Résumé du contenu de la page N° 1
® ™
Hotwire ReachDSL Modem, Model 6350-A4
with Inline Phone Filter
Installation Instructions
Document Number 6350-A2-GN12-00
September 2001
Contents
Hotwire 6350 ReachDSL Modem Overview ................................................. 1
Getting Started .............................................................................................. 4
Installing the Hotwire 6350 ReachDSL Modem ............................................ 5
Power-On .................................................
Résumé du contenu de la page N° 2
Hotwire ReachDSL System Copper pairs run from the central office (CO) to the customer premises (CP) to create the local loop. The local loop terminates on the customer premises at the demarcation point. Customer Premises (CP) Central Office ReachDSL (CO) Modem DSL/POTS Local Loop End-user Ethernet Network Ethernet Systems Crossover or Service Cable Cable Provider Demarcation (NSP) Point Hub 00-16867 DSL – Digital Subscriber Lines POTS – Plain Old Telephone Service NOTES: In this document: —
Résumé du contenu de la page N° 3
POWER ETHERNET PHONE LINE Phone Filter Depending on the type of phone handset and the quality of the home or business wiring, a phone filter is recommended to minimize background noise during a phone conversation. An internal phone filter is included with the Hotwire 6350 ReachDSL Modem. If additional telephones are used on the same phone line as the ReachDSL modem, install one phone filter on each telephone. There are two Hotwire phone filters: Hotwire 6035 Universal Phone Filter is desi
Résumé du contenu de la page N° 4
Getting Started Before beginning your modem’s installation, make sure that you have all the equipment that you need. Package Checklist Verify that your package contains the following: ❑ Hotwire 6350 ReachDSL Modem ❑ DSL interface cable with RJ11 connectors ❑ Power cord with power transformer Be sure to register your warranty at www.paradyne.com/warranty. Wiring and Cables You Need The following standard cables and connectors are used with this product: ❑ Standard RJ11 (or RJ14) wall jack for th
Résumé du contenu de la page N° 5
PHONE LINE POWER ETHERNET Installing the Hotwire 6350 ReachDSL Modem Place the Hotwire 6350 ReachDSL Modem on a flat surface with clearance for the rear connectors. Procedure 1. If a telephone is connected at the RJ11 RJ11 wall jack where the modem will be installed, Wall Jack unplug the telephone line from the wall jack. 2. Connect a telephone to the modem. (Optional – go to Step 3 if you are not connecting a telephone to the ReachDSL modem.) Plug the existing telephone interface cabl
Résumé du contenu de la page N° 6
POWER ETHERNET PHONE LINE PHONE LINE POWER ETHERNET 4. Use an 8-pin Ethernet cable for the Ethernet connection. Insert one end of the cable into the jack labeled ETHERNET. — Use a straight-through cable and connect the other end to an Ethernet hub. (To connect to a hub’s Uplink connection, use an Ethernet crossover cable). Ethernet Line Ethernet Hub Ethernet Straight-Through Cable 01-17008 –or– — Use an Ethernet crossover cable and connect the other end to a PC with an Ethernet Network Int
Résumé du contenu de la page N° 7
PHONE LINE POWER ETHERNET 5. Insert the supplied power cord’s round end into the jack labeled POWER. Plug the transformer into an AC outlet. Power Jack Transformer or 01-17010 The ReachDSL modem hardware installation is now complete. When the power cord is installed, the ReachDSL modem goes through a power-on self-test. Power-On When power is applied, the ReachDSL modem performs self-diagnostics and the PWR LED is on. The self-diagnostics includes a power-on self-test and all of the LEDs tu
Résumé du contenu de la page N° 8
Status LEDs All of the LEDs turn on and off during the power-on self-test. After a successful self-test, the LEDs should appear as indicated in BOLD in the Condition column below. LED Condition Status PWR ON ReachDSL modem has power. ALM OFF No active alarms. ON An alarm condition exists. TST OFF No active tests. ON The TST LED is on during the power-on self-test and during a test initiated by the service provider. LINE ON The DSL link is active and ready to transmit and receive data. OFF
Résumé du contenu de la page N° 9
Troubleshooting LED Symptom Action All LEDs are on. If LEDs remain on after ten minutes, the modem is not functional. Contact the service provider. ALM LED remains The power-on self-test may have failed. Unplug the unit and on. reapply power. If the alarm LED is still on, contact the service provider. ALM and TST LEDs Firmware download may be in progress. If firmware download is are blinking. not in progress or the LEDs continue blinking after ten minutes, contact the service provider. Ethe
Résumé du contenu de la page N° 10
To improve data transmission throughput and minimize background noise during a telephone conversation, make sure that: The Hotwire 6350 ReachDSL Modem is always powered on, even when not in use, and A Hotwire phone filter is installed on every telephone on the same line as the Hotwire 6350 ReachDSL Modem (see Phone Filter on page 3). Increasing the Number of End-User Systems A single end-user system is attached to the Hotwire 6350 ReachDSL Modem by using an Ethernet crossover cable. To i
Résumé du contenu de la page N° 11
Cables & Connectors This section is reference information. Standard twisted-pair CAT3 or better cables are recommended. The LINE and PHONE interface connectors 6-Pin use 6-pin, non-keyed modular plugs. RJ11 or RJ11 Plugs RJ14 6-pin connectors can be used. Line & Phone Connectors Pin # Function 1 Not used 2 Ring 2 (optional) Pin #6 3 DSL Ring 1 Pin #1 4DSL Tip 1 5 Tip 2 (optional) 98-15304a 6 Not used The LINE and PHONE jack pinouts are either filtered or unfiltered for POTS. PHONE Jack Pi
Résumé du contenu de la page N° 12
The Ethernet interface connector uses an 8-pin, non-keyed modular plug. — To connect the DSL modem to an Ethernet hub, use the straight-through Ethernet Cable connection. 8-Pin Straight-through Connection Pin # Function 8-Pin 1 10BaseT TX D+ Plug 2 10BaseT TX D– 3 10BaseT RX D+ 4 & 5 Not used Pin #8 6 10BaseT RX D– Pin #1 98-16055a 7 & 8 Not used –or– — To connect the DSL modem directly to a PC with an Ethernet NIC card, use an Ethernet crossover cable. 8-Pin Ethernet Crossover Cable Functi
Résumé du contenu de la page N° 13
Optional ReachDSL Modem Wall Placement The Hotwire 6350 ReachDSL Modem is designed for tabletop placement. The modem can also be mounted on a wall. To mount the modem, you will need: ❑ Two slotted-head #6 self-threading screws with plastic anchors ❑ Drill and 3/16" drill bit for the plastic anchors ❑ Screwdriver A template with the dimensions for the two screws is provided. See ReachDSL Modem Hardware Template on page 14. Procedure To mount the Hotwire 6350 ReachDSL Modem: 1. Use a drill to
Résumé du contenu de la page N° 14
ReachDSL Modem Hardware Template 01-17014 14 Top 5.10 Bottom
Résumé du contenu de la page N° 15
Technical Specifications for Hotwire 6350 ReachDSL Modem Item Specification* Height x Width x Depth 1.46" x 5.72" x 4.33" (3.71 cm x 14.54 cm x 11.00 cm) 0.45 lb. (0.20 kg) Weight Power Class 2 Transformer normal Input: 100 VAC (+10%), 50 Hz; service input voltage range 120 VAC (+10%), 60 Hz; or 230 VAC (+10%), 50/60 Hz Output: 5 VDC nominal, minimum 0.6A (SELV) Approvals FCC Part 15 Class B digital device CISPR 22 Class B Other Certifications Refer to equipment’s label for approvals on produ
Résumé du contenu de la page N° 16
! Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered. 3. Do not allow anything to rest on the power cord and do not locate the product where persons will walk on the power cord. 4. Do not attempt to service th
Résumé du contenu de la page N° 17
CE Marking When the product is marked with the CE mark on the equipment label, this demonstrates full compliance with the following European Directives: Directive 73/23/EEC – Council Directive of 19 February 1973 on the harmonization of the laws of the member states relating to electrical equipment designed for use within states relating to electrical equipment designed for use within certain voltage limits, as amended by Directive 93/68/EEC. Directive 89/336/EEC – Council Directive of 3
Résumé du contenu de la page N° 18
Declaration of Conformity This Declaration of Conformity is made by Paradyne Corporation pursuant to Parts 2 and 15 of the Federal Communications Commission’s Rules. This compliance information statement pertains to the following products: Trade Name: Hotwire Model Number: 6350-A4-200 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference re
Résumé du contenu de la page N° 19
Supplier’s Declaration of Conformity Place of Issue: Paradyne Corporation th 8545 126 Avenue North Largo, FL 33773-1502 USA Date of Issue: 8/17/2001 ® Paradyne Corporation, located at the above address, hereby certifies that the Hotwire ReachDSL™ Model Number 6350-A4-200, bearing labeling identification number US:AW2DL03B6350-A4 complies with: the Federal Communications Commission’s (“FCC”) Rules and Regulations 47 CFR Part 68, the Administrative Council on Terminal Attachments (“ACTA”)-adop
Résumé du contenu de la page N° 20
Government Requirements Certain governments require that instructions pertaining to connection to the telephone network be included in the installation and operation manual. Specific instructions are listed in the following sections. United States – Notice to Users of the Telephone Network 1. This equipment complies with Part 68 of the FCC rules. On the equipment is a label that contains, among other information, the FCC approval number which includes the Ringer Equivalence Number (REN) for