Résumé du contenu de la page N° 1
INSIGHT RANGE HOOD
KB-0333K
Résumé du contenu de la page N° 2
FOR CUSTOMER ASSISTANCE To aid in reporting this range hood, please record below the model number and serial number located on the unit. We also suggest you record all the information listed and retain for future reference. MODEL NUMBER SERIAL NUMBER DATE OF PURCHASE / / DEALER TELEPHONE SERVICER TELEPHONE TO PHONE: DIAL 1-800-BE-SHARP (237-4277) for: SERVICE (for your nearest Sharp Authorized Servicer) PARTS (for your authorized parts distributor) DIAL
Résumé du contenu de la page N° 3
CONSUMER LIMITED WARRANTY SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product (the “Product”), when shipped in its original container, will be free from defective workmanship and materials, and agrees that it will, at its option, either repair the defect or replace the defective Product or part thereof with a new or remanufactured equivalent at no charge to the purchaser for parts or labor for the period(s) set forth below. This warranty does n
Résumé du contenu de la page N° 4
IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING TO REDUCE THE RISK OF INJURY TO PERSONS FOR DOMESTIC COOKING ONLY IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:* WARNING 1. SMOTHER FLAMES with a close-fitting lid, cookie TO REDUCE THE RISK OF FIRE, ELECTRIC sheet or metal tray, then turn off the burner. BE SHOCK OR INJURY TO PERSONS, OBSERVE THE CAREFUL TO PREVENT BURNS. If the flames do FOLLOWING: not go out immediately, EVACUATE AND CALL THE 1. Use th
Résumé du contenu de la page N° 5
PREPARE HOOD LOCATION 1 Determine whether hood will discharge vertically (3 1⁄4” 1 3 / 4 " X 1 0 " WO O D S HI MS x 10” or 7” round), horizontally (3 1⁄4” x 10” only) or (R e c e s se d - b o t to m H O R I Z O N T A L D U C T I N G be non-ducted. For vertical or horizontal discharge, run ca b i n e ts o n l y) C AB I NE T F R O NT ductwork between the hood location and a roof cap or wall 1 3 / 8 " / 4 " cap. For best results, use a minimum number of transitions and elbows. 3 H ORI Z O NT A
Résumé du contenu de la page N° 6
PREPARE THE HOOD 1 Remove 7” Round NON-DUCTED INSTALLATION - Skip to page 8. Duct Plate from top The following Steps (6 thru 14) are for DUCTED of hood. Set duct INSTALLATION ONLY. plate aside - with mounting screws. 6 Remove Light Panel - held in place with (5) #8 screws. Disconnect l ight assembly w i r e h a r n e s s (white connector). 2 R e m o v e t a p e holding Filters in place. Pull down on filter tabs or 7 Remove Air Chute finger holes and - held in place with lift
Résumé du contenu de la page N° 7
PREPARE THE HOOD 10 Re-install air chute and screw, re-connect wire harness 13 3 1⁄4” x 10” Ducted Discharge Only: Remove tape from and replace light panel. damper flap and attach Damper/Duct Connector over knockout opening with screws removed in Step 4 under Note: Be careful not to trap wires between Support Fin “PREPARE THE HOOD”. Make sure damper Pivot is and light panel. nearest to top/back edge of hood. 11 Remove appropriate Duct Knockout(s) from top or back of hood. 14 7” Round Duct
Résumé du contenu de la page N° 8
PREPARE THE HOOD 5. Check that wheel is properly positioned as shown. Non-Ducted Installations Only: Press Sections into place if necessary. Make sure wheel Requires a Performance Ring to be attached to the blower ® turns freely. wheel. The Performance Ring is packed behind the Teflon - Coated Bottom Cover. Note: For information on non-ducted filters, see page 9. To install ring: 1. Remove Retaining Ring using a flat blade screwdriver. BLOWER SMALL DIAMETER RETAINING RING WHEEL EN
Résumé du contenu de la page N° 9
INSTALL HOOD 1 Hang hood from (4) mounting screws. Slide hood towards 4 Install (2) PAR20, 50 W Maximum Halogen Bulbs or wall until mounting screws are engaged in narrow end of (2) R16, 40 W Maximum Incandescent Bulbs. Purchase (4) keyholes. Tighten mounting screws securely. A long bulbs separately. screwdriver works best. 5 Replace filters, turn on power at service panel and test for 2 Replace bottom cover. proper operation. 3 Connect ductwork to hood. Use duct tape to make joints secure an
Résumé du contenu de la page N° 10
OPERATING 3 1 2 4 1 FAN There are four fan speeds from low (1) to high (4). HEAT SENSOR Push any button to select one of the four fan speeds. Press Your Sharp Insight Range Hood is equipped with an advanced another button to change fan speed. Push the same button Heat Sensor. to turn the fan off. A light above each fan button indicates The Sensor monitors the temperature and automatically the fan speed. adjusts the fan to the appropriate setting. 2 LIGHT Press the ON/OFF button and lights
Résumé du contenu de la page N° 11
CLEANING To clean hood: Remove filters. Use a damp cloth and WARNING To reduce the risk of electric shock, discon- a mild detergent to wipe all grease-laden surfaces. Do not nect from power supply before cleaning. use abrasive cloth, steel wool pads or scouring powder on Aluminum mesh filters: Clean frequently using hot ® the Teflon -coated bottom cover or on any painted surface. water and a mild detergent. Filters are dishwasher safe. Use care when cleaning blower wheel - it must not becom
Résumé du contenu de la page N° 12
– This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc. SHARP ELECTRONICS CORPORATION • Sharp Plaza, Mahwah, New Jersey 07430-2135 PRINTED IN USA 626995B