Résumé du contenu de la page N° 1
AC Adapter
AW-PS300
Before attempting to connect or operate this product,
please read these instructions completely.
Résumé du contenu de la page N° 2
For U.S.A CAUTION Warning: RISK OF ELECTRIC SHOCK Do not install this product near any object that burns easily. DO NOT OPEN In case of using a halogen lamp, installation of it near such an object could cause a fire due to the heat generated by the lamp. CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SER- For CANADA VICEABLE PARTS INSIDE. This digital apparatus does not exceed the Class A limits for REFER SERVICING TO QUALIFIED SERVICE PER- radio noise emis
Résumé du contenu de la page N° 3
CONTENTS FEATURES ................................................................................................................................................................................... 1 PRECAUTIONS ............................................................................................................................................................................. 2 MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS ...................................................................
Résumé du contenu de la page N° 4
PRECAUTIONS • Handle the adaptor with care. • Care Dropping the control panel or subjecting it to a strong Pull out the power cable plug, and wipe the control shock can cause a failure or an accident. panel clean with a dry cloth. If it is extremely dirty, dip a cloth into a diluted solution of kitchen detergent, • Operating temperature range –10°C to +45°C squeeze it hard, and wipe the product surfaces care- Avoid using it in a cold place below –10°C or a hot fully. place above +45°C because lo
Résumé du contenu de la page N° 5
FUSE FUSE n MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS FRONT PANEL FUSE(POWER) FUSE(LAMP) POWER OFF O I ON FUSE FUSE T T AC Adaptor 125V 3.15A 125V 6.3A POWER AW-PS300 q Power Switch (POWER, ON/OFF) e Fuse [FUSE (POWER)] Power is switched on to supply power to the pan/tilt Power fuse. Use a 125V, 3.15A fuse to replace it. head when this switch is pressed to the ON position (POWER Indicator lights), and is switched off when the r Lamp Fuse [FUSE (LAMP)] switch is pressed to the OFF positio
Résumé du contenu de la page N° 6
- n FRONT PANEL LAMP AC OUT AC IN OPTION SW OPTION SW LAMP DC 15V CONTROL OUT CONTROL IN CONTROL OUT OP C S + 100V 500W t AC 120V Inlet [AC IN](AC 3P Inlet) y to short or open, using a cable (to be locally pur- 2 Connect the supplied AC cable. chased) with a nominal cross section of 0.3 mm or more that meets the UL specifications. The maximum y Option Switch Terminal (OPTION SW CONTROL allowable cable length is 30 meters. OUT) (2P Terminal Board) Applicable Wire A relay switch capable of co
Résumé du contenu de la page N° 7
i Lamp Control Input Terminals (LAMP CONTROL Applicable (usable) wire C/S) (2P Terminal Board) Solid wire: ø1.29 (AWG 16) 2 Connect it to LAMP CONTROL C/S Terminals on the Stranded wire: 1.25 mm (AWG 16) pan/tilt head when controlling the halogen lamp con- Strand diameter ø0.18 or more nected to LAMP AC OUT Connector !0 to switch it on Standard bare end length 11 mm and off, using a cable (to be locally purchased) with a 2 nominal cross section of 0.3 mm or more that meets !0 Lamp AC Output Conn
Résumé du contenu de la page N° 8
CONNECTION • Switch off all the devices before making any connec- Applicable wire tion. Solid wire: ø1.29 (AWG 16) • Use the Pan/tilt Head AW-PH300. 2 Stranded wire: 1.25 mm(AWG16) • Connect the DC 15V OUT Terminals [+] and [–] on this Usable wire range adapter to the DC 15V IN Terminals [+] and [–] on the Solid wire: ø0.64 to 1.29 (AWG 22 to 16) Pan/tilt Head (AW-PH300) respectively with cables (to 2 2 Stranded wire: 0.3 mm to 1.25 mm be locally purchased) with a nominal cross section of 2 (AWG
Résumé du contenu de la page N° 9
- • For a detailed description of con- necting the individual devices, refer to their Operating Instructions. • Connect the supplied AC cable to the AC 120V inlet. Plug the AC cable to an AC outlet, and press the power switch on the adapter Pan/tilt Head to the ON position. AW-PH300 Lamp Control Cable Halogen Lamp 2 (Nominal cross section 0.3 mm or more, to be locally purchased) * Unnecessary if lamp control is not needed. DC cable 2 (Nominal cross section 1.25 mm or Option switch control cable
Résumé du contenu de la page N° 10
SPECIFICATIONS Source Voltage: 120 V AC 60 Hz Input Capacity: 552W Power Output: DC 15V OUT: DC15V 2.5A, with over-current protect circuit LAMP AC OUT: 120V AC, max. 500W, min. 250W Pan/tilt head connecting cables: 5 cables (2 DC power cables, 2 lamp control cables, 1 option switch control cable) (in case of using the lamp control and option switch control functions) Maximum cable length 30 m Operating temperature: –10°C to +45°C (14°F to 113°F) Dimensions: 210(W) x 51(H) x 250(D) mm 8-1/4”(W) x
Résumé du contenu de la page N° 11
Broadcast & Television Systems Company Division of Matsushita Electric Corporation of America Executive Office: One Panasonic Way 2E-6, Secaucus, NJ 07094 Regional Offices: EASTERN ZONE: 43 Hartz Way, Secaucus, NJ 07094 (201) 348-7620 CENTRAL ZONE: 1707 North Randall Road, Elgin, IL 60123 (847) 468-5200 SOUTHERN ZONE: Atlanta Region: 1225 Northbrook Parkway, Suite 1-160, Suwanee, GA 30174 Panazip 11 (770) 338-6841, fax (770) 338-6741 Law Enforcement Video Products: 1225 Northbrook Parkway, Suite