Résumé du contenu de la page N° 1
User’s Guide
S4TEF10xx-11x
Stand-Alone Media Converter
• Twisted-Pair Copper to Fiber
10/100Base-TX to 100Base-FX
RS-232 to Fiber
(4) T1/E1 to Fiber
The S4TEF10xx-11x media converter is
designed to extend signals from a 10Base-T
Ethernet/100Base-TX Fast Ethernet port, an
RS-232 data port, and up to four (4) T1/E1
network ports over fiber. The Ethernet, RS-232, and T1/E1 interfaces are independent of
each other and the signals from these ports can be sent over the fiber interface
simultaneously.
Résumé du contenu de la page N° 2
4 S4TEF10xx-11x Part Number Fiber-Optic - Single Fiber, Single Mode, 100Base-FX Installation -- Continued SC, 1310 mn TX/1550 nm RX, 20 km (12.4 miles)* S4TEF1029-110 Configuration switches SC, 1550 mn TX/1310 nm RX, 20 km (12.4 miles)* S4TEF1029-111 The S4TEF10xx-11x media converter has two (2) sets of configuration switches. Note: S4TEF1029-110 and S4TEF1029-111 are intended to be installed in the same • Set #1 (upper) sets the T1/E1 options. link where one is the local converter and the ot
Résumé du contenu de la page N° 3
S4TEF10xx-11x Installation -- Continued Installation -- Continued Switch set #1 - T1/E1 options Switch set #2 - serial and ethernet options 5, 6, 7, 8 - Loop-Back settings 1, 2, 3 - Serial connection speed line settings The loop-back setting is used for installation and network debugging procedures. Each Switches 1, 2, and 3 on switch set #2 are used to set the serial connection speed. of the T1/E1 ports can be individually set for loop-back mode: 1 2 3 1 2 3 • Switch 5 controls T1/E1 port 1 •
Résumé du contenu de la page N° 4
S4TEF10xx-11x Installation — Continued Installation -- Continued Switch set #2 - serial and ethernet options Switch set #2 - serial and ethernet options 6 - Twisted-pair Auto-Negotiation 9 - Transparent Link Pass-Through 9 6 up Up (Enabled) - The media converter “advertises” up Up - Enable Link Pass-Through ALL rate and mode capabilities to the network: Down - Disable Link Pass-Through Enable Link Pass-Through • 100 Mb/s full- or half-duplex Enable Auto-Negotiation • 10 Mb/s full- or half-dup
Résumé du contenu de la page N° 5
S4TEF10xx-11x Installation — Continued Installation -- Continued Hardware/software jumper Install the fiber cable The jumper is located on the circuit board, inside the media 1. Locate or build ITU-compliant fiber cable with male, two-stranded TX to RX converter housing. connectors installed at both ends. Software Mode Hardware: 2. Connect the fiber cables to the local S4TEF10xx-11x media converter as described: The media converter mode is determined by the switch • Connect the male TX cable
Résumé du contenu de la page N° 6
4 S4TEF10xx-11x Installation -- Continued Operation -- Continued Install the RS-232 data cable (included) Ethernet LEDs 1. Use the enclosed RS-232 data cable with a male, DIN 6-pin connector on one Use the bi-color status LEDs (embedded in the 10/100Base-TX RJ-45 connector) to end and a DB-9 connector installed on the other end. monitor the Ethernet connections. 2. Connect the DIN 6-pin connector to the RS-232 port on the S4TEF10xx-11x Duplex/Link LED: media converter. Amber = A link on the hal
Résumé du contenu de la page N° 7
S4TEF10xx-11x Operation -- Continued Operation — Continued Accessing the local RS232 factory maintenance interface Remote management function 1. Make sure that this Device is configured for accessing the maintenance The S4TEF10xx-11x can be remotely managed when connected via fiber cable to a interface via the RS232 port (Switch #10, on Bank #1, down. See page 4). local C4TEF10xx-11x slide-in-module media converter that is installed in a managed Transition Networks PointSystem™ chassis. The SNM
Résumé du contenu de la page N° 8
SBFTF10xx-10x Operation -- Continued Operation -- Continued To show the configuration menu for the local device: Setting the password: 1. At the prompt, type the letter “C,” press the spacebar, then type the letter “L.” 1. At the prompt, press the letter “P” key. 2. Press the ENTER key and the local device configuration menu will appear as 2. At the prompt, type any alphanumeric combination (8 characters maximum) shown below: 3. Press the ENTER key: the password is set. Note: In this menu, the
Résumé du contenu de la page N° 9
S4TEF10xx-11x Operation -- Continued Operation -- continued To show the configuration menu for the remote device: To update the PIC code of a remote device: 1. At the prompt, type the letter “C,” press the spacebar, then type the letter “R.” 1. At the prompt, type the letter “U.” 2. Press the ENTER key and the remote device configuration menu will appear: 2. Press the ENTER key and the code will start to transfer. On the screen, the incrementing percent line shows the percent of the transferrin
Résumé du contenu de la page N° 10
S4TEF10xx-11x Operation -- continued Cable Specifications To Reset the local device: The physical characteristics must meet or exceed ITU and IEEE802.3 specifications. Caution: This command will interrupt T1/E1 and Ethernet traffic. It will take Fiber cable several seconds to restore the data path. Failure to observe this caution might cause Bit Error Rate: <10-9 data loss. Single mode fiber (recommended): 9 μm 1. At the prompt, type the letter “R.” Multimode fiber (recommended): 62.5/125 μ
Résumé du contenu de la page N° 11
S4TEF10xx-11x T1/E1 cable Cable Specifications -- Continued Category 3: (minimum requirement) The fiber optic transmitters on this device meet Class 1 Laser safety requirements per Connector: RJ-48C IEC-825/CDRH standards and complies with 21 CFR1040.10 and 21 CFR1040.11. Electrical network connection: Single 4-wire (Tip/Ring - Tip1/Ring1) Ethernet cable Mechanical arrangement: 8-position miniature modular jack Usage: 1.544 Mb/s access lines Category 3: (minimum requirement for 10 Mb/s operati
Résumé du contenu de la page N° 12
S4TEF10xx-11x Cable Specifications —Continued Technical Specifications RS-232 cable (included with the media converter) For use with Transition Networks Model S4TEF10xx-11x or equivalent. Standards IEEE 802.3™, G.703, AMI/B8Z3/HDB3 Connectors Gauge: 6-pin DIN and DB-9 / 24-22 AWG Attenuation: 20 dB/1000 ft. @ 10 MHz Data Rate Copper: 10 Mb/s, 100 Mb/s; Fiber: 100 Mb/s Differential characteristic impedance: 100 ohm +/- 10% @ 10 MHz Dimensions 3.7" x 4.7" x 1.8" (93 x 120 x 47 mm) Maximum cable d
Résumé du contenu de la page N° 13
S4TEF10xx-11x Troubleshooting -- Continued Troubleshooting If the media converter fails, isolate and correct the failure by determining the answers 5. Is the “LNK” LED on a T1/E1 port (with a copper cable installed) illuminated? to the following questions and then taking the indicated action: NO • Check the copper cable connected to that T1/E1 port for proper connection. 1. Is the “PWR” LED illuminated? • Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600. NO YES • Ensure that the p
Résumé du contenu de la page N° 14
S4TEF10xx-11x Compliance Information Contact Us CE Mark Technical support Technical support is available 24 hours a day. FCC regulations US and Canada: 1-800-260-1312 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection International: 00-1-952-941-7600 against harmful interference when the equipment is operated in a commercial environment. This equipment ge
Résumé du contenu de la page N° 15
S4TEF10xx-11x Compliance -- continued VCCI Class 1 compliance This equipment is in the 1st Class category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set by the Voluntary Control Council For Interference by Data Processing Equipment and Electronic Office Machines aimed at preventing radio interference in commercial and/or industrial areas. When used in a residential area or in an adjacent area thereto, interference may be caused to radio