TABLE OF CONTENTS USING DEVICE COMMANDS 25 ............................................... SYSTEM OVERVIEW 4 .............................................................. General 4 ............................................................................... PAGING FEATURE 27 ............................................................... A Partitioned System 4 .......................................................... SECURITY CODES 27 ........................................................
Résumé du contenu de la page N° 4
SYSTEM OVERVIEW General Congratulations on your ownership of a First Alert Professional Partitioned Security System. You've made a wise decision in choosing it, for it represents the latest in security protection technology today. This system offers you three forms of protection: burglary, fire and emergency. Your system consists of at least one keypad which provides control of system operation, and includes various sensors which provide perimeter and interior burglary protection, plus smoke or
Résumé du contenu de la page N° 5
SYSTEM OVERVIEW Burglary Protection Your system provides four modes of burglary protection: STAY, AWAY, INSTANT and MAXIMUM, and allows you to BYPASS selected zones while leaving the rest of the system armed. You must turn on or "arm" the burglary protection portion of your system before it will sense burglary alarms. The system also provides a CHIME mode, for alerting users to the opening of protected doors and windows while the system is disarmed. Refer to the other sections of this manual fo
Résumé du contenu de la page N° 6
SYSTEM OVERVIEW Alarms When an alarm occurs, both the keypad and external sounders sound, and the keypad displays the zone(s) causing the alarm. If your system is connected to a central monitoring station, an alarm message is also sent. To stop the alarm sounding, simply disarm the system. Memory of Alarm When an alarm condition occurs, the keypad displays the number(s) of the zone(s) that caused the problem, and displays the type of alarm (ex. FIRE, ALARM). It remains displayed until it is clea
Résumé du contenu de la page N° 7
Q ENTRY/EXIT DELAYS General Information Your system has preset time delays, known as exit delay and entry delay. Whenever you arm your system, exit delay gives you time to leave through the designated exit door without setting off an alarm. Exit delay begins immediately after entering any arming command, and applies to all modes of arming protection. Slow “beeps” will sound throughout the exit delay period, if programmed. Restarting Exit Delay While Armed: Your system may have been programmed t
Résumé du contenu de la page N° 8
ENTRY/EXIT DELAYS Exit Alarms Whenever you arm the system, the exit delay begins. If an entry/exit door or interior zone is faulted when the exit delay ends (e.g., exit door left open), the system sounds an alarm and starts the entry delay timer. If you disarm the system before the entry delay ends, the alarm To minimize false alarms sound stops and the message "CANCEL ALARM" or "CA" is displayed on the keypad, along sent to the alarm with a zone number indicating the faulted zone. No message is
Résumé du contenu de la page N° 9
ABOUT THE KEYPADS General Your keypads allow you to control all system functions. The keypads feature a telephone style (digital) keypad and a Liquid Crystal Display (LCD) which shows the nature and location of all occurrences. The keypads also feature a built-in sounder which will sound during alarms and troubles. The keypads also "beep" during certain system functions, such as during entry/exit delay times, in CHIME mode, and when depressing any of the keys (to acknowledge the key press). Ther
Résumé du contenu de la page N° 10
ABOUT THE KEYPADS ® NO AC AWAY First Alert BYPASS NOT READY ALARM STAY CHIME BAT AWAY NO AC ARMED CHECK INSTANT FIRE STAY CHIME INSTANT BAT ALARM BYPASS CHECK READY A B ARMED FIRE NOT READY A B ARMED READY C D READY C D OFF AWAY STAY 1 2 3 OFF AWAY STAY Professional OFF AWAY STAY 1 2 3 MAXIMUM TEST BYPASS 1 2 3 4 6 5 MAXIMUM TEST BYPASS TEST BYPASS MAXIMUM INSTANT CODE CHIME 4 5 6 6 4 5 7 8 9 CODE INSTANT CHIME INSTANT CODE CHIME 8 9 READY 7 7 8 9 0 # READY First Alert * READY First A
Résumé du contenu de la page N° 11
ABOUT THE KEYPADS Fixed-Word Keypad Displays AWAY All burglary zones, interior & perimeter, are armed. STAY Perimeter burglary zones, such as windows and doors AWAY NO AC STAY CHIME are armed. INSTANT BAT ALARM INSTANT Perimeter burglary zones armed and entry BYPASS CHECK NOT READY delay is turned off. FIRE BYPASS One or more burglary protection zones have STYLE A KEYPAD DISPLAY been bypassed. NOT READY Appears when burglary portion of the system is not NO AC ready for arming (due to one or mo
Résumé du contenu de la page N° 12
Q FUNCTIONS OF THE KEYPAD SEE TYPICAL ALPHA KEYPAD ON NEXT PAGE 10. CHIME KEY: Turns CHIME mode on and off. When on, the 1. DISPLAY WINDOW. Alpha Keypad: A 2-line, 32-character Liquid Crystal Display (LCD). Displays protection zone opening of windows or doors while the system is disarmed will identification, system status, and messages. sound 3 beeps at the keypad(s). Fixed-Word Keypad: Displays protection zone ID and system 11. READY KEY: Displays all open protection zones. status messages usi
Résumé du contenu de la page N° 13
FUNCTIONS OF THE KEYPAD 1 •••• DISARMED **** READY TO ARM 17 15 3 A B 14 ARMED 4 IMPORTANT!: READY C D 2 When entering codes and commands, STAY OFF AWAY sequential key depressions must be made 6 1 2 3 within 2 seconds of one another. If 2 MAXIMUM TEST BYPASS seconds elapses without a key depression, 5 4 5 6 the entry is aborted and must be repeated 7 CODE from its beginning. INSTANT CHIME 8 9 7 10 16 READY First Alert 0# * 9 Professional SHOWN WITH FLIP-DOWN KEY COVER 8 REMOVED 11 13 12 TYPIC
Résumé du contenu de la page N° 14
Q Q Q CHECKING FOR OPEN ZONES Before arming your system, all protected doors, windows and other protection zones must be Using the closed or bypassed (see BYPASSING section). Otherwise the keypad will display a "Not READY Key Ready" message. Using the READY key will display all zones that are faulted, making it easier for you to secure any open zones. To show faulted zones: DIS ARM ED - PRESS Note: Keypads light a green READY indicator when system TO SH OW FAUL TS is ready. If not lit, th
Résumé du contenu de la page N° 15
Q ARMING PERIMETER ONLY (With Entry Delay ON) Using the 3 Use this key when you are staying home, but might expect someone to use the entrance door later. STAY key When armed in STAY mode, the system will sound an alarm if a protected door or window is opened, but you may otherwise move freely throughout the premises. Late arrivals can enter through the entrance door without causing an alarm, but they must disarm the system within the entry delay period or an alarm will occur. Close all protecte
Résumé du contenu de la page N° 16
Q ARMING PERIMETER ONLY (With Entry Delay OFF) Using the Use this key when you are staying home and do not expect anyone to use the entrance door. 7 INSTANT Key When armed in INSTANT mode, the system will sound an alarm if a protected door or window is opened, but you may otherwise move freely throughout the premises. The alarm will also sound immediately if anyone opens the entrance door. Close all protected perimeter windows and doors before arming (see CHECKING FOR OPEN ZONES section). The g
Résumé du contenu de la page N° 17
ARMING ALL PROTECTION (With Entry Delay ON) Using the Use this key when no one will be staying on the premises. 2 AWAY Key When armed in AWAY mode, the system will sound an alarm if a protected door or window is opened, or if any movement is detected inside the premises. You may leave through the entrance door during the exit delay period without causing an alarm. You may also re-enter through the entrance door, but must disarm the system within the entry delay period or an alarm will occur. Clo
Résumé du contenu de la page N° 18
ARMING ALL PROTECTION (With Entry Delay ON) 2-Partition AWAY To arm both partitions, first make sure both partitions are READY TO ARM. Arming AWAY AWAY (Continued) 1. + 2 + 2 ENTER MASTER CODE THEN PRESS AWAY (Master Code) TWICE Example: 7 2 9 6 and press the AWAY key, then press the AWAY key again. The first press of AWAY arms the local partition, the 2. ARME D AWAY ** ** second press of AWAY arms the other (remote) partition. YOU MAY E XIT NOW The “Armed Away” display should appear, and r
Résumé du contenu de la page N° 19
ARMING ALL PROTECTION (With Entry Delay OFF) Using the Use this key when the premises will be vacant for extended periods of time such as vacations, Key etc., or when no one will be moving through protected interior areas. 4 MAXIMUM When armed in MAXIMUM mode, the system will sound an alarm if a protected door or window is opened, or if any movement is detected inside the premises. You may leave through the entrance door during the exit delay period without causing an alarm, but an alarm will b
Résumé du contenu de la page N° 20
DISARMING AND SILENCING ALARMS Using the Use the OFF key to disarm the system and to silence alarm and trouble sounds. See "SUMMARY OF AUDIBLE NOTIFICATIONS" section for information which will help you to 1 OFF Key distinguish between FIRE and BURGLARY alarm sounds. IMPORTANT: If you return and the main burglary sounder is on, DO NOT enter the premises, but call the police from a nearby safe location. If you return after an alarm has occurred and the main sounder has shut itself off, the keypad