Résumé du contenu de la page N° 1
STUDER INNOTEC COMPACT
User and installer Manual
Sine wave Inverter, Battery charger, Transfersystem
COMPACT C 1600-12
COMPACT C 2600-24
COMPACT C 4000-48
Temperature sensor CT-35
Remote control RCC-01
Solar charge controller Cxxxx-S
Remote power sharing RPS-01
AC cable cover CFC-01
IP-23 top cover C-IP23
STUDER INNOTEC TEL: ++41 (0)27 205 60 80
Rue des Casernes 57 FAX: ++41 (0)27 205 60 88
CH-1950 SION in
Résumé du contenu de la page N° 2
STUDER INNOTEC COMPACT Summary 1 GENERAL INFORMATION...............................................................................................................4 1.1 OPERATING INSTRUCTIONS........................................................................................................................4 1.2 QUALITY AND WARRANTY...................................................................................................
Résumé du contenu de la page N° 3
STUDER INNOTEC COMPACT 4.7.3 DELAYED MODE OF THE TRANSFER SYSTEM.....................................................................................17 4.8 THE SOLAR CHARGE CONTROLLER (OPTION) ............................................................................................17 4.9 THE MULTIFUNCTIONAL CONTACT............................................................................................................18 4.10
Résumé du contenu de la page N° 4
STUDER INNOTEC COMPACT 1 General Information 1.1 Operating instructions This manual is a part of the delivery package of every COMPACT inverter-charger. It serves as guidelines for safe and efficient operation of COMPACT. The instructions are only valid for use with the following devices and options: COMPACT C 1600-12 COMPACT C 2600-24 COMPACT C 4000-48 Temperature sensor CT-35 AC cable cover CFC-01 Remote Control RCC-01
Résumé du contenu de la page N° 5
STUDER INNOTEC COMPACT During operation of COMPACT, high tensions are generated at the connections and inside of the appliance which could be deadly fatal. Work on the appliance and on the installation should only be carried out by qualified and trained personnel. The whole installation connected with the COMPACT must comply with the respective valid codes and ordinances. Persons without the written authorization from Studer INNO
Résumé du contenu de la page N° 6
STUDER INNOTEC COMPACT 2 Introduction The COMPACT is a sine wave inverter with integrated battery charger and solar charger controller with many additional functions, it has been developed to be used as stand-alone (independent of a grid-system) AC provider, or as continuous / break-free current supply provider. 2.1 Principle schematic AC IN AC OUT 10nF 1uF L L 100nF Input PE Output PE 230Vac 230Vac N N 10nF 4x2,7M Ω Filter AUX. C
Résumé du contenu de la page N° 7
STUDER INNOTEC COMPACT 2.2.4 The solar charge controller (optional) With the built-in solar charge controller, the COMPACT is a complete solar-power-center. In a solar installation this controller ensures that the batteries are charged correctly. With the COMPACT, batteries can be charged with a generator and with the solar modules at the same time. The charging of batteries with both energy sources is carried out fully automatical
Résumé du contenu de la page N° 8
STUDER INNOTEC COMPACT 2.3.3 Parallel- Series Connection 12V 12V 12V 12V C 2600-24 3 Assembly 3.1 Place of assembly The location of the COMPACT must be chosen by the following criteria: Protection from unauthorized handling. Dry dust free room, no condensation. Never install directly over the battery and never in a cabinet together with the batteries. Keep ventilation holes free. The ventilation of COMPACT is designed in such
Résumé du contenu de la page N° 9
STUDER INNOTEC COMPACT 3.3.2 Protection cover for the terminals connections The protection is available as an option (Order ref. CFC-01) and avoid to do wrong hazardous connection on the terminals 230Vac. It mounted with strain relief clamps for the cable. 3.4 Connecting Plan / Front side M AL N O Don't open before Caution: Check battery disconnect line polarity (+/-) before connecting! Remote and battery Pow
Résumé du contenu de la page N° 10
STUDER INNOTEC COMPACT G Aux. Contact Connecting terminal for Auxiliary Contact H AC Input Connecting terminal for AC-input. Located directly above this terminal is the automatic safety cut-out for this terminal. J ID Plate Identification plate with Technical data and Serial number K AC Output Conn
Résumé du contenu de la page N° 11
STUDER INNOTEC COMPACT 3.5.4 Connection the 230Vac Input (AC INPUT) The 230V-supply from network or from a generator must be connected to the screw terminals AC 2 INPUT. For this use a 3-core cable with a conductor cross section of 2.5mm . Connections are marked as follows “N“ Neutral, “PE“ Earth, “L“ Live. 3.5.5 Connect the solar modules: SOLAR +/- (Only for solar option) Solar modules are connected on these terminals. Under no
Résumé du contenu de la page N° 12
STUDER INNOTEC COMPACT 4 Operating 4.1 Display and operating control elements POWER Inverter output MONITOR power Charge [%] Charger - Inverter current 200 160 [A] 130 INPUT LIMIT CHARGER TRANSFER STANDBY 70 100 60 80 50 60 40 40 30 20 16A 70A 230V 20W 20 10 23 24 10 5 25 0 26 0 22 150V OFF AC IN 8 AC OUT 1 7 CHARGER INVERTER 2 9 20 SOLAR CHARGE RESET ALARM 3 Lock (select) 10 EQUALIZE 14 Over Temp Overload 11 4 15 Program 12
Résumé du contenu de la page N° 13
STUDER INNOTEC COMPACT 4.2 Light Emitting Diodes LED Marking LED lit LED blinks 1 AC IN Voltage corresponding to self- Voltage, outside of the self- adjusted values is at the AC IN adjusted values is at the AC IN input. input. 2 CHARGER Battery Charger is working The input voltage is out value (voltage or frequency) 3 SOLAR Connected solar modules are CHARGE delivering energy 4 Program Programming mode for Aux. Contact 5
Résumé du contenu de la page N° 14
STUDER INNOTEC COMPACT 4.5 The Inverter An Inverter is built in the COMPACT, which generates a sinusoidal alternating voltage of a very high quality. With this Inverter any alternating voltage consuming device 230Vac up to the nominal power of your COMPACT can be operated. Thanks to the generous dimensioning of the COMPACT, you can operate appliances requiring higher power than the nominal power of the COMPACT for a short time. Th
Résumé du contenu de la page N° 15
STUDER INNOTEC COMPACT 4.6 The Battery charger 4.6.1 Cycle of charge The full automatic COMPACT Battery Charger is adjusted at the factory so that most lead-acid and lead-gel batteries can be charged to the maximum. As soon as the minimum alternating voltage for the AC IN set on the Turning Knob 23 is available at the input (LED 1 AC IN is lit), the Battery Charger is switched on automatically (LED 2 CHARGER is lit). The battery i
Résumé du contenu de la page N° 16
STUDER INNOTEC COMPACT the OUTPUT less it’s give to the charger. Priority to the OUTPUT. When the power sharing is used the LED 200% (red) is lit to point out that’s the charge is limited. Caution: If the power use on the OUTPUT is higher than the value of the INPUT LIMIT (26) the COMPACT limits the current, then the generator means to stop or the circuit breaker before means to break. In option, a remote control (RPS-01, 20m
Résumé du contenu de la page N° 17
STUDER INNOTEC COMPACT The Transfer system is protected against overload with an automatic safety fuse on the AC Input side of the COMPACT. If the system has been overloaded the button/pin of the fuse will pop-out. To put the automatic safety system back in to operating you must push this pin back. Note: In the Inverter operation, The COMPACT generates a true sinusoidal and quartz stabilized output voltage. When, however the COMPA
Résumé du contenu de la page N° 18
STUDER INNOTEC COMPACT 4.9 The Multifunctional Contact In the COMPACT there is a built-in programmable power relay. The potential-free change-over contact (NO – NC) of this power relay is connected to the screw terminal AUX CONTACT. Maximum Contact load: -230Vac /16Amp-30Vdc/1A ! With the Push Button 21 „AUXILIARY CONTACT“ the contact can be manually switched on or off independent of programming and the operating situation. The LE
Résumé du contenu de la page N° 19
STUDER INNOTEC COMPACT Caution: No external voltage should be connected to this Input Control. 4.11 The Temperature sensor Operating voltage of lead-acid batteries change depends on the temperature. To correct the operating voltages according to the actual temperatures, a temperature sensor can be connected to the COMPACT. The compensation through the sensor is –3mV/°C/Cell. Order Number: CT-35 Dimensions: H x B x T / 58 x 5
Résumé du contenu de la page N° 20
STUDER INNOTEC COMPACT 5.3.2 Set the voltage and timing threshold 3 RESET ALARM 20 lock The programming is done in accordance with the following steps: 14 10 Over Temp Push and hold down, the Push Button 21 11 Overload 15 4 (Program) and the Push Button 19 12 Batt Low/High (Change status) for minimum 2 seconds 5 16 simultaneously. 6 13 OFF With the Push Button 20 (select) select 17 with of the battery level and the absorption