Résumé du contenu de la page N° 1
Operation Manual
LRB 3000PRO
LASER RANGE FINDER BINOCULAR
In USA: 2331 Superior Ave. Cleveland, OH 44114
In Canada: 105 Sparks Ave., Toronto, ON M2H 2S5
Newcon International ltd. © 2005-2006 Printed in Canada
Résumé du contenu de la page N° 2
10. QUALITY CERTIFICATE IMPORTANT INFORMATION Read prior to activation The LRB 3000PRO has passed the quality inspection. You have just purchased a complicated electronic device, which emits invisible laser radiation. To operate it properly, please Production date ____________________________ read this manual carefully. Here are some common precautions that must be noted. Serial number _____________________________ • NEVER direct laser radiation at the eyes of p
Résumé du contenu de la page N° 3
9. CUSTOMER SUPPORT Features of the LRB 3000PRO Laser Range Finder Binocular Should you experience any difficulties with your Newcon Optik • Latest digital circuitry allows targeting through most types product, please consult the enclosed manual. If the problem of glass remains unresolved, contact our customer support department at • First, last or the most reflective target acquisition +1-416-663-6963 or toll free in North America at • Meters/Yards/Degrees/KMH/MPH display 1-87
Résumé du contenu de la page N° 4
TABLE OF CONTENTS 8. WARRANTY 1. Brief description NEWCON OPTIK warrants this product against defects in 2. Appearance of the device material and workmanship for one year from the date of the 3. Supplied accessories original date of consumer's purchase, but no more than 18 4. Technical characteristics months from the date of manufacturing. If your Newcon product 5. Operation instructions proves to be defective during this period, please bring the 5.1. Preparing the device fo
Résumé du contenu de la page N° 5
7. TROUBLESHOOTING CAREFULLY READ ALL THE INSTRUCTIONS BEFORE The range-measuring mode does not work. The display is USING! transparent. Check whether the battery is installed properly. Check the charge FAILURE TO OBEY THE INSTRUCTIONS WILL VOID of the battery. Replace it if it is weak THE WARRANTY! The range-measuring mode temporarily does not work. The display indicates results of the last measurement or transparent. Wait for 8 seconds, and press the Action button again.
Résumé du contenu de la page N° 6
2. APPEARANCE OF THE DEVICE 6. STORAGE AND MAINTENANCE INSTRUCTIONS. Precautions: LRB 3000Pro is a sophisticated precision optical instrument equipped with electronics. Therefore, it should be 4 3 1 handled with due care. 6 • Keep your device away from direct sunlight, impacts, dust, 5 moisture, and sudden changes of temperatures. o • Do not use the device at temperatures higher than 50 C o (122 F). • Do not touch the optical surfaces with fingers. Doing so may damage the anti
Résumé du contenu de la page N° 7
voltage of the primary 9-Volt battery drops below 7.2 Volts. At 1 this point the System is still functional but the battery should be replaced as soon as possible. The System can operate at the voltage level above 7 Volt. The System remains in the active displaying state for 8 seconds after pressing of any of the operating buttons and after 8 seconds it enters the passive zero power state. Ni-MH rechargeable type 7 of batteries with extended capacity capable to sustain current 8 drain
Résumé du contenu de la page N° 8
4. TECHNICAL CHARACTERISTICS Distance measuring procedure includes instant statistical processing of the package of single measuring sessions for each 1. Optics Magnification, x 7 laser pulse. Qualitative result of the statistical processing is Objective lens diameter, mm 40 presented on the Display as a message TARGET Exit pupil diameter, mm 5.7 REFLECTION (5). Field of view 6 ° There are three statistical qualifications of the reflected signal: Type of coating Fully multi-coated
Résumé du contenu de la page N° 9
5.4. Additional display information 5. OPERATION INSTRUCTIONS Liquid Crystal Display (LCD) The System operates in the setting Modes that are displayed as follows (refer to Fig.3): 7 Y/M – units of distance measurement: yards or meters (3). 6 KMH/MPH – units of speed measurement: km/hour or 1 miles/hour (3). 8 ° - units of angular measurement: degrees (3) 9 Shape of the reticle: cross shape or rectangular shape (2). 5 rEC1 - recall function. Upon pressing the Action button (4)
Résumé du contenu de la page N° 10
• rEc – recall function. Upon pressing the Action button (6) 5.1. Preparing the device for operation. (fig. 1) the Display will sequentially show results of last 10 • Rotate counterclockwise and open the battery compartment measurements, starting from the latest one. The number cover (5) located between the objective lenses (fig. 1). appearing after word "rEc" shows the number of the • Insert one 9V Ni-MH battery into the battery compartment measurement counted back in the sequence. Wh
Résumé du contenu de la page N° 11
• Cd12 – this mode sets the target selection to First. No If you choose more than one parameter to measure (for instance, distance and azimuth), the measured results will appear other parameters of those, which were previously set, are influenced. on the display every half second. • Cd13 – this mode sets the target selection to Auto. No If the A button is held (pressed) the System automatically other parameters of those, which were previously set, are enters SCANNING mode. At this mode, the
Résumé du contenu de la page N° 12
behind bushes, wires, flakes, or, opposite, measure a distance to • Cd4, Cd5, Cd6, Cd7 – reserved for the future extension wire, which hangs in front of the building wall. However, it and are not available in this model. cannot be guaranteed that the device will always measure the • Cd8 – the unit will measure two parameters at once as needed distance. It can happen that there will be no pulses distance in yards and horizontal angles in degrees. bounced off the desired object at all. Targe
Résumé du contenu de la page N° 13
If you want to leave the mode switching procedure without There is one default preset mode, Standard1 (Meters, Degrees, Crosshair shape reticle, Auto target selection), which opens the remembering your choice, you should press and keep held the M button for more than two seconds. This works like “Escape” key mode trek. on a computer keyboard. The rangefinder will remain in the last Another standard mode is assigned to Code 8. It determines set mode and return to the READY state. measuremen
Résumé du contenu de la page N° 14
A Last C o de 11 M M od e Screen displ ay Targe t S elect this m od e Go to n ext mo de A First C o de 12 M A S elect this mod e Targe t Auto Go to n ext mo de M 1) S t a nda r d 1 , , , Meter Degree Target S elect this mod e A Auto Go to n ext mod e C o de 13 M M A Targe t 2) Codes S elect this m od e Go to n ext mo de Go in to su bmenu Go to n ext mod e A C o de 14 M A Meter KMH C ode 1 M Meter S elect this m od e Go to n ext mod e S elect this mo de