Résumé du contenu de la page N° 1
CE DECLARATION OF CONFORMITY
MONARCH INSTRUMENT
Instruction Manual
As Manufacturer:
Monarch Instrument
Division of Monarch International Inc.
15 Columbia Drive, Amherst NH 03031 USA
declares under Monarch’s sole responsibility that the product:
Pocket Laser Tach 200
to which this declaration relates is in conformity with the following directives and
standards when installed and operated in accordance with the user manual:
Directives: EMC 89/336/EEC
Standards: EMC: EN61326:1997
Electrical
Résumé du contenu de la page N° 2
SAFEGUARDS AND PRECAUTIONS 14.0 OPTIONS /ACCESSORIES T-5 Reflective Tape, 5 foot [1.5 m] roll, ½ inch [13 mm] wide RCA Remote Contact Assembly with 10 cm wheel, concave and convex tips CTE Concave/convex contact tips and 10 cm linear contact WARNING - This product emits a visible beam of laser wheel light. Avoid exposure to the laser radiation. The use of optical viewing aids (binoculars, for example) may 12 inch Wheel 12 inch circumference wheel for use with RCA increase the ocular hazard. C
Résumé du contenu de la page N° 3
12.0 BATTERIES TABLE OF CONTENTS TABLE OF CONTENTS When displayed, replace batteries. 1.0 OVERVIEW ............................................................................. 1 2.0 FEATURE LOCATIONS ............................................................ 1 3.0 LCD DISPLAY SYMBOLS ....................................................... 2 Remove battery 4.0 PLT200 SPECIFICATIONS ...................................................... 3 cover 5.0 PREPARATION FOR MEASUREMENT .................
Résumé du contenu de la page N° 4
1.0OVERVIEW 11.0 INPUT / OUTPUT The Pocket Laser Tach 200 is a precision hand-held multifunction Input: Accepts remote sensor or Tachometer, Ratemeter, Totalizer and Timer. It is programmable to display Remote Contact Assembly directly in Revs, Inches, Feet, Yards, Miles, Centimeters and Meters or (RCA). 1/8” (3.5mm) stereo function as a stopwatch or interval timer. Input / output sockets allow for phone plug. remote sensing and pulse output to external indicating devices. For ease of use,
Résumé du contenu de la page N° 5
10.0 MAKING MEASUREMENTS 3.0LCD DISPLAY SYMBOLS 10.1 Non-Contact Measurements Hand-held OR External Sensor (ROS shown) (Not shown: Light IRS-P, Laser MT-190P) 10.2 Direct Contact Measurements Rotational Linear (Use concave On Target Indicator. Blinks on whenever there is an input tip for small signal. Will appear to be solid on at higher frequencies. shafts) to RCA Low Battery icon. Indicates that the batteries are low and need to be replaced. Times Ten icon. Indicates that the value show
Résumé du contenu de la page N° 6
8. Save and 4.0PLT200 SPECIFICATIONS advance Laser Specifications: Classification: Class 3R (per IEC 60825-1 Ed 1.2 2001-8) 9. Exit Setup – DONE, then Units Complies with FDA performance standards for laser products except Ready to selected for deviations pursuant to Laser Notice No. 50, dated July 26, 2001. measure Maximum Laser Output: 3mW Unit will remember these settings (including lock on/off) even if turned off Pulse Duration: Continuous and back on. Laser Wavelength: 650 nm Beam Divergenc
Résumé du contenu de la page N° 7
Contact Specifications (continued): 9.0TIMER Mode Accuracy: Revs: ±0.05% of reading (RPM) or resolution limit 9.1 TIMER Setup (with no slippage) 1. Turn Power Last Units selected Linear: ±0.5% of reading or resolution limit (with no ON are displayed slippage) Contact Measurements Ranges: 1a. To toggle Lock TACHOMETER: On/Off Revolutions per Minute (RPM) 0.5 to 20,000 RPM Press and Hold Revolutions per Second (RPS) 0.0833 to 333.33 RPS Locked On Revolution per Hour (RPH) 30 to 999,990 RPH 2. Ente
Résumé du contenu de la page N° 8
Contact Measurements Ranges (continued): 8.2 TOTALizer Operation RATES: Wheel Circumference: Measure OR Yards per Hour 10cm: 3.281 to 131,233 YPH 12 in: 10.000 to 240,000 YPH Miles per Hour 10 cm: 0.002 to 74.564 MPH Press and hold Lock on 12 in: 0.006 to 136.36 MPH Recall Max Max Speed Centimeters per Second 10 cm: 0.084 to 3,333.3 CM/S 12 in: 0.21 to 3,048.0 CM/S Centimeters per Minute 10 cm: 5.000 to 200,000 CM/M 12 in: 15.240 to 365,760 CM/M Recall Min Min Speed Centimeters per Hour 10 cm: 3
Résumé du contenu de la page N° 9
TOTALizer Setup (continued): Display: 5 x 0.5” (12.7mm) numeric digits plus 5 Alpha-numeric LCD Batteries: 2 “AA” 1.5 V (DC) alkaline included 9. Enter selection NONE, 1, 2 or 3 (Note: Batteries are NOT rechargeable.) of number of decimal places Battery Life: 30 hours continuous typical with batteries provided External Input: 10. Select decimal OR Repeat until places desired decimal Absolute max: -0.3 V to 5 V (DC) places displayed Minimum: low below 1.2 V and high above 2 V (TTL c
Résumé du contenu de la page N° 10
6. Enter Different options displayed for 5.0PREPARATION FOR MEASUREMENT selection of Internal or External operation. 5.1 Non-Contact Preparation Units Internal or External ROS: External RCA: For Internal operation (Red laser) or External operation COUNT Rotational: REV using optional Remote Optical Sensor (ROS-Red LED). Only Linear: INCH, FEET, YARDS, CM, METER 1. Clean 2. Apply 1/2” Shaft square T-5 7. Select Units OR Repeat until Reflective desired Units tape displayed 8. Save and For Smal
Résumé du contenu de la page N° 11
2. 10 cm Wheel OR 3. 12 inch Wheel 8.0TOTALizer Mode 8.1 TOTALizer Setup 1. Turn Power Different messages displayed for Install with ON Internal or External operation. pin in shaft fully seated Tighten screw in slot. securely into flat Internal or External ROS: External RCA: Tighten on shaft. Last Units EXTRN, then scrolling screw. selected message, then last Units selected 5.3 Connecting External Sensors 1a. To toggle Lock On/ Off Press and Hold Locked On 2. Enter Setup Mode 3. Enter Last
Résumé du contenu de la page N° 12
11. Save and 6.0TACHometer Mode advance 6.1 TACHometer Setup 1. Turn Last Units selected are 12. Exit Setup – DONE, Power displayed Ready to USE CONTACT TIP or ON measure [wheel selected], then Units selected 1a. To toggle Lock On/Off Unit will remember these settings (including lock on/off) even if turned off Press and Hold and back on. Locked On 2. Enter 7.2 RATE Operation Setup Measure OR Mode 3. Enter Last Mode selected is selection displayed Press and hold Lock on of Mode Recall Max Max Spe
Résumé du contenu de la page N° 13
RATE Setup (continued): 7. Select Units OR Repeat until desired Units 6. Enter selection Rotational: C RPS, displayed of Units C RPM or C RPH 8. Save and Linear: IPS, IPM, IPH, FT/S, FT/M, FT/H, YPS, YPM, advance YPH, MPH, CM/S, CM/M, CM/H, M/SEC, M/MIN, M/H 7. Select Units OR Repeat until desired Units 9. Enter selection NONE, 1, 2 or 3 displayed of number of decimal places 8. Save and OR advance 10. Select decimal OR Repeat until places desired decimal Rotational Units Linear Units places di
Résumé du contenu de la page N° 14
6.2 TACHometer Operation 7.0RATE Mode NOTE: External Remote Contact Assembly (RCA) must be inserted into Measure OR input socket. 7.1 RATE Setup Press and hold Lock on 1. Turn EXTRN, then scrolling Recall Max Max Speed Power message, then last Units ON selected 1a. To toggle Lock Recall Min Min Speed On/Off Press and Hold Locked On 2. Enter If unit Locked Resets Max/Min Setup on: Mode 3. Enter Last Mode selected is Power OFF OR Automatic after 90 seconds selection displayed if unit not Locked on