé du contenu de la page N° 7
Total Access 600R User Interface Guide (UIG) Affidavit Requirements for Connection to Digital Services • An affidavit is required to be given to the telephone company whenever digital terminal equipment without encoded analog content and billing protection is used to transmit digital signals containing encoded analog content which are intended for eventual conversion into voiceband analog signals and transmitted on the network. • The affidavit shall affirm that either no encoded analog conte
Résumé du contenu de la page N° 8
Total Access 600R User Interface Guide (UIG) Affidavit for Connection of Customer Premises Equipment to 1.544 Mbps and/or Subrate Digital Services For the work to be performed in the certified territory of ___________________(telco name) State of ________________ County of ________________ I, _______________________ (name), _____________________________(business address), ____________________ (telephone number) being duly sworn, state: I have responsibility for the operation and maintenance o
Résumé du contenu de la page N° 9
Total Access 600R User Interface Guide (UIG) I agree to provide ______________________ (telco’s name) with proper documentation to demonstrate compliance with the information as provided in the preceding paragraph, if so requested. _________________________________Signature _________________________________Title _________________________________ Date Transcribed and sworn to before me This ________ day of _______________, 20____ _________________________________ Notary Public My commission ex
Résumé du contenu de la page N° 10
Total Access 600R User Interface Guide (UIG) Warranty and Customer Service ADTRAN will repair and return this product within ten years from the date of shipment if it does not meet its published specifications or fails while in service. For detailed warranty, repair, and return information refer to the ADTRAN Equipment Warranty and Repair and Return Policy Procedure. Return Material Authorization (RMA) is required prior to returning equipment to ADTRAN. For service, RMA requests, or further in
Résumé du contenu de la page N° 11
Total Access 600R User Interface Guide (UIG) Customer Service, Product Support Information, and Training ADTRAN will repair and return this product if within ten years from the date of shipment the product does not meet its published specification or the product fails while in service. A return material authorization (RMA) is required prior to returning equipment to ADTRAN. For service, RMA requests, training, or more information, use the contact information given below. Repair and Return If
Résumé du contenu de la page N° 12
Total Access 600R User Interface Guide (UIG) Post-Sale Support Your reseller should serve as the first point of contact for support. If additional support is needed, the ADTRAN Support web site provides a variety of support services such as a searchable knowledge base, updated firmware releases, latest product documentation, service request ticket generation and trouble- shooting tools. All of this, and more, is available at: http://support.adtran.com When needed, further post-sales assistance
Résumé du contenu de la page N° 13
Total Access 600R User Interface Guide (UIG) TOTAL ACCESS 600R USER INTERFACE GUIDE This User Interface Guide is designed for use by network administrators and others who will configure and provision the system. It contains information about navigating the VT 100 user interface, configuration information, and menu descriptions. TABLE OF CONTENTS Navigating the Terminal Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Terminal Men
Résumé du contenu de la page N° 14
Total Access 600R User Interface Guide (UIG) Initial Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Setting up Bridging Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 FIGURES Figure 1. Top-Level Terminal Menu Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Figure 2. Alternate Menu View . . . .
Résumé du contenu de la page N° 15
Total Access 600R User Interface Guide (UIG) 1. NAVIGATING THE TERMINAL MENU Terminal Menu Window The Total Access 600R uses a multi-level menu structure that contains both menu items and data fields. All menu items and data fields display in the terminal menu window (see Figure 1), through which you have complete control of the Total Access 600R. Menu Path Left Pane Right Pane Network Status ^A=more Extended Help Navigation Help Tool Tip System Time Figure 1. Top-Level Terminal Menu Window M
Résumé du contenu de la page N° 16
Total Access 600R User Interface Guide (UIG) Window Panes When you first start a terminal menu session, the terminal menu window is divided into left and right panes. The left pane shows the list of available submenus, while the right pane shows the contents of the currently selected submenu. You can view the terminal windows in two ways: with fields and submenus displaying horizontally across the right pane, or with fields and submenus displaying vertically down the right pane. Viewing submen
Résumé du contenu de la page N° 17
Total Access 600R User Interface Guide (UIG) Window Pane Navigation Use the following chart to assist you in moving between and within the two window panes. To do this... Press this key... Move from left pane to right pane Tab Enter Right arrow Move from right pane to left pane Tab Escape Left arrow Backspace Move within each pane Up arrow Down arrow Left arrow Right arrow Right Window Pane Notation The right window pane shows the contents of the currently selected menu. These contents can inclu
Résumé du contenu de la page N° 18
Total Access 600R User Interface Guide (UIG) Moving through the Menus To do this... Press this key... Return to the home screen H Jump between two menu items J Press while the cursor is located on a menu item, and you jump back to the main screen. Go to another menu item, press , and you jump back to the screen that was displayed the first time you pressed . Press anytime you want to jump between these items. Select items Arrows Edit a selected menu item Enter Cancel an edit Escap
Résumé du contenu de la page N° 19
Total Access 600R User Interface Guide (UIG) Configuration Keystrokes To do this... Press this key... Restore factory default settings. F This setting restores the factory defaults based on the location of the cursor. If the cursor is on a module line (in the MODULES menu), then only the selected module is updated to fac- tory defaults. Copy selected items to the clipboard. C The amount of information you can copy depends on the cursor location when you press : If the cursor is over an edit
Résumé du contenu de la page N° 20
Total Access 600R User Interface Guide (UIG) 2. TERMINAL MENU AND SYSTEM CONTROL Selecting the Appropriate Menu The terminal menu is the access point to all other operations. Each terminal menu item has several functions and sub- menus that identify and provide access to specific operations and parameters. Use the chart below to help select the appropriate terminal menu. To do this... Go to this menu... Review and monitor general system information for the Total Access 600R SYSTEM INFO Set up t