Precision Cooling
™
For Business-Critical Continuity
™
Liebert Mini-Mate2 1 To 8 Tons
Overhead Precision Cooling And Humidity Control
Résumé du contenu de la page N° 2
The Solution For Your Cooling Needs May Be Right Above You When the need calls for precision cooling and humidity Liebert Mini-Mate2 Offers: control, but your floor space says otherwise, the Liebert Reliability: ™ Mini-Mate2 can provide the overhead answer. This High Sensible Cooling Capacity. Unlike “comfort” air conditioners, Liebert systems are designed for the flexible, space-saving system is the ideal solution for cooling requirements of electronic equipment – 80% of small areas where sp
Résumé du contenu de la page N° 3
Liebert Monitoring Solutions: When You Need To Know You will find a full-range of monitoring and control systems, communications modules designed to interface Liebert equipment with Low Total Cost Of Ownership: a variety of building management systems, plus stand-alone monitoring, High-Efficiency Compressor. The rotary or scroll control and leak detection devices. compressors are both energy-efficient and rugged, to ensure continuous operation. Local And Remote Advanced Monitoring ® Monit
Résumé du contenu de la page N° 4
The Right Size To Fit Your Space And Application With more than 10,000 possible configurations, there is a LiebertMini-Mate2 system available to fit the needs of many room cooling or spot cooling requirements. Liebert Mini-Mate2™ Product A Variety Of Options Help You Meet Features Include: Numerous Applications: Available in 1,1.5, 2, 3, 5 & 8 ton capacities Grille (1-1.5 tons) or Plenum (2-3 tons) that fits 2’x4’ (3-stage cooling on 8-ton) ceiling grid for direct supply & return air distrib
Résumé du contenu de la page N° 5
5-Ton Ducted Liebert Mini-Mate2 Capacity (Tons) Product Option Availability 1 1.5 2 3 5 8 Chilled Water (rated @ 300 psi static pressure) • • • Chilled Water (rated @ 400 psi static pressure) •• Self-Contained Air-Cooled • • Self-Contained Water/Glycol-Cooled • • Split System Air-Cooled w/Centrifugal Indoor Condensing Unit • • • • Split System Air-Cooled w/Outdoor High Ambient Prop Fan Condensing Unit • • • Split System Air-Cooled w/Outdoor Prop Fan Condensing Unit • • • • • • Split System Ai
Résumé du contenu de la page N° 6
1 1 And 1- /2 Ton Systems Air-Cooled Water/Glycol Chilled-Water Expansion Tank Drycooler Pump Self-Contained Air-Cooled with Grille Self-Contained Glycol System with Grille Chilled-Water with Grille Expansion Tank Drycooler Pump Self-Contained Glycol System Ducted Chilled-Water Ducted Self-Contained Air-Cooled Ducted Optional Filter Box, Duct Connection Available Optional Filter Box, Duct Connection Available Optional Filter Box, Duct Connection Available Cooling Tower Prop Fan
Condensing
Evap
Résumé du contenu de la page N° 7
Specifications 1 1 And 1- /2 Ton Systems 60 HZ 50 HZ AIR COOLED SYSTEM with Outdoor Condensing Unit with Centrifugal Condensing Unit with Outdoor Condensing Unit with Centrifugal Condensing Unit Split System Self-Contained Split System Self-Contained 1 Ton 1.5 Tons 1 Ton 1.5 Tons 1 Ton 1.5 Tons 1 Ton 1.5 Tons Evaporator MMD12E MMD18E MMD12A MMD18A MMD11E MMD17E MMD11A MMD17A Condensing Unit PFH014A PFH020A MM2CF MM2CF PFH013A PFH019A MM2CF MM2CF Net Capacity Data*BTUH (kW) High Fan
Résumé du contenu de la page N° 8
2 And 3 Ton Systems Air-Cooled Water/Glycol Chilled-Water Utilizes Split System Evaporator Utilizes Split System Evaporator Centrifugal Fan
E Expansion Tank Condensing Unit Water/Glycol
Condensing Unit Evaporator Evaporator E Drycooler Pump Remote Air-Cooled Condensing Unit Remote Water/Glycol-Condensing Unit Chilled-Water Supply & Return Air Plenum Supply & Return Air Plenum Supply & Return Plenum Centrifugal Fan
Condensing Unit Expansion Tank Evaporator C Water/Glycol
Condensing Unit E
Résumé du contenu de la page N° 9
Specifications 2 And 3 Ton Split Systems 60 HZ 50 HZ AIR COOLED SYSTEM with Outdoor Condensing Unit with Centrifugal Condensing Unit with Outdoor Condensing Unit with Centrifugal Condensing Unit 2 Tons 3 Tons 2 Tons 3 Tons 2 Tons 3 Tons 2 Tons 3 Tons Evaporator MMD24E MMD36E MMD24E MMD36E MMD23E MMD35E MMD23E MMD35E Condensing Unit PFH027A PFH037A MCD24A MCD36A PFH026A PFH036A MCD23A MCD35A Net Capacity Data*BTUH (kW) High Fan Speed 80 F (26.7 C) DB Total 25,600 (7.5) 36,900 (10.8)
Résumé du contenu de la page N° 10
5 And 8 Ton Systems Air-Cooled Water/Glycol Chilled-Water Utilizes Split System Evaporator Utilizes Split System Evaporator Cooling Tower Evaporator Evaporator Evaporator Centrifugal Fan
Water/Glycol- Condensing Unit Condensing Unit Indoor Air-Cooled Condensing Unit Remote Water/Glycol-Condensing Unit Chilled-Water Coil Supply & Return Air Ducted Supply & Return Air Ducted Supply & Return Air Ducted Optional Filter Box/Duct Connection Available Optional Filter Box/Duct Connection Available Op
Résumé du contenu de la page N° 11
Specifications 5 And 8 Ton Split Systems 60 Hz 50 Hz AIR COOLED SYSTEM w/Outdoor Condensing Unit w/Centrifugal Condensing Unit w/Outdoor Condensing Unit w/Centrifugal Condensing Unit 5 Tons 5 Tons 5 Tons 5 Tons Evaporator MMD60E MMD60E MMD59E MMD59E Condensing Unit PFH067A MCD65A PFH066A MCD64A Net Capacity Data*-BTUH (kW) 80 F (26.7 C) DB Total 65,000 (19.0) 66,200 (19.4) 65,400 (19.2) 65,500 (19.2) 50% RH Sensible 54,400 (15.9) 54,800 (16.1) 54,800 (16.1) 54,800 (16.1) 75 F (23.9 C) DB To
Résumé du contenu de la page N° 12
Ensuring The High Availability Of Mission-Critical Data And Applications. Liebert Corporation Emerson Network Power, the global leader in enabling business-critical continuity, 1050 Dearborn Drive ensures network resiliency and adaptability through a family of technologies — P.O. Box 29186 Columbus, Ohio 43229 including Liebert power and cooling technologies — that protect and support 800 877 9222 Phone (U.S. & Canada Only) business-critical systems. Liebert solutions employ an adaptive arch