ICI3000P
Inter-Check Point-Of-Sale
Monitoring System
Installation/Operation Manual
C1043M-A (2/96)
PELCO • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • (800) 289-9100 or (1-559) 292-1981
FAX (800) 289-9150 or (1-559) 292-3827
Résumé du contenu de la page N° 2
TABLE OF CONTENTS Section Page 1.0 WARNINGS ....................................................................................................................................... 1 2.0 SCOPE .............................................................................................................................................. 2 2.1 DESCRIPTION ........................................................................................................................ 2 3.0 INSTALLATION .......
Résumé du contenu de la page N° 3
6.0 HOT KEY SUMMARY LIST ............................................................................................................. 21 7.0 TROUBLESHOOTING .................................................................................................................... 23 8.0 POWER-UP PROCEDURE FOR THE ICI3000P ............................................................................ 24 9.0 SPECIFICATIONS ...................................................................................
Résumé du contenu de la page N° 4
(This page intentionally left blank.) iv Pelco Manual C1043M-A (2/96)
Résumé du contenu de la page N° 5
INSTALLATION/OPERATION MANUAL ® ICI3000P INTER-CHECK POINT-OF- SALE MONITORING SYSTEM 1.0 WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1.Installation and servicing should only be done by 4. Only use replacement parts recommended by qualified service personnel and conform to all PELCO. Local codes. 5.After replacement/repair of this unit’s electrical 2. Unless the unit is specifically marked as a NEMA components, conduct a resistance measurem
Résumé du contenu de la page N° 6
2.0 SCOPE 2.1 DESCRIPTION The information contained within this manual covers These units are point-of-sale (POS) monitoring devices the installation and operation of the Inter-Check capable of monitoring up to sixteen (16) POS termi- ICI3000P cash register interface system. Installation nals simultaneously with up to thirty-two (32) units in- should be in accordance with all applicable local and stalled at one time. Standard features include: fifteen national electric codes, using approved ma
Résumé du contenu de la page N° 7
3.0 INSTALLATION 7. To verify communication between your ICI1000PIM and the ICI3000P, press [I] on the 3.1 SETTING UP ICI1000PIM keyboard and the following will be displayed: PARAMETERS AND BENCH TESTING Poll initialized! Reg. polled = 1 1 Reg. answer! NOTE: Please familiarize yourself with the Reg. polled = 2 2 No reg. answer! information in this manual prior to installation Reg. polled = 3 3 No reg. answer! etc. and operation. Contact the customer's register dealer/installer pr
Résumé du contenu de la page N° 8
3.2 ICI3000WK INSTALLATION NOTE: Do not mount the Inter-Check unit until all connections are made and program- 1. Install an 18 AWG, 3-conductor shielded cable be- ming is complete. Video adjustments on the tween each RJ14 phone jack at each cash register. underside of the unit may need to be accessible Refer to Figure 2 for appropriate wiring configu- during initial setup. ration. NOTE: Do not power up the ICI3000P unit until all other connections have been made. Use only the transformer suppl
Résumé du contenu de la page N° 9
3.3 ICI3008/ICI3016 INSTALLATION 0000 1000 where 0 = ON and 1 = OFF (refer to Figure 8). Refer to Figure 1 for a typical ICI3000P configuration. 6. Connect the desired alarm outputs to any peripheral 1. Connect the 9-pin switcher interface cable (supplied equipment requiring a normally open contact. (Refer with the ICI3008/ICI3016 switcher) into the port to Figure 5 for pin assignment information.) labeled “RS 232” of the ICI3000P. 7. Connect an “IBM AT” compatible keyboard into the 2. Connect
Résumé du contenu de la page N° 10
12 34 567 8 1 2 3 4 5 6 7 8 O PE N OPEN - DI P S WI T CH DE S CRI P T I ON- Swi t c h # F unc t i on 1 Bank addr es s Bank Address 2 Bank addr es s Bank Address 3 Bank addr es s Bank Address 4 Bank addr es s Bank Address 5 l oop Loop Select se l e c t 6 baud Baud Rate Select r a t e se l e ct 7 NC NC 8 NC NC Co v e r NOTE: mu s t Cover must be removed to access this dip switch. beremov ed t o ac c e s s t his DI P S wi t c h * Loop = 0 CAMERAS 16- 31 Addr es s = 0001 VI D E O O UT 16 1 5 14 13 1
Résumé du contenu de la page N° 11
3.3.1 Alarm Pin-out Configuration For detailed 25-pin and 9-pin alarm pin-out configura- tion information, see Figure 5 below. 25-PIN CONNECTOR FOR ICI3016 9-PIN CONNECTOR FOR ICI3008 5 4 3 2 1 1 13 9 8 7 6 25 14 Pin # Alarm Output Pin # Alarm Output 1Alarm Output 1 1Alarm Output 5 2Alarm Output 2 2Alarm Output 7 3Alarm Output 3 3Alarm Output 6 4Alarm Output 4 4Alarm Output 8 5Alarm Output 5 5Alarm Output 1 6Alarm Output 6 6Alarm Output 3 7Alarm Output 7 7Alarm
Résumé du contenu de la page N° 12
3.4 EXTERNAL VIDEO ADJUSTMENTS 5. Adjust the video GAIN of the monitor by adjusting There are five potentiometer adjustments located on the the potentiometer labeled “G”. This should be turned bottom of the Inter-Check unit. These video text ad- all the way down for normal application. justments are for fine tuning only. Major adjustments should be done through the operating software. Use a 6. Use the two DIP switches labeled "C" to adjust the small tipped, nonmetallic screwdriver for adjusting
Résumé du contenu de la page N° 13
4.0 PROGRAMMING 4.1 REGISTER 1 OR 2 SELECT To enter the SELECT MENU press enter. The following This menu allows you to manually display the transaction menu will be displayed on monitor: data from a specific register on either Screen 1 (the left- hand side of the monitor) or Screen 2 (the right-hand side of the monitor). (See Figure 7.) To enter this menu, press [1]. The monitor will display: Screen 1 or 2? SELECT MENU Select the screen (1 or 2) on which you want your register 1. Register #
Résumé du contenu de la page N° 14
4.2.1 Operator Selection Using • Press [3] to select internal synchronization (no the Hot Key F2 video). To select a specific operator for monitoring while in the •Pressing F9 will enable you to select an external monitoring mode: camera from PELCO’s ICI3008/ICI3016 Inter- Check switchers. 1. Press [F2] After pressing F9, the following prompt will be displayed: 2. Select appropriate Screen # (no prompt is displayed): Enter select # Pressing [1] selects Screen 1 Pressing [2] selects Sc
Résumé du contenu de la page N° 15
4.6 AUTO CAMERA SEARCH ON/OFF 4.8 SYSTEM PROGRAM When enabled, this feature monitors your camera This menu is used for programming text displays; system’s sync generation. If your monitoring camera communication and printer parameters; clock features; loses power or is disconnected, the system will auto- camera selections and alarm dwell time. matically switch to the next camera for synchroniza- tion. If an active video is not detected, the system will To enter the System Menu, Press [8]. The
Résumé du contenu de la page N° 16
4.8.2 Number of Lines for Small Using the cursor control keys, move the block to the Screens 1 and 2 desired position on the monitor. Press [ENTER] to save. This feature enables you to select the number of data lines NOTE: Overlapping the two screens will result displayed on each screen. The difference between the in “clipping” of the displayed text. “small” and “large” screens is that you may reduce the number of lines displayed on the small screen, while the 4.8.4 Large Screen Position 1 or 2
Résumé du contenu de la page N° 17
4.8.6 Channel Program Menu Exception Follow Alarm Time This option is used to set the length of time the 4.8.6.1 Partyline Inter-Check unit will dwell on an exception when using the Exception Follow or Hot Key E. When Press [6]. The following prompt will be displayed: this option is selected, the video screen will dis- CHANNEL PROGRAM MENU play: 4. Group Poll List 5. Exception Follow Alarm Time Alarm Dwell = 10 6. Group Select Enter Alarm Dwell Time 0 - 255 4.8.6.2 Channel Program Menu Group
Résumé du contenu de la page N° 18
4.8.7 Printer Parameters 4.8.9 External Camera Select From this menu the baud rate for the auxiliary output port This feature selects the screen (1 or 2) to be used for may be adjusted to communicate with an optional serial controlling the Inter-Check switcher. The selected screen printer. The Inter-Check defaults to 9600 baud. will have an “S” displayed at the bottom. To edit the baud rate, press [7]. The following prompt • To change the settings, press [9]. The monitor will will appear: di
Résumé du contenu de la page N° 19
4.8.10 Shadow List Programming Example 1: Shadow List This list tells the 8- or 16-position Inter-Check Switcher REG CAM DWL which camera and POS terminal are linked together. It is 1. 115 also used to program sequential video switching. The [S] 2. 216 hotkey is used to turn switcher sequencing on and off. 3. 324 4. 462 Press [0]. A long list of numbers will scroll up the screen. 5. 5 9 The following prompt will appear: 30. 30 30 During sequencing, with the above parameters set, the 31. 31 31 f
Résumé du contenu de la page N° 20
4.9 EXCEPTIONS Exceptions are cash register transactions of special interest that can be programmed into the ICI3000P units. Typical transactions are VOID, REFUND, CASH PAID OUT and NO SALE. These types of transactions can then be used to alarm your VCR or other alarmable device for video recording. Exceptions can also be printed out on an external serial printer for immediate hard-copy evidence. NOTE: Exceptions can only be displayed on screen #2. Therefore, you cannot monitor a register or op