Résumé du contenu de la page N° 1
LCD Projection Monitor
MODEL PLV-55WM1
Owner’s Manual
Résumé du contenu de la page N° 2
Table of Contents Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . .2 Computer Input . . . . . . . . . . . . . . . . . . . . . . . . .33 Input Source Selection (INPUT 1 / PC digital, AV HDCP) 33 To the Owner . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Input Source Selection (INPUT 2 / PC analog) 34 Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . .4 Computer System Selection 35 Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Résumé du contenu de la page N° 3
To the Owner Before operating this LCD Projection Monitor, read this Safety Precaution manual thoroughly and operate the LCD Projection Monitor properly. WARNING : TO REDUCE THE RISK OF FIRE OR ELECTRIC This LCD Projection Monitor provides many convenient SHOCK, DO NOT EXPOSE THIS APPLIANCE features and functions. Operating the LCD Projection Monitor TO RAIN OR MOISTURE. properly enables you to manage those features and maintains – Install the LCD Projection Monitor in a proper position. If
Résumé du contenu de la page N° 4
Safety Instructions All the safety and operating instructions should be read before Do not install the LCD Projection Monitor near the ventilation the product is operated. duct of air-conditioning equipment. Read all of the instructions given here and retain them for later This LCD Projection Monitor should be operated only from the use. Unplug this LCD Projection Monitor from AC power type of power source indicated on the marking label. If you supply before cleaning. Do not use liquid or aer
Résumé du contenu de la page N° 5
Compliance Federal Communication Commission Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interf
Résumé du contenu de la page N° 6
Features and Design This LCD Projection Monitor is designed with the most advanced technology for various use. This LCD Projection Monitor has a large screen and utilizes built-in multimedia features, a palette of 16.77 million colors, and matrix liquid crystal display (LCD) technology. ◆ 16 : 9 Wide Screen ◆ Power Management The LCD Projection Monitor employs 55" large-sized The Power management function reduces power screen and LCD panels (1280 x 720 resolution) of 16 : 9 consumption and main
Résumé du contenu de la page N° 7
Installation Installing the LCD Projection Monitor Placing and Settling the LCD Projection Monitor Air Circulation Openings on the cabinet are provided for ventilation, to CAUTION ensure reliable operation of the product and to protect it from overheating. Therefore, these openings must not be When placing the LCD Projection Monitor, the spaces for blocked or covered. ventilation must be maintained. CAUTION 0.3' Hot air is exhausted from the exhaust vent. When using (10cm) or installing the L
Résumé du contenu de la page N° 8
Part Names and Functions q w Front Press here to open the Front Cover and then the Front control and terminals appear as below. e r t LAMP ECO POWER REPLACE WARNING INPUT 5 (VIDEO CONFERENCE) (MONO) VIDEO L–AUDIO–R INPUT VOLUME+ RESET MENU SELECT 7 8 d e !4 !3 !2 !1 !0 o i u y q Projection Screen o MENU button Used to select the On-Screen Menu operation. (p21) w Front Panel and Indicators !0 INPUT button Used to select the input source. (p25, 26, 27, 33, 34) e LAMP REPLACE indicator Turn orang
Résumé du contenu de la page N° 9
Part Names and Functions Part Names and Functions Back q w e q NOTE: q Exhaust Vent ● This LCD Projection Monitor detects internal temperature and w Terminals and Connectors (p11) automatically controls the running speed of the cooling fans. e Power Cord Connector 9
Résumé du contenu de la page N° 10
Part Names and Functions Front Jacks INPUT 5 (VIDEO CONFERENCE) (MONO) VIDEO L–AUDIO–R INPUT RESET * MENU OK 7 q q Input 5 Connect video and audio output from video equipment to these jacks. (p17) ● VIDEO (VIDEO CONFERENCE) (RCA-type) ● AUDIO L (MONO) and R (RCA-type) RESET * A built-in micro processor which controls this unit may occasionally malfunction and need to be reset. This can be done by pressing the RESET button with a pen, which will shut down and restart the unit. Do not use th
Résumé du contenu de la page N° 11
Part Names and Functions Part Names and Functions Rear Terminals q w INPUT 1 INPUT 2 INPUT 3 (MONO) R–AUDIO–L (MONO) R–AUDIO–L ANALOG DIGITAL(DVI-D) AUDIO OUTPUT Y – Pb/Cb – Pr/Cr ANALOG G B R H/V V AUDIO e VIDEO (VIDEO CONFERENCE) INPUT 4 Y – Pb/Cb – Pr/Cr R–AUDIO–L (MONO) r VIDEO (VIDEO CONFERENCE) S-VIDEO SERIAL PORT y t u q INPUT 1 r INPUT 4 Connect computer (Digital DVI-D type) and audio outputs Connect component / video, s-video, and audio outputs to these terminals. (p16, 17) from vide
Résumé du contenu de la page N° 12
Part Names and Functions Remote Control q POWER ON-OFF button Turn the LCD Projection Monitor on or off. (p18) w LAMP CONTROL button Select the lamp mode. (p20, 44) LL e SCREEN button LAMP CONTROL Select the screen size. (p32, 41) AUTO PC !4 q LAMP w r Point (Upe e/ Downd d/ Left7/ Right8) buttons Select the item or adjust the value in the On-Screen Menu. These are also !3 MENU SCREEN e used to pan the image in the Digital zoom mode. (p41) t IMAGE button Selects the Image Level. (p29, 39)
Résumé du contenu de la page N° 13
Part Names and Functions Part Names and Functions Remote Control Operating Range Point the remote control toward the LCD Projection Monitor (Infrared Remote Receiver) whenever pressing any button. Maximum operating range for the remote control is about 16.4’ (5m) and 60° in front of the LCD Projection Monitor. 60° 16.4’ (5 m) Remote Control Batteries Installation Remove the battery Slide the batteries Replace the compartment lid. 12 3 compartment lid. into compartment. Two AA size batteries For
Résumé du contenu de la page N° 14
Part Names and Functions Remote Control Code This LCD Projection Monitor has 8 different remote control codes (Code 1 - Code 8). Switching remote control codes prevents remote control interference when operating several equipment at the same time. Change the remote control code of the LCD Projection Monitor first before changing that of the remote control. See “Remote control” in the Setting on page 43. With holding down the MENU button, press the IMAGE button. The code switches sequentially
Résumé du contenu de la page N° 15
Preparation Preparation Connecting the AC Power Cord This LCD Projection Monitor uses nominal input voltages of 100- 120 V or 200-240 V AC. This LCD Projection Monitor automatically selects the correct input voltage. It is designed to work with single-phase power systems having a grounded neutral conductor. To reduce the risk of an electrical shock, do not plug into any other type of the power system. Consult your authorized dealer or service station if you are not sure of the type of power be
Résumé du contenu de la page N° 16
Preparation Connecting to a Computer and Video Equipment (Video, S-Video) Computer (Digital/Analog) Video, S-Video Use a DVI cable (commercially available) for digital. Use a Video cable or a S-Video cable (commercially Use a VGA cable (Option) for analog. available). Use a VGA-BNC cable (commercially available) for RGB. IBM-compatible or Macintosh computer Video Equipment Monitor Audio Monitor Audio Audio Monitor Video Output Audio S-video Output Output Output Output Output Output Output Outp
Résumé du contenu de la page N° 17
Preparation Preparation Connecting to Video Equipment (Component, DVI compatible with HDCP) Component, DVI compatible with HDCP, Video Video Use a DVI cable (commercially available) for DVI compatible with Use a Video cable (commercially available) for video. HDCP. Use a Component cable or VGA-BNC cable (commercially available) for component. Use a Video cable (commercially available) for component. Rear Terminals Front Terminals Video Equipment Video Equipment DVI Video Audio Video/Component A
Résumé du contenu de la page N° 18
Basic Operation Turning On the LCD Projection Monitor Connect the LCD Projection Monitor's AC power cord into an Front Panel Remote Control 1 AC outlet and the POWER indicator turns into red. LL LAMP Press the POWER ON-OFF button on the front panel of the LCD CONTROL AUTO PC 2 ECO POWER Projection Monitor or the remote control. The cooling fans start LAMP to operate. The POWER indicator blinks green rapidly for 15 SCREEN MENU seconds. INPUT 5 RENCE) (MONO) VIDEO L–AUDIO–R INPUT SELECT The P
Résumé du contenu de la page N° 19
Basic Operation Basic Operation Sound Adjustment Remote Control Direct Operation FREEZE Volume VOLUME INPUT 1 Press the VOLUME +/– button on the front panel or on the remote + VOLUME +/– button control to adjust the volume. The volume dialog box appears on the MUTE INPUT 2 MUTE button screen for a few seconds. AUDIO-S INPUT 3 Press + button to turn up the volume and – button to turn it down. SURROUND INPUT 4 SURROUND button Mute INPUT 5 Press the MUTE button on the remote control to minimize th
Résumé du contenu de la page N° 20
Basic Operation Lamp Control Function Lamp mode can be selected from the following modes depending on Remote Control the program scenes and environments of using the LCD Projection Monitor. The lamp mode can be selected in the Setting menu as well. (p44) LL LAMP CONTROL AUTO PC LAMP LAMP CONTROL Display Icons: button MENU SCREEN Normal···· Normal brightness Auto···· The controlled brightness according to the input SELECT signal Eco1···· The controlled brightness according to the ambient FREE