Résumé du contenu de la page N° 1
I
N
S
T
R
H600 MIXER
U
C
T
I
O
N
S
H600 & L800 MIXERS
MODELS
H600 ML - 104241, 104242, 104383, 104384
L800 ML - 104244, 104245, 104425, 104429
701 S. RIDGE AVENUE
TROY, OHIO 45374-0001
FORM 18812 Rev. B (12-99)
Résumé du contenu de la page N° 2
Model H600 Mixer Model L800 Mixer © HOBART CORPORATION, 1994 – 2 –
Résumé du contenu de la page N° 3
123456789012345678901234567890121234567890 1 2345678901234567890123456789012123456789 0 1 2345678901234567890123456789012123456789 0 Installation, Operation, and Care of 1 2345678901234567890123456789012123456789 0 1 2345678901234567890123456789012123456789 0 1 2345678901234567890123456789012123456789 0 1 2345678901234567890123456789012123456789 0 H600 and L800 MIXERS 1 2345678901234567890123456789012123456789 0 1 2345678901234567890123456789012123456789 0 1 2345678901234567890123456789012123456
Résumé du contenu de la page N° 4
INSTALLATION UNPACKING Immediately after unpacking the mixer, check for possible shipping damage. If this machine is found to be damaged after unpacking, save the packaging material and contact the carrier within 15 days of delivery. Prior to installation, test the electrical service to assure that it agrees with the specifications on the machine data plate. LOCATION Place the mixer in its operating location. There should be adequate space around the mixer for the user to operate the controls
Résumé du contenu de la page N° 5
ELECTRICAL CONNECTIONS WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTION OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES. WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT. ELECTRICAL DATA Rated Circuit Size Fuse Size * 60°C Copper Circuit Size Circuit Breaker ** 60°C Copper Model Volts / Hz / Ph Amps (Amps) (Amps) Wire Size (Amps) (Amps) Wire Size H600 115
Résumé du contenu de la page N° 6
OPERATION WARNING: MOVING BEATER IN BOWL, KEEP HANDS, CLOTHING, AND UTENSILS OUT WHILE IN OPERATION, DO NOT USE WITHOUT INTERLOCKED GUARD. Every H600 and L800 mixer is equipped with either an Electro-Mechanical Timer Control (described at the bottom of this page) or a Programmable Timer Controller (described on pages 7 – 9). Also, become familiar with the other operating parts (Fig. 2) and their functions, which are referenced throughout the OPERATION section (pages 6 – 12). The Bowl Guard mus
Résumé du contenu de la page N° 7
PROGRAMMABLE TIMER CONTROLLER (when equipped) At Idle, the timer display [ – – : – – ] shows that no time has been set (Fig. 4). TIME DISPLAY TIMER CONTROL P1 KNOB KEY P1 P2 12 3 4 KEY TIME SAVE P2 SAVE KEY M/C CLEAR INDICATOR CLEAR KEY M / C START BUTTON START STOP BUTTON STOP PL-51307 Fig. 4 Timer Keys Programming Function (if the mixer is not mixing). P1 Contains up to four preset times. Displays each preset time sequentially. P2 Contains up to four additional preset times. Displ
Résumé du contenu de la page N° 8
PROGRAMMABLE TIMER CONTROLLER (when equipped) continued Using the Preset Keys, P1 or P2, to set the Mixing Time . . . Each preset key has four time settings. The indicator above the number 1, 2, 3, or 4 and the P1 or P2 indicator light identify which preset time is being displayed. The chart below shows the default settings; the next page shows how to revise these preset times. The Dial Timer KNOB can be used to adjust the mixing time if the knob is turned prior to pressing START. Beginning f
Résumé du contenu de la page N° 9
PROGRAMMABLE TIMER CONTROLLER (when equipped) continued To Revise the Preset Mixing Times contained in P1 or P2 . . . Each preset key has four preset time settings. The indicator above the number 1, 2, 3, or 4 and the P1 or P2 indicator light identify which preset time is being displayed. Beginning from the Idle display [ – – : – – ], press P1 or P2 to display the #1 preset - mixing time. ( Pressing P1 or P2 again will display the next preset time, etc.) P1 01:00 - - - - - P2 Turn the KNOB t
Résumé du contenu de la page N° 10
CHANGING SPEEDS The GEAR SHIFT LEVER is used to change speeds. Always stop the mixer before changing speeds. To change speeds, push the STOP button, move the gear shift lever to the desired speed, and restart the mixer by pushing the START button. NOTE: If you do not stop the mixer to change speeds, it will automatically shut itself off and you will have to restart it after changing speeds. STANDARD BOWL LIFT The Handwheel is used to raise and lower the bowl on mixers with the standard bowl li
Résumé du contenu de la page N° 11
Bowl Guard (Fig. 5) The Wire Cage Assembly on the Bowl Guard can be rotated out-of-the-way to add ingredients or access the bowl and agitator. To rotate the Wire Cage Assembly to the rear . . . Push the Latch in to release the Centering Pin from the Centering Ramp. Note how the grooves on the nylon Retainers allow the Wire Cage to ride around the circular Ridge of the planetary Drip Cup. The Wire Cage can rotate 360°; left or right. When the Wire Cage returns to the front and center position,
Résumé du contenu de la page N° 12
Attachments To install an attachment, loosen the attachment hub thumb screw and remove the plug. Insert the attachment into the attachment hub, making certain that the square shank of the attachment is in the square driver of the mixer. Secure the attachment by tightening the thumb screw. Move the gear shift lever to the desired speed. With the bowl support all the way up and the wire cage in the front-center position, start the mixer to operate the attachment. The meat and food chopper attac
Résumé du contenu de la page N° 13
MAINTENANCE WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT BEFORE BEGINNING ANY MAINTENANCE PROCEDURE. LUBRICATION Planetary The planetary oil should be checked periodically. To check, DISCONNECT ELECTRICAL POWER SUPPLY and remove the Drip Cup-Splash Guard, which is secured by three screws. Remove the fill plug (Fig. 6). Oil should be even with the bottom of the fill plug hole. If it is not, slowly add the
Résumé du contenu de la page N° 14
Transmission The transmission oil should be even with the line on the Oil Level Gauge when the motor is NOT running. If the oil falls below this line, DISCONNECT ELECTRICAL POWER SUPPLY and remove the Top Cover, which is secured by two screws. Remove the Transmission Fill Plug (Fig. 7) and add a small amount of the recommended transmission oil until it returns to the proper level. DO NOT overfill the transmission as leakage may result. Contact your local Hobart Service Office for the recommen
Résumé du contenu de la page N° 15
ADJUSTMENTS Agitator Clearance The agitator clearance should be checked with each bowl change. The agitator must not touch the bowl 1 and the maximum clearance between the bottom of the bowl and the B Flat Beater is ⁄8"; the maximum 5 clearance between the bottom of the bowl and the E or ED Dough Arm is ⁄16". Install a Bowl and Agitator. If the Bowl and Beater come into contact before the Bowl Support reaches its stop, adjust the Stop Screw upwards following the procedure below. To Measure the
Résumé du contenu de la page N° 16
TROUBLESHOOTING SYMPTOMS POSSIBLE CAUSES Mixer will not start. 1. Gear shift lever between gears (not fully engaged). 2. Circuit protector in open position — check fuse or disconnect switch. 3. Mixer or attachment overloaded. 4. Bowl not all the way up. 5. Wire Cage Assembly is not in the front-center position. Agitator touches bowl. 1. Bowl clamp(s) not closed. 2. Improper agitator clearance — see MAINTENANCE for adjustment procedure. 3. Bowl clamp(s) improperly adjusted — see MAINTENANCE for a