Résumé du contenu de la page N° 1
Vivid910-hard-E.book Page 1 Monday, October 18, 2004 3:11 PM
NON-CONTACT 3D DIGITIZER
VIVID 9i/VI-9i
Instruction Manual (HARDWARE)
NOTE
The VI-9i is model name for Europe and the VIVID 9i is model name for other countries.
Please note that the VIVID 9i model name is intended only for reference with this manual.
Résumé du contenu de la page N° 2
Vivid910-hard-E.book Page 2 Monday, October 18, 2004 3:11 PM Safety Symbols The following symbols are used in this manual to prevent accidents which may occur as result of incorrect use of the instrument. Denotes a sentence regarding safety warning or note. Read the sentence carefully to ensure safe and correct use. Denotes a prohibited operation. The operation must never been performed. Denotes an instruction. The instruction must be strictly adhered to. Denotes an instruction. Disconnect th
Résumé du contenu de la page N° 3
Vivid910-hard-E.book Page 1 Monday, October 18, 2004 3:11 PM Safety Precautions When using this hardware, the following points must be strictly observed to ensure correct and safe use. After you have read this manual, keep it in a safe place so that it can be referred to easily whenever it is needed. Failure to adhere to the following points may result WARNING in death or serious injury. Do not use the VIVID 9i in places where flam- Do not disassemble or modify the VIVID 9i. Doing so may caus
Résumé du contenu de la page N° 4
Vivid910-hard-E.book Page 2 Monday, October 18, 2004 3:11 PM Laser Caution and Identification Label Laser Caution and Identification Label CAUTION LASER RADIATION DO NOT STARE INTO BEAM LASER STRAHLUNG NICHT IN DEN STRAHL SEHEN MAX 30mW 690nm CLASS 2 LASER PRODUCT Complied with IEC Publication 60825-1:1993, Amendment-2:2001 AVOID EXPOSURE Laser radiation is emitted CLASS 1 LASER PRODUCT from this aperture. Complies with 21 CFR Chapter 1. Subchopter J. KONICA MINOL
Résumé du contenu de la page N° 5
Vivid910-hard-E.book Page 3 Monday, October 18, 2004 3:11 PM Notes On Use • The VIVID 9i is designed for indoor use only, and should never be used outside. • This digitized has been calibrated at 20°C. We recommend that you use it environments where ambient tem- perature is 20°C (68°F). • Use an AC power source which is within ±10% of the rated voltage. • The VIVID 9i should be used within a temperature range of 10 to 40°C at a relative humidity of 65% or less. • Do not use the VIVID 9i in di
Résumé du contenu de la page N° 6
Vivid910-hard-E.book Page 4 Monday, October 18, 2004 3:11 PM Notes On Cleaning • If the VIVID 9i needs cleaning, wipe with a soft dry cloth. Never use solvents such as thinner or benzene. • If the lens or laser emitting window is soiled with sand or dust, blow off the dirt using a blower, and wipe them gently with a piece of cleaning paper dampened with cleaning agent. • In cases of malfunction, do not disassemble the VIVID 9i or attempt to repair it yourself. Contact the nearest KONICA MINOL
Résumé du contenu de la page N° 7
Vivid910-hard-E.book Page 5 Monday, October 18, 2004 3:11 PM Contents Safety Precautions........................................................................................................................................................................ 1 Laser Caution and Identification Label........................................................................................................................................ 2 Warning Label................................................
Résumé du contenu de la page N° 8
Vivid910-hard-E.book Page 6 Monday, October 18, 2004 3:11 PM 6
Résumé du contenu de la page N° 9
Vivid910-hard-E.book Page 7 Monday, October 18, 2004 3:11 PM Chapter 1 Before Using the Instrument 7
Résumé du contenu de la page N° 10
Vivid910-hard-E.book Page 8 Monday, October 18, 2004 3:11 PM Package Contents (Standard Accessories) Check that the following standard accessories are present. VIVID 9i Main Body Polygon Editing Tool (with USB protect key) White Balance Cap VI-A10 AC Power Cord SCSI Cable VI-A20 Laser Barrier (Half-pitch, D-sub, 50-pin male plug – 50-pin male plug) 8
Résumé du contenu de la page N° 11
Vivid910-hard-E.book Page 9 Monday, October 18, 2004 3:11 PM Package Contents (Standard Accessories) Lens Field Calibration System (3 types, TELE, MIDDLE, WIDE/ (Field Calibration System, Frame for Calibration with Lens Cap) System, Hex wrench (M5), 4 screws) Tripod Attachment Set (Tripod attachment, Hex wrench (M3), 4 screws) 9
Résumé du contenu de la page N° 12
Vivid910-hard-E.book Page 10 Monday, October 18, 2004 3:11 PM Optional Accessories When you need to purchase the following optional items, contact a KONICA MINOLTA SENSING-author- ized service facility. Rotary Stage Set Tripod/Panhead VI-B25 (Pan head, Tripod, Ball Adapter) 10
Résumé du contenu de la page N° 13
Vivid910-hard-E.book Page 11 Monday, October 18, 2004 3:11 PM System Configuration Standard Accessories Optional Accessories (A commercially available computer can be used) White Balance Cap AC Power Cord VI-A10 Polygon Editing Tool SCSI Cable VI-A20 VIVID 9i Main Body Computer Tripod Attachment Set Laser Barrier 3 types of lens Tripod/Panhead VI-B25 Field Calibration System Rotary Stage Set 11
Résumé du contenu de la page N° 14
Vivid910-hard-E.book Page 12 Monday, October 18, 2004 3:11 PM Names and Functions of Parts Main Body Handle Light-Receiving Lens Note Please keep the receiving lens cap and the laser barri- er place in place when you are not carrying out scan- ning. Dust and scratches on the laser and lens can ad- versely affect scanning pre- cision. Power Switch Laser Emitting Window WARNING AC Power Connector A laser beam is emit- ted from this window. SCSI Port Do not stare into this window. Rubber sup
Résumé du contenu de la page N° 15
Vivid910-hard-E.book Page 13 Monday, October 18, 2004 3:11 PM Names and Functions of Parts Operation Panel 2 FOCUS AUTO 1 MENU CANCEL SELECT ENTER 3 4 5 6 7 AUTO 1 FOCUS ..........................Focuses the image automatically. 2 (Near) / (Far)...........Focuses the image manually. indicates “far” and indicates “near”. 3 .........................................Press once to display the menu on the viewfinder. Press again to close the menu and return to the monitor image. CANCEL 4 .......
Résumé du contenu de la page N° 16
Vivid910-hard-E.book Page 14 Monday, October 18, 2004 3:11 PM Names and Functions of Parts 14
Résumé du contenu de la page N° 17
Vivid910-hard-E.book Page 15 Monday, October 18, 2004 3:11 PM Chapter 2 Preparation 15
Résumé du contenu de la page N° 18
Vivid910-hard-E.book Page 16 Monday, October 18, 2004 3:11 PM Connecting the AC Power Cord To ensure correct connection of the AC power cord, read the points given in WARNING and CAUTION care- fully. WARNING Always use the AC power cord supplied as a standard accessory with the VIVID 9i, and connect it to an AC outlet (100-240 V , 50-60 Hz). Failure to do so may damage the VIVID 9i, causing a fire or electric shock. Do not bend, twist or pull the AC power cord excessively. Do not place heavy
Résumé du contenu de la page N° 19
Vivid910-hard-E.book Page 17 Monday, October 18, 2004 3:11 PM Connecting the VIVID 9i to a Computer To operate the VIVID 9i from a computer using the Polygon Editing Tool, the VIVID 9i must be connected to the computer with an standard SCSI cable VI-A20. WARNING The computer must be operated correctly and safely according to its instruction manual. Memo • The standard SCSI cable has a 50-pin male plug (half-pitch, D-Sub) on both its ends. • It is also possible to use a commercially available
Résumé du contenu de la page N° 20
Vivid910-hard-E.book Page 18 Monday, October 18, 2004 3:11 PM Connecting the VIVID 9i to a Computer Setting the SCSI ID No. In order for the computer to recognize that the VIVID 9i is connected to the computer via the SCSI interface, a SCSI ID No. (0 to 6) must be set for the VIVID 9i. Memo SCSI ID No. 5 has been set as the default setting before shipment. Note If other devices are connected to the computer via the SCSI interface, make sure that the SCSI ID No. of the VIVID 9i differs from th