Résumé du contenu de la page N° 1
®
IMPULSE
Non-Carbonated Post-Mix Beverage Dispenser
Installation & Operation Manual
Release Date: December 16, 2003
Publication Number: 859000159INS
Revision Date: NA
Revision: A
www.cornelius.com
Résumé du contenu de la page N° 2
Impulse Installation and Operation Manual CONTACT INFORMATION This an abbreviated manual. Keep this manual in case there are questions about operating the unit. The products, technical information, and instructions contained in this manual are subject to change with- out notice. These instructions are not intended to cover all details or variations of the equipment, nor to provide for every possible contingency in the installation, operation or maintenance of this equipment. This manual assu
Résumé du contenu de la page N° 3
Impulse Installation and Operation Manual TABLE OF CONTENTS SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Recognize safety alerts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Authorized Service Personnel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 CO2 (Carbon Dioxide) Warning . . . . . . . . . . . . . . . . . . . .
Résumé du contenu de la page N° 4
Impulse Installation and Operation Manual Publication Number: 859000159INS - ii - © 2003, IMI Cornelius Inc.
Résumé du contenu de la page N° 5
Non-Carbonated Impulse Installation & Operations Manual SAFETY RECOGNIZE SAFETY ALERTS This is the safety alert symbol. When you see it in this manual or on the AUTHORIZED SERVICE PERSONNEL CAUTION — Only trained and certified electrical, plumbing and refrigeration techni- cians should service this unit. ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL CODES. CO (CARBON DIOXIDE) WARNING 2 WARNING — CO Displaces Oxygen. Strict Attention must be observed in the pre- 2 vention of CO gas
Résumé du contenu de la page N° 6
Non-Carbonated Impulse Installation & Operations Manual INSTALLATION CAUTION — Only trained and certified electrical, plumbing and refrigeration techni- cians should service this unit. ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL CODES. NOTE: Water pipe connections and fixtures directly connected to the potable water supply must be sized, installed, and maintained in accordance with NSF Standard 18, as well as Federal, State, and Local codes. NOTE: It is the installer’s resp
Résumé du contenu de la page N° 7
Non-Carbonated Impulse Installation & Operations Manual INSTALLATION PROCEDURE Counter-top Installation NOTE: Optional 4-inch legs (p/n 3184) will elevate the unit 4 inches above counter (order 4 legs). 1. Place the unit on a level counter capable of supporting at least 400 pounds. 2. Remove drip tray and front access panel. 3. Turn power switch off then remove screw located next to the power switch and the screw at top of front panel. Next, remove front panel, disconnect wires to valve key
Résumé du contenu de la page N° 8
Non-Carbonated Impulse Installation & Operations Manual NOTE: Make sure that the electrical power circuit breaker is switched off or the fuse removed. Before connecting electrical power to the unit, refer to nameplate to verify the power require- ments. A. Remove the following: • front merchandiser by removing two screws on the top and lifting up • key switch wires • hood by removing two screws on the top and lifting up and forward. B. Remove second valve from the left to facilitate routi
Résumé du contenu de la page N° 9
Non-Carbonated Impulse Installation & Operations Manual Adjusting Flow Rates Flow rates of the water and concentrate are adjusted based on the desired ratio. For example: if the desired ratio is 5:1, then the flow rate of the water is 5 times that of the concentrate. If the desired finished drink flow rate is 3.0 ounces per second, then the water flow rate is 2.5 oz./sec. and the concentrate flow rate is 0.5 oz./sec. (The water at 2.5 oz./sec. is five times the 0.5 oz./sec. con- centrate flow
Résumé du contenu de la page N° 10
Non-Carbonated Impulse Installation & Operations Manual OPERATIONS OPERATIONS Starting And Stopping the Unit ON/OFF switch Key-lock switch 1. Push power ON/OFF switch to ON to power on the unit. 2. Insert key into key lock and turn to the ON to activate valves. Dispensing Product To dispense beverage press a cup or glass against the lever or push the button on the valve cover. Replenishing Concentrate Supply Bag-In-Box System: 1. Disconnect the concentrate tube from the empty bag-in-box and remo
Résumé du contenu de la page N° 11
Non-Carbonated Impulse Installation & Operations Manual CLEANING & CHECKS Daily Cleaning 1. Remove nozzle assembly and rinse with warm (not hot) water. If possible, soak nozzle assembly over night in carbonated water then rinse with warm water. Diffuser Nozzle 2. Wash external surfaces with mild soap solution, rinse with clean water, and wipe dry. Remove the drip tray, wash with mild soap solution, rinse and dry. NOTE: Do not use abrasive or harsh cleaners on the unit. Daily Checks 1. Check C
Résumé du contenu de la page N° 12
Non-Carbonated Impulse Installation & Operations Manual 2. Connect potable water source to the remaining concentrate systems and flush detergent solution out of the concentrate systems as instructed in step 9 preceding. 3. Remove potable water source from the concentrate system. STEP 3. Sanitize Concentrate Systems o o 1. Using five-gallon container (bag-in-box system), prepare sanitizing solution using 70 F (21 C) o o to100 F (38 C) potable water and 0.5 oz. (15 ml) of non-scented household l
Résumé du contenu de la page N° 13
Non-Carbonated Impulse Installation & Operations Manual REFERENCE MATERIAL WIRING DIAGRAM © 2003, IMI Cornelius Inc. - 9 - Publication Number: 859000159INS
Résumé du contenu de la page N° 14
Non-Carbonated Impulse Installation & Operations Manual PLUMBING DIAGRAMS Internal Carbonator COOLING COILS CARBONA TED WA T E R MANIFOLD NON-CARBONA TED DRINK 1 2 PLAIN WA T E R CO2 CHECK 3 VALVE 4 5 REMOTE CARBONA TOR REGULA TED CO2 SUPPLY 6 DISPENSER DISPENSING VALVE (6) SYRUP SUPPLY (SYRUP TANKS OR BAG-IN-BOX SYSTEM) LINE LEGEND CO2 PLAIN WATER SYRUP CARB WATER External Carbonator Publication Number: 859000159INS - 10 - © 2003, IMI Cornelius Inc.
Résumé du contenu de la page N° 15
Non-Carbonated Impulse Installation & Operations Manual © 2003, IMI Cornelius Inc. - 11 - Publication Number: 859000159INS
Résumé du contenu de la page N° 16
Non-Carbonated Impulse Installation & Operations Manual TROUBLESHOOTING Trouble Probable Cause Remedy Troubleshooting Dispensing System WATER-TO-CONCENTRATE • Dispensing valve concentrate • Adjust Water-to-Concentrate “RATIO”TOO LOW OR TOO flow regulator not properly “Ratio” as instructed. HIGH. adjusted. • CO2 gas pressure to concen- • Adjust concentrate pumps CO2 trate pumps insufficient to oper- regulator as instructed. ate pumps. ADJUSTMENT OF DISPENSING • No concentrate supply. • Replenis
Résumé du contenu de la page N° 17
Non-Carbonated Impulse Installation & Operations Manual Troubleshooting Refrigeration System COMPRESSOR DOES NOT • Ice bank sufficient. • Refrigeration not called for. OPERATE. • Unit power cord unplugged or • Plug in power cord or place control board power switch in switch in “ON” position. “OFF” position. • No power source (blown fuse or • Replace fuse or reset circuit tripped circuit breaker). breaker (note: Fuse or circuit breaker are not part of unit). • Low voltage at compressor ter- •
Résumé du contenu de la page N° 18
Non-Carbonated Impulse Installation & Operations Manual • No power source. Blown fuse • Replace fuse or reset circuit or. tripped circuit breaker breaker (note: Fuse or circuit breaker are not part of unit). • Agitator motor propeller • Remove obstruction. obstructed. • Low voltage at compressor ter- • Voltage must be at least 103 minals. volts at the compressor termi- nals when compressor is trying to start. • Loose, disconnected, or bro- • Tighten connections or replace ken wiring. broken
Résumé du contenu de la page N° 19
blank
Résumé du contenu de la page N° 20
IMI Cornelius Inc. One Cornelius Place Anoka, MN 55303-1592 U.S.A.