Résumé du contenu de la page N° 5
PRO-2200 Two Reader Module PRO22R2 Installation Guide 5 CAUTION IF ANY DAMAGE TO THE SHIPMENT IS NOTICED, A CLAIM MUST BE FILED WITH THE COMMERCIAL CARRIER RESPONSIBLE. CAUTION Electro-static discharge can damage CMOS integrated circuits and modules. To prevent damage always follow these procedures: Use static shield packaging and containers to transport all electronic components, including completed reader assemblies. Handle all ESD sensitive components at an approved static controlled workstat
Résumé du contenu de la page N° 6
6 Installation Guide PRO-2200 Two Reader Module PRO22R2 Disclaimer Product Liability; Mutual Indemnification In the event that a Customer receives a claim that a Product or any component thereof has caused personal injury or damage to property of others, Customer shall immediately notify Engineered Systems in writing of all such claims. Engineered Systems shall defend or settle such claims and shall indemnify and hold Customer harmless for any costs or damages including reasonable attorneys’ fee
Résumé du contenu de la page N° 7
PRO-2200 Two Reader Module PRO22R2 Installation Guide 7 Shipping Instructions To ship equipment back to Engineered Systems: 1. Contact the customer service department before returning equipment at 800-323-4576. When calling, please have available: A description of the problem or reason for returning the equipment. Original purchase order number, invoice number and if the unit is under warranty. A new purchase order number if the unit is not under warranty 2. Obtain the Return Authorizat
Résumé du contenu de la page N° 8
8 Installation Guide PRO-2200 Two Reader Module PRO22R2 Confidentiality All software, drawings, diagrams, specifications, catalogs, literature, manuals and other materials furnished by Engineered Systems relating to the design, use and service of the Products shall remain confidential and shall constitute proprietary rights of Engineered Systems and Customer agrees to treat such information as confidential. Customer shall acquire no rights in the design of the Products or the related materials e
Résumé du contenu de la page N° 9
PRO-2200 Two Reader Module PRO22R2 Installation Guide 9 Description The Two Reader Board provides support for up to two access control doors by providing connections for Wiegand or Clock/Data type readers, supervised inputs and relay outputs. This board can be rack mounted, in which case, only one edge is accessible for wiring. Mounting the board flat increases the amount of available I/O slightly but also significantly decreases the number of boards that can be mounted in one enclosure. The I/O
Résumé du contenu de la page N° 10
10 Installation Guide PRO-2200 Two Reader Module PRO22R2 Dipswitch Settings: S8 S7 S6 S5 S4 S3 S2 S1 SELECTION OF FFOF F OF F ON FO* ADDRESS 1 OF FFOF F ON F OFO2 F ADDRESS OF FFOF F ON F ONO3 ADDRESS OF FFON F OFOF FO4 F ADDRESS OF FFON F OFON FO5 ADDRESS OF FFON F ONOFO6 F ADDRESS OF FFON F ONONO7 ADDRESS ON FFOFOF F OF FO8 F ADDRESS OF FF OF Reserved ON FF O 9,600 BPS OF N OF 19,200 BPS ON N O 38,400 BPS* OFF Not Used* * = Default
Résumé du contenu de la page N° 11
PRO-2200 Two Reader Module PRO22R2 Installation Guide 11 LED Operation The Reader board uses two on-board LEDs D79 & D80 to provide status information during its Power-up sequence as well as normal operation. LED LED DESCRIPTION MODE D79 D80 OF NOp F Start Power-up, hardware setu ON FFOM Testing RA Power-up Sequence ON NOn Testing ROM and completing initializatio LED D79 flashes 4 times after FN LASH O Power-up is completed This is the processor heart-beat LED. It flashes once every second. A sh
Résumé du contenu de la page N° 12
12 Installation Guide PRO-2200 Two Reader Module PRO22R2 For Wiring to an RS-485 port: 1. TR+ is the plus side of the transmit and receive differential signal. 2. TR- is the negative side of the transmit and receive differential signal. 3. GND is the signal ground. The wiring for this signal is required and NOT optional. This signal must NOT be connected to chassis GND. 4. Use 24 AWG low capacitance, two twisted-pair, shielded cable (Belden 9842 or equivalent). + Orange/white stripe White/orange
Résumé du contenu de la page N° 13
PRO-2200 Two Reader Module PRO22R2 Installation Guide 13 Single Wire Reader LED Control Configuration High Tri-Stated Low LED Output-> Sn ingle Color LEDLf ED O Lf ED Of LED Of Bn i-Color LEDGf reen LED OBn oth LEDs Of Red LED O To fully utilize each reader port, a 6-conductor cable (18AWG) is required. Reader port configuration is set via host software. Alarm Contact Wiring Inputs 1 to 8 may be configured to use normally open or normally closed contacts and non-supervised or supervised (with st
Résumé du contenu de la page N° 14
14 Installation Guide PRO-2200 Two Reader Module PRO22R2 Relays 1 and 3 are rated for and normally used to control the door locks associated with readers 1 and 2 respectively. While Relays 1 and 3 are sized to handle the typical loads generated by electrical locks, load switching can cause abnormal contact wear and premature contact failure. Switching of inductive loads (i.e., strike) also causes EMI (electromagnetic interference) which may interfere with normal operation of other equip- ment. T
Résumé du contenu de la page N° 15
PRO-2200 Two Reader Module PRO22R2 Installation Guide 15 5. Connect wiring to alarm input sensors or install jumper wire as appropriate. 6. Connect relay output wiring as appropriate. 7. Connect communications wiring to the Intelligent Controller. 8. Recheck wiring for correct connections and continuity. 9. When all boards have been installed, connect the Power Supply Cord for proper connections and power. 10. Setup the panel controls using the host software. Specification The Two Reader is for
Résumé du contenu de la page N° 16
Reader 1 Reader 2 RS-485 Power 16 Installation Guide PRO-2200 Two Reader Module PRO22R2 Wiring Diagram for Connectors 1 through 7 Input 5 Short RED Door EOL 1 Two Reader Board Together* Status Switch BLACK Input 5 Common 2 WHITE Input 6 3 Egress 1 GREEN Input 6 Common EOL Push-Button 4 2 Switch Input 1 3 1 Input 1 Common Typical Connection 2 RED 1 Input 2 3 2 Input 2 Common 4 D77 3 Relay 1 NO S-4 5 Door Lock Suppressor 4 Relay 1 C 6 Relay 1 NC BLACK 7 1 Relay 2 NO 8 Separate 2 - Relay 2 C 9 Powe
Résumé du contenu de la page N° 17
PRO-2200 Two Reader Module PRO22R2 Installation Guide 17 Wiring Diagram for Connectors 6 through 10 Note: For N-485 Communication Connections, twist the blue pair together and use as the common; use the orange pair as your data pair, observing polarity. Connect the external drain shield to the appropriate earth ground on one end.
Résumé du contenu de la page N° 18
18 Installation Guide PRO-2200 Two Reader Module PRO22R2 NOTES
Résumé du contenu de la page N° 19
Résumé du contenu de la page N° 20
Honeywell Security & Data Collection 2700 Blankenbaker Pkwy, Suite 150 Louisville, KY 40299 (800) 675-3364 www.honeywellaccess.com
Résumé du contenu de la page N° 1
PRO-2200
Two Reader Module
Installation Manual
Part Number: PRO22R2
A division of Northern Computers, Inc.
TD1143 rev 0501
Résumé du contenu de la page N° 2
Résumé du contenu de la page N° 3
PRO-2200 Two Reader Module PRO22R2 Installation Guide 3 Contents Warnings and Cautions ........................................................................................4 Disclaimer...........................................................................................................6 Product Liability; Mutual Indemnification................................................................6 Unpacking Procedure .............................................................................
Résumé du contenu de la page N° 4
4 Installation Guide PRO-2200 Two Reader Module PRO22R2 Warnings and Cautions WARNING Before installation, TURN OFF the external circuit breaker which supplies power to the system. Before connecting the device to the power supply, verify that the output voltage is within specifications of the power supply. Do not apply power to the system until after the installation has been completed. Personal injury or death could occur, and the equipment could be damaged beyond repair, if this precaution is