Résumé du contenu de la page N° 1
The Chamberlain Group, Inc.
845 Larch Avenue
Elmhurst, Illinois 60126-1196
www.liftmaster.com
®
GARAGE DOOR OPENER
Model 3585CS 3/4HP
For Residential Use Only
Owner’s Manual
■ Please read this manual and the enclosed safety materials carefully!
■ Fasten the manual near the garage door after installation.
®
■ The door WILL NOT CLOSE unless the Protector System is connected and properly
aligned.
■ Periodic checks of the opener are required to ensure safe operation.
■ The model number
Résumé du contenu de la page N° 2
TABLE OF CONTENTS Introduction 2-5Adjustment 23-25 Safety symbol and signal word review ....................... 2 Adjust the travel limits .............................................. 23 Preparing your garage door ....................................... 3 Adjust the force ........................................................ 24 Tools needed .............................................................. 3 Test the safety reversal system ................................ 25 ® Planning .......
Résumé du contenu de la page N° 3
1 Preparing your garage door Before you begin: To prevent possible SERIOUS INJURY or DEATH: � Disable locks. • ALWAYS call a trained door systems technician if garage � Remove any ropes connected to garage door. door binds, sticks, or is out of balance. An unbalanced garage door may not reverse when required. � Complete the f ollowing test to make sure your • NEVER try to loosen, move or adjust garage door, door garage door is balanced and is not sticking or binding: springs, cables, pu
Résumé du contenu de la page N° 4
— — — — — — — — Planning Identify the type and height of your garage door. Survey your garage area to see if any of the conditions below apply to your installation. Additional materials may be required. You may find it helpful to refer back to this page and the accompanying illustrations as you proceed with the installation of your opener. FINISHED CEILING SECTIONAL DOOR INSTALLATION Support bracket & fastening hardware is required. Horizontal and vertical reinforcement See pag
Résumé du contenu de la page N° 5
LOCK LIGHT LOCK LIGHT Carton Inventory Your garage door opener is packaged in two cartons If anything is missing, carefully check the packing which contain the motor unit and all parts illustrated material. Parts may be stuck in the foam. Hardware for below. Accessories will depend on the model purchased. installation is also listed below. Belt Cap Retainer ® SECURITY ® SECURITY Remote Control 3-Button Remote Control 3-Button Remote Control Transmitter Visor Clip Styrofoam TM Smart Control
Résumé du contenu de la page N° 6
ASSEMBLY STEP 1 Attach the Rail to the Motor Unit To avoid SERIOUS damage to opener, ONLY use bolts/ To avoid installation difficulties, do not run the fasteners mounted in top of motor unit. garage door opener until instructed to do so. � Remove the bolt and lock nut from the top of the motor Washered Bolt 5/16"-18x1/2" unit. Lock Nut � Place rail onto the bolt mounted on the motor unit and Styrofoam Rail align the back hole with the hole in the top of the unit. USE ONLY THIS Hole TYPE AN
Résumé du contenu de la page N° 7
ASSEMBLY STEP 3 Attach the Belt Cap Retainer To avoid possible SERIOUS INJURY to fingers from moving � Position the belt cap retainer over the motor unit garage door opener: sprocket so the two holes in cap align with the two • ALWAYS keep hand clear of sprocket while operating holes in mounting plate. Attach with 8x3/8" hex screws opener. provided. • Securely attach sprocket cover BEFORE operating. You have now finished assembling your garage door opener. Please read the following warni
Résumé du contenu de la page N° 8
INSTALLATION STEP 1 Unfinished Ceiling Determine the Header Bracket OPTIONAL CEILING Location MOUNT FOR HEADER BRACKET Header Wall 2x4 Vertical Centerline To prevent possible SERIOUS INJURY or DEATH: of Garage Door • Header bracket MUST be RIGIDLY fastened to structural 2x4 Structural support on header wall or ceiling, otherwise garage door Supports might not reverse when required. DO NOT install header bracket over drywall. • Concrete anchors MUST be used if mounting header bracket or 2x
Résumé du contenu de la page N° 9
INSTALLATION STEP 2 Install the Header Bracket Wall Mounting Holes You can attach the header bracket either to the wall above the garage door, or to the ceiling. Follow the CEILING MOUNT ONLY The nail hole is for instructions which will work best for your particular positioning only. requirements. Do not install the header bracket over You must use lag screws UP to mount the header bracket. drywall. If installing into masonry, use concrete anchors (not provided). WALL HEADER BRACKET INSTALLA
Résumé du contenu de la page N° 10
INSTALLATION STEP 3 Attach the Rail to the Header Bracket � Position the opener on the garage floor below the header bracket. Use packing material as a protective base. NOTE: If the door spring is in the way you’ll need help. Have someone hold the opener securely on a temporary support to allow the rail to clear the Header Wall spring. � Position the rail bracket against the header bracket. Header Bracket � Align the bracket holes and join with a clevis pin as shown. Belt Pulley Bracket
Résumé du contenu de la page N° 11
INSTALLATION STEP 4 Position the Opener To prevent damage to garage door, rest garage door opener Follow instructions which apply to your door type as rail on 2x4 placed on top section of door. illustrated. SECTIONAL DOOR OR ONE-PIECE DOOR WITH TRACK A 2x4 laid flat is convenient for setting an ideal Rail door-to-rail distance. � Remove foam packaging. � Raise the opener onto a stepladder. You will need help at this point if the ladder is not tall enough. 2x4 is used to determine Door the
Résumé du contenu de la page N° 12
INSTALLATION STEP 5 Hang the Opener To avoid possible SERIOUS INJURY from a falling garage Three representative installations are shown. Yours may door opener, fasten it SECURELY to structural supports of the garage. Concrete anchors MUST be used if installing any be different. Hanging brackets should be angled brackets into masonry. (Figure 1) to provide rigid support. On finished ceilings (Figure 2 and Figure 3), attach a sturdy metal bracket to structural supports before installing the
Résumé du contenu de la page N° 13
LOCK LOCK LOCK LOCK LIGHT LIGHT INSTALLATION STEP 6 Install the Control Console To prevent possible SERIOUS INJURY or DEATH from Locate control console within sight of door, at a minimum electrocution: height of 5' (1.5 m) where small children cannot reach, • Be sure power is not connected BEFORE installing door away from moving parts of door and door hardware. If control. installing into drywall, drill 5/32" holes and use the • Connect ONLY to 24 VOLT low voltage wires. anchors provide
Résumé du contenu de la page N° 14
NOTICE INSTALLATION STEP 7 Install the Light To prevent possible OVERHEATING of the endpanel or light socket: � Press the release tabs on both sides of lens. Gently rotate lens back and downward until the lens hinge is • DO NOT use short neck or specialty light bulbs. in the fully open position. Do not remove the lens. • DO NOT use halogen bulbs. Use ONLY incandescent. � Install up to a 100 watt maximum light bulb in each To prevent damage to the opener: socket. Light bulb size should be A1
Résumé du contenu de la page N° 15
INSTALLATION STEP 9 Electrical Requirements To prevent possible SERIOUS INJURY or DEATH from To avoid installation difficulties, do not run the electrocution or fire: opener at this time. • Be sure power is not connected to the opener, and disconnect power to circuit BEFORE removing cover to To reduce the risk of electric shock, your garage door establish permanent wiring connection. opener has a grounding type plug with a third grounding • Garage door installation and wiring MUST be in c
Résumé du contenu de la page N° 16
INSTALLATION STEP 10 ® Install The Protector System Be sure power is not connected to the garage door opener BEFORE installing the safety reversing sensor. The safety reversing sensor must be connected and aligned correctly before the garage door opener will To prevent SERIOUS INJURY or DEATH from a closing move in the down direction. garage door: • Correctly connect and align the safety reversing sensor. IMPORTANT INFORMATION ABOUT THE SAFETY This required safety device MUST NOT be disab
Résumé du contenu de la page N° 17
INSTALLING THE BRACKETS Figure 1 DOOR TRACK MOUNT (RIGHT SIDE) Be sure power to the opener is disconnected. Install and align the brackets so the sensors will face each other across the garage door, with the beam no higher Door Track than 6" (15 cm) above the floor. They may be installed in one of three ways, as follows. Lip Indicator Garage door track installation (preferred): Light � Slip the curved arms over the rounded edge of each door track, with the curved arms facing the door. Sn
Résumé du contenu de la page N° 18
MOUNTING AND WIRING THE SAFETY REVERSING Figure 5 SENSORS Wing Nut 1/4"-20 � Slide a 1/4"-20x1/2" carriage bolt head into the slot on each sensor. Use wing nuts to fasten sensors to brackets, with lenses pointing toward each other across the door. Be sure the lens is not obstructed by Carriage Bolt a bracket extension (Figure 5). 1/4"-20x1/2" Lens � Finger tighten the wing nuts. � Run the wires from both sensors to the opener. Use TROUBLESHOOTING THE SAFETY REVERSING insulated staples
Résumé du contenu de la page N° 19
INSTALLATION STEP 11 Fasten the Door Bracket Fiberglass, aluminum or lightweight steel garage doors will Follow instructions which apply to your door type as require reinforcement BEFORE installation of door bracket. Contact your door manufacturer for reinforcement kit. illustrated below or on the following page. A horizontal reinforcement brace should be long enough to be secured to two or three vertical supports. A vertical reinforcement brace should cover the height of the top panel. He
Résumé du contenu de la page N° 20
ONE-PIECE DOORS Please read and comply with the warnings and reinforcement instructions on the previous page. They apply to one-piece doors also. � Center the door bracket on the top of the door, in line with the header bracket as shown. Mark either the left and right, or the top and bottom holes. � Metal Doors: Drill 3/16" pilot holes and fasten the bracket with the 1/4"-14x5/8" self-threading screws HARDWARE SHOWN ACTUAL SIZE provided. � Wood Doors: Drill 5/16" holes and use 5/16"x