Résumé du contenu de la page N° 1
ALL METAL MOTION
SENSOR LIGHT CONTROL
Model HD-9240
© 2003 DESA Specialty Products™ 595-5631-07
Résumé du contenu de la page N° 2
Contents Introduction ..................................................................................................3 Package Contents .....................................................................................4 Installation .....................................................................................................5 Wall Mount ...............................................................................................5 Eave Mount .......................................
Résumé du contenu de la page N° 3
Introduction Dear Consumer: ® We would like to thank you for purchasing this JourneyMan product. We at DESA Specialty Products™ feel that you have purchased the most durable motion sensor available today. This ® JourneyMan product will give you a lifetime worth of operation. We are so confident with the durability of this product that we are backing it with a Lifetime Warranty. Enhanced Performance Features ☞ Rugged gripping teeth and finger screw provide full three-dimension adjustment of sens
Résumé du contenu de la page N° 4
Package Contents Additional Items Needed • Motion Sensor Light Fixture • Phillips screwdriver • Ladder • Lens shield •2 Flood lamps, 150 Watts Maximum per lamp • Manual • Hardware Pack Fits All Junction Box Configurations 1 Gasket Circular 1 Hanger Horizontal rectangular 1 Universal adaptor plate 4Wire nuts 2 #6-32 X 3/4" (19 mm) screws Vertical rectangular (for small rectangular boxes) 2 #8-32 X 3/8" (10 mm) screws (fixture to universal adaptor) Octagon 4 #8-32 X 3/4" (19 mm) screws (for circul
Résumé du contenu de la page N° 5
Installation CAUTION: BEFORE STARTING THE INSTALLATION, TURN THE POWER OFF AT THE CIRCUIT BREAKER. If you want to use the Manual Override feature you will need to install the fixture on a circuit controlled by a switch. Wall Mount Eave Mount ❒ Loosen the thumbscrews holding the sensor ❒ Loosen the thumbscrews holding the sensor head and lampheads. head and lampheads. ❒ Adjust the various parts so that the fixture ❒ Adjust the various parts so that the fixture looks similar to this illustration.
Résumé du contenu de la page N° 6
Universal Adaptor Standard Wiring ® If you are mounting the JourneyMan fixture to a CAUTION: If you have not already turned the power off at the breaker or fuse, do so now. small rectangular box, you will need to use the universal adaptor as shown below. Other boxes Make sure the gasket is in place before connect- ing any wires. You may find it convenient to use may require the adaptor adjusted differently. the wire hanger provided to hold the fixture to the If you are using a standard octagon b
Résumé du contenu de la page N° 7
Controlling Non-Motion Sensing Fixtures ❒ When wiring to additional standard fixture ❒ This fixture is provided with a sensor rated only: Strip the motion sensor's red wire and for 1000W. Since the fixture is only rated 300W, connect to the standard light's black wire. Con- 700W of additional load may be controlled by nect all white wires together. Total fixture this sensor. ratings must not exceed 1000W (8.3 A). ❒ When determining what a fixture is rated for, NOTE: All wiring between fixtures s
Résumé du contenu de la page N° 8
Finish Mounting Specifications ® ❒ Align the JourneyMan base plate, gasket, and Range . . . . . . . . . . . . . . Up to 100 feet (30.5 m) with the junction box holes. Secure with mounting Range Boost On; up to 70 screws that fit your junction box. feet (21 m) with Range ❒ If not installed on a weatherproof box or if the Boost Off. (Varies with sur- adaptor plate was used, caulk between the rounding temperature). base plate and mounting surface with sili- Sensing Angle . . . . . . . . Up to 270°
Résumé du contenu de la page N° 9
Test and Adjustment 1 NOTES: When first turned on wait about 1 / 2 Range Boost OFF ON minutes for the circuitry to calibrate. Testing with Range Boost on during day- SENSITIVITY light may result in abnormal operation. TEST 1 5 20 ❒ Turn on the circuit breaker and light switch. ❒ Open the control access cover (on bottom of unit) MIN. MAX ON TIME by pulling down on the tab of the rubber cover. Sensor Bottom ❒ Turn the sensitivity control to the center of its adjustment, RANGE BOOST to OFF and t
Résumé du contenu de la page N° 10
Adjustments Continued . . . ❒ Loosen the wing screws, estimate the direction to aim the sensor and tighten the wing screws just enough to hold the sensor in place. ❒ Walk through the coverage area noting where you are when the lights turn on. Loosen the wing screws and readjust the sensor as necessary. Tighten the wing screws (finger tight) when you are satisfied with the coverage direction. Keep the sensor at least 1 inch (25 mm) from lamps and keep the controls on the bottom. ❒ Adjust SENSITIV
Résumé du contenu de la page N° 11
If the wide angle (270°) coverage is too wide for Maximum your application, you may need to install the lens Coverage Angle shield to reduce the coverage angle. Approx. area ❒ Decide which side of the lens you want to cover. 270° blocked by the ❒ Curve the shield as shown. Slide the shield lens shield (if down, under the two metal ribs of the case. used) Make sure the shield slides all the way down so the entire shield will lay directly against the lens. ❒ Slip the small protrusion behind the ve
Résumé du contenu de la page N° 12
Operation MANUAL MODE Mode: On-Time: Works: Day Night Test 5 Sec x x Manual Mode only works at Auto 1, 5 or 20 min. x night because daylight returns Manual Until Dawn* x the sensor to AUTO. Flip the light switch off for one * resets to Auto Mode at dawn. 1 Second OFF second then back on to toggle then... RANGE BOOST between AUTO and MANUAL MODE. Off On Turn Range Boost on for addi- Range Boost Manual Mode works with the tional coverage only if needed. ON-TIME switch in the 1, 5, or 20 minute po
Résumé du contenu de la page N° 13
Troubleshooting Guide SYMPTOM POSSIBLE CAUSE SYMPTOM POSSIBLE CAUSE Lights will 1. Light switch is turned off. Lights stay 1. A lamp is positioned too close to not come 2. Flood light is loose or burned out. on continu- the sensor or pointed at objects on. 3. Fuse is blown or circuit breaker is ously. that causes the sensor to trigger. turned off. (Aim the lamp away from the sen- 4. Daylight turnoff is in effect. (Re- sor or objects). check after dark). 2. Control is pointed at a heat source 5.
Résumé du contenu de la page N° 14
Lifetime Warranty This is a "Limited Warranty" which gives you specific legal rights. You may also have other rights which vary from state to state or province to province. ® For as long as you (the original purchaser) own this JourneyMan product, any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you. Light bulbs are not covered. To obtain a refund or a replacement, return the product to the place of purchase. Not Covered - Repair service, adjustm
Résumé du contenu de la page N° 15
CONTROL DE LUZ Y DETECTOR DE MOVIMIENTO TODO HECHO DE METAL Modelo HD-9240 595-5631-07 © 2003 DESA Specialty Products™ 595-5631-07 S -15-
Résumé du contenu de la page N° 16
Indice Introducción ............................................................................................... 17 Contenidos del Paquete ........................................................................ 18 Instalación ...................................................................................................19 Montaje en pared .................................................................................. 19 Montaje en alero ................................................
Résumé du contenu de la page N° 17
Introducción Querido consumidor: ® Deseamos agradecerle por haber comprado este producto JourneyMan . Quienes trabajamos para la DESA Specialty Products™ creemos que ha comprado el detector de movimiento más durable que ® existe actualmente. Este producto JourneyMan le ofrecerá un funcionamiento de por vida. Tenemos tanta confianza en la durabilidad de este producto que lo respaldamos con una garantía de por vida. Características Mejoradas de Rendimiento ☞ Los dientes fuertes de sujeción y
Résumé du contenu de la page N° 18
Contenidos del Paquete Artículos adicionales que se necesitan •Aparato de luz y detector de movimiento • Destornillador Phillips • Protección de la placa translúcida • Escalera •2 reflectores, 150 vatios máximo por lámpara • Manual Queda bien con todas las configuraciones de cajas de empalmes •Paquete de ferretería 1 empaquetadura Circular 1gancho Rectangular horizontal 1 placa adaptadora universal 4 conectores de cable 2 tornillos #6-32 x 19 mm. Rectangular vertical (para cajas pequeñas rectang
Résumé du contenu de la page N° 19
Instalación CUIDADO: ANTES DE COMENZAR LA INSTALACION, APAGUE LA CORRIENTE EN EL CORTACIRCUITOS Si usted desea usar el sobrecontrol manual usted deberá instalar el aparato en un circuito controlado por un interruptor. Montaje en pared Montaje en alero ❒ Afloje los tornillos de mano que sostienen el ❒ Afloje los tornillos de mano que sostienen el cabezal del detector y los cabezales de lámpara. cabezal del detector y los cabezales de lámpara. ❒ Ajuste las diferentes partes para que el aparato ❒ A
Résumé du contenu de la page N° 20
Adaptador Universal Cableado Estándar ® CUIDADO: Si todavía no ha desconectado la Si monta el JourneyMan sobre una caja pequeña alimentación en el cortacircuito o fusible, rectangular, usted deberá usar el adaptador univer- hágalo ahora. sal, como se muestra abajo. Otras cajas necesitarán que el adaptador se ajuste de forma diferente. Asegúrese que la empaquetadura esté en su sitio antes de conectar cualquier cable. Le puede ser Si usa una caja estándar octagonal, probablemente conveniente usar