Table of Contents Page No. 1 Warnings & Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . .2 2 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Items Supplied . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 3 Installation Instructions and Required Controls . . . . . . . .4 View of Rotospray Pump with Components Labeled . . . . . . .5 4 Theory of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 5 O
Résumé du contenu de la page N° 3
1 Warnings and Precautions • OBSERVE ALL WARNINGS. READ and UNDERSTAND all instructions in the manual before attempting to install and operate this equipment. ® • This equipment has been designed and tested for use with Loctite anaerobic products. • DO NOT USE equipment for other than intended use. • BE SURE that all adhesives, solvents, or fluids used are chemically compatible with the wetted parts of the equipment. • ALWAYS READ the Material Safety Data Sheet(s) before using adhesives, sol
Résumé du contenu de la page N° 4
2 Introduction ® ® The Loctite Series 9000 Rotospray Pump will apply a metered amount of Loctite anaerobic products to a Rotospray centrifugal force dispensing head. The Loctite Series 9000 Rotospray Pump is pneumatically operated and needs a 4-way pneumatic valve to control the pneumatic signals. The Loctite Series 9000 Rotospray Pump is usually part of a system that consists of the following components: 1. A gravity reservoir to supply product to the Loctite Rotospray Pump. 2. The Loctite Ro
Résumé du contenu de la page N° 5
3 Installation Inspection Before Installation The Loctite Rotospray Pump was inspected before shipment. Check the items in the shipping container against the list on Page 3 of this Manual. After removing the items from the shipping container inspect them for visible damage. Promptly report any damaged or missing parts to both the shipper and your Loctite representative. CAUTION: DO NOT REMOVE ANY ITEMS THAT ARE SEALED IN PLASTIC BAGS UNTIL THEY ARE TO BE USED AS THEY MAY BECOME CONTAMINATED RESU
Résumé du contenu de la page N° 6
4 Installation, cont. STROKE ADJUSTER KNOB CONTROL AIR "DISPENSE" PORT CONTROL AIR "RETRACT" PORT PRODUCT INLET FITTING LOCKING RING PRODUCT OUTLET FITTING PUMP ASSEMBLY (983117) ACTUATOR ASSEMBLY (983116) MOUNTING BRACKET (983335) Fig. 1 View of the Pump with Component Labeled. 5
Résumé du contenu de la page N° 7
Résumé du contenu de la page N° 8
5 Operation Priming the Pump (first time use) 1. Set the pump stroke to maximum. 2. Move the pump piston to the fully retracted position. 3. Fill the reservoir with product. 4. Disconnect the 3/8-inch OD tube from the pump inlet. 5. Let the product flow to within 1/2-inch of the end of the 3/8-inch tube, then reconnect the tube to the pump inlet. 6. Cycle the pump. 7. Continue to cycle the pump until air-free product flows at the dispense point. Adjusting Pump Dispense Volume The black knob on
Résumé du contenu de la page N° 9
6 Maintenance Routine 1. Inspect air tubing, product tubing, and fittings for cracks, kinks or breaks and replace, as required. 2. Drain the air line filter bowl, if necessary. Idle Time 1. If the pump is in daily use, you do not need to service the pump or product tubing to prevent product curing unless a contaminant is introduced into the system. 2. The pump and tubing can be left idle for as long as one (1) month without curing under normal temperature (70° - 80°F). 3. If the pump is to be id
Résumé du contenu de la page N° 10
6 Maintenance, cont. Replacing The Pump Or Actuator Module The rotospray pump consists of a pump module (part no. 983117) and an actuator module (part no. 983116). In most cases, the pump module is the one replaced. WARNING: Failure to correctly change out the pump module(s) will result in DAMAGE. No tools are required to connect or disconnect the pump from actuator. If any forceful effort is required, the assembly is not correct and the instructions should be reviewed. To Disassemble 1. Shut of
Résumé du contenu de la page N° 11
7 Troubleshooting Possible problems and solutions for the Series 9000 Rotospray Pump. Troubleshooting Guide Problem Cause Solution No air supply. Pump does not dispense product Turn on air supply. and the Stroke Adjuster Knob Adjust air pressure to at least 60 Low air pressure. does not move when the pump psi. is cycled. Reset Stroke Adjuster Knob. Stroke Adjuster Knob set to zero stroke. Replace actuator. Pump air actuator defective. Replace control valve. Control valve faulty. Check program a
Résumé du contenu de la page N° 12
8 Replacement Parts and Assemblies The following is a list of recommended parts or assemblies that may be required to service the Series 9000 Pump: Item Description Loctite Part No. Qty. 1. Pump assembly 983117 1 2. Actuator Assembly 983116 1 3. Tubing 1/4-inch OD poly 981821 10 m (for pump outlet). 4. Tubing 3/8-inch OD poly 981866 10 m (for pump inlet). 5. Male connector, 1/4 T x 1/8 NPT, 991733 1 nylon (for pump outlet). 6. Male connector, 3/8 T x 1/4 NPT, 999635 1 nylon (for pump inlet). 7
Résumé du contenu de la page N° 13
9 Series 9000 Pump Rebuilding Program The Series 9000 Pump is not field serviceable. Our rebuilding process ensures that the pump is free of contaminants and assembled to proper specifications reducing the possibly of a premature failure or unsatisfactory performance with Loctite products. This is accomplished by: • Ultrasonically cleaning the parts in the proper solvents for a predetermined time. • Pretreating all the wetted components to ensure a passive surface. • Using proper replacement p
Résumé du contenu de la page N° 14
10 Specifications 2.50 .50 2.50 2.06 4.20 1.63 REF. .44 .38 1.50 .50 1.88 DIAMETER .34 DIAMETER 7/16 HEX 9.15 1.35 DIAMETER Fig. 4 Dimensions 13
Résumé du contenu de la page N° 15
13 Specifications, cont. Utilities Required: Compressed air: 60 psig to 90 psig, filtered to 5 microns, dry (no condensing moisture). Lubricated air not required. Dimensions: See Fig. 4 on page 13. Product Viscosity Range: 100 cp - 100,000 cp Cycle Rate: Two Cycle per second maximum. Amount of product dispensed per stroke: Minimum = 0.02 cc. Maximum = 0.40 cc. Weight: 1.7 lbs. Calculated Pressure Ratio for Loctite Part No. 983330 Series 9000 Rotospray Pump: Calculated Pressure Ratios Item Air cy
Résumé du contenu de la page N° 16
14 Equipment Warranty Loctite expressly warrants that all products referred to in this Instruction Manual under Loctite Series 9000 Rotospray Pump 983330 (hereafter called “Products”) shall be free from defects in materials and workmanship. Liability for Loctite shall be limited, at its option, to replacing those Products which are shown to be defective either in materials or workmanship or to credit to the purchaser the amount of the purchase price thereof (plus freight and insurance charges pa
Résumé du contenu de la page N° 17
Loctite Americas 1001 Trout Brook Crossing Rocky Hill, CT 06067-3910 Loctite Corporation One Northfield Plaza, 5600 Crooks Rd. Suite 105 Troy, Michigan 48098 Loctite Canada Inc. 2225 Meadowpine Blvd. Mississauga, Ontario L5N 7P2 Loctite Company de México, S.A. de C.V. Calzada de la Viga s/n, Fracc. Los Laureles Loc. Tulpetlac, C.P. 55090 Ecatepac de Morelos, Edo. de México México Loctite and 271 are trademarks of Loctite Corporation, U.S.A. © Copyright 1999. Loctite Corporation. All rights reser