Résumé du contenu de la page N° 1
Reference Guide
for the DS7400Xi (Ver. 4+)
Control/Communicator
Armed Perimeter Armed
Status Supervisory Status
1 2 34 56 78
Power Bell Silenced
Power
Trouble
Fire 16 Fire
91011 12 13 14 15
TEST WEEKLY
TEST WEEKLY
On On
1 23 Off 1 23 Off
Perimeter Perimeter
45 6 Only 456 Only
No No
78 9 Entry 789 Entry
Bypass Bypass
0 # 0 #
* *
System System
Reset Reset
DS7445/DS7445i DS7447/DS7447E
Keypad Quick Reference Guide
Turning On (arming) your System using the DS7445/DS7445i Commands for other System Fe
Résumé du contenu de la page N° 2
7.4 Fire Safety ..................................................................... 27 Table of Contents 7.4.1 If Installed in Family Residences ....................... 27 7.4.2 Having and Practicing an Escape Plan .............. 27 Keypad Quick Reference Guide ........................................ 1 7.4.3 Installation Considerations ................................ 27 1.0 Specifications ............................................................. 4 7.5 Personal Identification Numbers ....
Résumé du contenu de la page N° 3
10.16 Commercial Fire Mode Programming: Program Addresses (0545-2720, 5001-6920) .......... 69 Program Address (2733) ............................................. 48 10.41.1 Alpha Description Programming: A Worksheet ................................................... 70 10.17 Open/Close Report Control Programming: 10.42 Phone Number Programming: Program Address (3149) ............................................. 49 Program Addresses (3159, 3175, 3191) .................... 74 10.18 Open/Close
Résumé du contenu de la page N° 4
NOTE: Fire Systems installed under NFPA-72 or UL Listed Fire 1.0 Specifications Systems require the use of 18 AWG or larger wire. 1.1 Enclosure Housing 1.7 Communicator The standard enclosure is manufactured from 20 Guage (1.0 mm), cold-rolled steel, and measures 12.5 by 14.5 by 3 inch (31.8 by Will report to two phone numbers with full single, double and back- 36.8 by 7.6 cm) (HxWxD). A keyed lock is included, and this enclosure up reporting. Communicates in SIA (110 or 300 baud), 3/1, 3/1 E
Résumé du contenu de la page N° 5
1.15 Max. Load Currents Max. Load Currents Standby Alarm UL Installations 1.5 A 2.5 A Maximum Current By Output: Not to exceed the maximum load currents listed above in Standby or Alarm Aux. Power & Keypad (Combined) 1.0 A 1.0 A Option Power 1.0 A 1.0 A 1.16 Backup Battery Calculation Bell Output X 1.75 A Programmable Output 2 500 mA 500 mA � The following table is used to calculate the standby battery capacity required by NFPA when using the DS7400Xi: Loop Power + 500 mA 500 mA Quantity Device
Résumé du contenu de la page N° 6
� DS7447/DS7447E: Control Station. (15 Keypads max. per 1.18 Options system) � DS7412: RS232 Serial Interface module. The DS7447/DS7447E is an Alpha-Numeric LCD The DS7412 module allows the panel to send event keypad. It displays information on various control information, in an ASCII format, directly to a serial panel functions. A built-in sounder is used as an printer or computer. In addition, the interface allows interior warning device and to annunciate keystroke the direct connection of a c
Résumé du contenu de la page N° 7
� DS7460: Dual Zone Module (up to 60 per system. Requires a � DS9484: The DS9484 is a Remote Notification Appliance DS7430 Multiplex Expansion Module). Circuit (NAC) Power Supply designed to add four The DS7460 provides a means of monitoring additional NACs (NFPA 72 Class B, Style Y) to a conventional Normally Open or Normally Closed Fire Alarm Control Panel (FACP). When connected contacts. It reports their status to the control panel as to the Options Bus of the DS7400Xi, it can provide multip
Résumé du contenu de la page N° 8
� MX794 The MX794 is a Long Range Multiplex PIR intrusion 2.0 Enclosure Installation (DS7474) Detector with Self-test. The standard ranges The DS7400Xi control/communicator and the enclosure are are 80 ft. by 50 ft. (24.0 m by 15.0 m) and 200 ft. by 10 ft. shipped together. The control, however, still needs to be installed (61.0 m by 3.1 m). Requires a DS7430 and occupies into the enclosure. Hardware for mounting the enclosure to a wall, one multiplex zone. and the control to the enclosure is
Résumé du contenu de la page N° 9
Wiring The Battery Terminals and Wires are NOT Power Limited. A ¼ in. (6.4 mm) spacing must be maintained between the battery terminals, battery wiring and all other wiring. Battery wiring may not share the same conduit, conduit fittings or conduit knock-outs with other wiring. Option or Keypad Wires ¼ in. (6.4 mm) Minimum Battery Wires Output or Zone Wires To ensure proper spacing secure wires using Tie-Wraps or similar devices Only required if external batteries are used DS7400Xi ( 4+) Refere
Résumé du contenu de la page N° 10
3.0 Control Terminal Wiring TYPICAL BURGLAR AND FIRE WIRING Zone Loop + Zone Loop + Zone Loop + Aux. Power (—) Input Input Input or PO2 (terminal 5 or 7) – Z– L+ Z– L+ Z– L+ Before servicing, remove all power including the transformer, battery and phone line. A complete functional test in out ++ Power WARNING is required after any programming. – Alarm NO Incorrect connections may result in damage to the unit. NC CAUTION in++ out System is Power Limited except for Power – battery terminals. All w
Résumé du contenu de la page N° 11
4.0 Hardware Layout Example DS7416i Communications Module R B G Y + + + + – –12345678 – –123 4567 8 POWER BUS POWER BUS Keypads #11 - #15 must be connected to the Options Bus. Keypads #1 - #10 must DS7430 be connected to the Keypad Bus. Armed Arme d St at u s Status Po wer Power +– +– Fir e Fire + – + –12345678 +– + – 123 4567 8 Power Bus POWER BUS POWER BUS On On 1 23 Off 1 23 Off Perimeter Per im ete r On ly Only 456 45 6 No No 78 9 Entry 78 9 Entry DS7432 8-Input Bypass Byp ass 0 # 0 # DS740
Résumé du contenu de la page N° 12
5.0 System Worksheet Account Number Information Name Contact Person Address Voice Phone Number Panel Phone Number City, State, Zip Panel Answers Phone Armed Disar
Résumé du contenu de la page N° 13
5.0 System Worksheet (continued) PIN Worksheet Personal Identification Number Information Example PIN Information User Pin # Auth. Parti- Name # Level tions 002 1001 6 1, 2, 4 James L. PIN Information PIN Information PIN Information User Pin # Auth. Parti- Name User Pin # Auth. Parti- Name User Pin # Auth. Parti- Name # Level tions # Level tions # Level tions 067 001 034 035 068 002 036 069 003 037 0
Résumé du contenu de la page N° 14
5.0 System Worksheet (continued) PIN Worksheet Personal Identification Number Information PIN Information PIN Information PIN Information User Pin # Auth. Parti- Name User Pin # Auth. Parti- Name User Pin # Auth. Parti- Name # Level tions # Level tions # Level tions 100 134 168 135 169 101 170 102 136 137 171 103 172 104 138 173 139 105 174 106 140 175 141 107 176 108 142 177 143 109 178 110 144 179 145 111 180 112 146 181 147 113 182 114
Résumé du contenu de la page N° 15
5.0 System Worksheet (continued) Zone Location and Notes Zone Location and Notes Worksheet Example * = SZ: Single Zone Input MZ: Multiple Zone Input Type * Zone/Output Partition & Location IO: DS7465 Function # (see section 10.3) Zone # 1 SZ Zn Funct. 1 2, Kitchen Type * Zone/Output Partition & Location Type * Zone/Output Partition & Location Function #
Résumé du contenu de la page N° 16
5.0 System Worksheet (continued) Page 16 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide
Résumé du contenu de la page N° 17
5.0 System Worksheet (continued) DS7400Xi ( 4+) Reference Guide Copyright © 2007 Bosch Security Systems, Inc. P/N: F01U035325-01 Page 17
Résumé du contenu de la page N° 18
5.0 System Worksheet (continued) Zone Location and Notes Worksheet Page 18 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide
Résumé du contenu de la page N° 19
6.2 Zone Function Programming 6.0 Glossary 6.1 General Control Programming � Zone Function A Zone Function is the description of how a particular zone will � Normal Arming - [PIN] + [On]: If programmed, arms the entire behave (e.g. steady alarm output, bypassing allowed, alarm on system while allowing entry delays for entry/exit zones. short, trouble on open, perimeter instant). � Perimeter Instant Arming - [PIN] + [No Entry] [Perimeter Only]: If - There are many possible zone functions. Up to
Résumé du contenu de la page N° 20
� Entry/Exit Delay #2: This is a zone programmed to behave seconds. identical to the Entry/Exit Delay #1 zone function except that it - If the system is a combination fire and burglar alarm, the fire uses entry delay time #2 (address 4029). alarm has priority over the burglar alarm. NOTE: If both entry delays have been activated, the control will � Fire Zone with Verification : This zone is identical to a Fire Zone use the shorter entry delay. except that after the first alarm, it will perform