Résumé du contenu de la page N° 1
NPort 5600 Series User’s Manual
Seventh Edition, July 2006
www.moxa.com/product
MOXA Technologies Co., Ltd.
Tel: +886-2-8919-1230
Fax: +886-2-8919-1231
Web: www.moxa.com
MOXA Technical Support
Worldwide: support@moxa.com
Résumé du contenu de la page N° 2
NPort 5600 Series User’s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement. Copyright Notice Copyright © 2006 MOXA Technologies Co., Ltd. All rights reserved. Reproduction without permission is prohibited. Trademarks MOXA is a registered trademark of The MOXA Group. All other trademarks or registered marks in this manual belong to their respective manufacturers. Disclaime
Résumé du contenu de la page N° 3
Table of Contents Chapter 1 Introduction..............................................................................................1-1 Overview............................................................................................................................ 1-2 Package Checklist .............................................................................................................. 1-2 Product Features........................................................................
Résumé du contenu de la page N° 4
UDP Mode ............................................................................................................ 5-23 Pair Connection Mode .......................................................................................... 5-25 Reverse Telnet Mode ............................................................................................ 5-27 Disabled Mode...................................................................................................... 5-28 RFC2217 Mode.....
Résumé du contenu de la page N° 5
Appendix C SNMP Agent with MIB II & RS-232 Like Group .................................... C-1 Appendix D Auto IP Report Protocol......................................................................... D-1 Appendix E Service Information................................................................................ E-1 MOXA Internet Services....................................................................................................E-2 Problem Report Form.............................
Résumé du contenu de la page N° 6
1 1 Chapter 1 Introduction The MOXA NPort 5600 Series of advanced serial device servers make it easy to network-enable your serial devices. The NPort 5600 Series includes 8 models: NPort 5610-16, NPort 5610-8 (8 or 16 RS-232 ports, with AC power), NPort 5610-16-48V, NPort 5610-8-48V (8 or 16 RS-232 ports, with DC power), NPort 5630-16, NPort 5630-8 (8 or 16 RS-422/485 ports, with AC power), and NPort 5650-16, NPort 5650-8 (8 or 16 RS-232/422/285 ports, with AC power). In this manual, we
Résumé du contenu de la page N° 7
NPort 5600 Series User’s Manual Getting Started Overview The NPort 5600 Series serial device servers are designed to make your industrial serial devices Internet ready instantly. The compact size of the NPort 5600 device servers makes them the ideal choice for connecting your RS-232 (NPort 5610-16/8), RS-422/485 (NPort 5630-16/8), or RS-232/422/485 (NPort 5650-16/8) serial devices—such as PLCs, meters, and sensors—to an IP-based Ethernet LAN, making it possible for your software to access
Résumé du contenu de la page N° 8
NPort 5600 Series User’s Manual Getting Started Product Specifications LAN Ethernet 10/100 Mbps, RJ45 Protection Built-in 1.5 KV magnetic isolation Optical Fiber Distance Multi mode: 0 to 2 km, 1310 nm (62.5/125 µm, 500 MHz*km) Single mode: 0 to 40 km, 1310 nm (9/125 µm, 3.5 PS/(nm*km)) Min. TX Output Multi mode: -20 dBm Single mode: 0 to 40 km, -5 dBm Max. TX Output Multi mode: -14 dBm Single mode: 0 to 40 km, 0 dBm Sensitivity -36 to -32 dBm (Single), -34 to -30 dBm (Multi) NP
Résumé du contenu de la page N° 9
NPort 5600 Series User’s Manual Getting Started Advanced Built-in Features HMI LCM display with four push buttons Buzzer Real-Time Clock Watch Dog Timer Serial Communication Parameters Parity None, Even, Odd, Space, Mark Data Bits 5, 6, 7, 8 Stop Bit 1, 1.5, 2 Flow Control RTS/CTS, XON/XOFF, DSR/DTR (Excluded NPort 5630) Transmission Speed 50 bps to 921.6 Kbps Software Features Protocols ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP, HTTP, SMTP, SNTP, Rtelnet, ARP, PP
Résumé du contenu de la page N° 10
2 2 Chapter 2 Getting Started This chapter includes information about installing NPort 5600 Series. The following topics are covered: Panel Layout Connecting the Hardware Wiring Requirements Connecting NPort 5610/30/50-16/8’s Power Connecting NPort 5610-16/8-48V’s Power Grounding NPort 5610-16/8-48V Connecting to the Network Connecting to a Serial Device LED Indicators Link Indicator on the Rear Panel of NPort 5650 Fiber Model Real Time Clock Adjustable Termination
Résumé du contenu de la page N° 11
NPort 5600 Series User’s Manual Initial IP Address Configuration Panel Layout The following figures depict the front and rear panels of the NPort 5600 series. Front panel of NPort 5600 series 5610-16 Rear panel of NPort 5600 series (AC Power) Serial ports 12345678 9 10111213141516 LAN AC POWER 100-240V, 47-63Hz Rear panel of NPort 5600 series (DC Power) Serial ports 12345678 9 10111213141516 LAN V+ V- Rear panel of NPort 5650 Fiber model Fiber Serial ports 12345678 9 101112131
Résumé du contenu de la page N° 12
NPort 5600 Series User’s Manual Initial IP Address Configuration Connecting the Hardware This section describes how to connect NPort 5600 Series to serial devices for first time testing purposes. We cover Wiring Requirements, Connecting NPort 5610/30/50-16/8’s Power, Connecting NPort 5610-16/8-48V’s Power, Grounding NPort 5610-16/8-48V, Connecting to the Network, Connecting to a Serial Device, and LED Indicators. Wiring Requirements ATTENTION Safety First! Be sure to disconnect the pow
Résumé du contenu de la page N° 13
NPort 5600 Series User’s Manual Initial IP Address Configuration 1. Loosen the screws on the V and V terminals of NPort 5610-16/8-48V’s + - terminal block. 2. Connect the power cord’s 48 VDC wire to the terminal block’s V + terminal, and the power cord’s DC Power Ground wire to the terminal V+ V- block’s V terminal, and then tighten the terminal block screws. (Note: - NPort 5610-16/8-48V can still operate even if the DC 48V and DC Power Ground are reversed.) If the power is properly s
Résumé du contenu de la page N° 14
NPort 5600 Series User’s Manual Initial IP Address Configuration Connecting to a Serial Device Connect the serial data cable between NPort 5600 and the serial device. LED Indicators The front panels of NPort 5600 have several LED indicators, as described in the following table. LED Name LED Color LED Function off Power is off, or power error condition exists. Steady on: Power is on and NPort is booting up. red Blinking: Indicates an IP conflict, or DHCP or BOOTP server did not respond
Résumé du contenu de la page N° 15
NPort 5600 Series User’s Manual Initial IP Address Configuration To set a termination resistor to 150 K Ω, make sure both of the assigned DIP switches are in the OFF position. This is the default setting. To set a termination resistor to 1 K Ω, make sure both of the assigned DIP switches are in the ON position. ATTENTION Do not use the 1 K Ω setting on the NPort 5650 when using the RS-232 interface. Doing so will degrade the RS-232 signals and shorten the maximum allowed communication
Résumé du contenu de la page N° 16
3 3 Chapter 3 Initial IP Address Configuration When setting up your NPort 5600 for the first time, the first thing you should do is configure the IP address. This chapter introduces several methods to configure NPort’s IP address. Select the method that is the most convenient for you. For more details about network settings, see the Network Settings section from Chapter 5, Web Console Configuration. This chapter includes the following sections: Initializing NPort’s IP Address Factor
Résumé du contenu de la page N° 17
NPort 5600 Series User’s Manual Choosing the Proper Operation Mode Initializing NPort’s IP Address 1. Determine whether your NPort needs to use a Static IP or Dynamic IP (either DHCP or BOOTP application). 2. If NPort is used in a Static IP environment, you can use NPort Administration Suite, ARP, Web Console, or Telnet Console to configure the new IP address. 3. If NPort is used in a Dynamic IP environment, you can use NPort Administration suite, Web Console, or Telnet Console to configu
Résumé du contenu de la page N° 18
NPort 5600 Series User’s Manual Choosing the Proper Operation Mode There are four push buttons on NPort’s nameplate. Going from left to right, the buttons are: Button Name Action MENU menu activates the main menu, or returns to an upper level scrolls up through a list of items shown on the LCM panel’s second line up cursor scrolls down through a list of items shown on the LCM panel’s second down cursor line SEL select selects the option listed on the LCM panel’s second line The but
Résumé du contenu de la page N° 19
NPort 5600 Series User’s Manual Choosing the Proper Operation Mode Level 1 Level 2 Level 3 Main Menu Server Serial number D setting Server name C Firmware ver D Model name D Network Ethernet status D setting MAC address D IP config C IP address C Netmask C Gateway C DNS server 1 C DNS server 2 C Serial set Select port C Baudrate C Data bit C Stop bit C Parity C Flow control C Tx/Rx fifo C Interface C Tx/Rx bytes D Line status D Op Mode set Select port C Select m
Résumé du contenu de la page N° 20
NPort 5600 Series User’s Manual Choosing the Proper Operation Mode Parity attribute under Serial set as an example. Follow the tree graph to arrive at the following Parity screen. The first option, None, is displayed, with a down arrow all the way to the right. This is an indication that there are other options from which to choose. P a r i t Y N O n e ↓ Press the down cursor button once to see Odd as the second option. P a r i t Y O D D ↓