Résumé du contenu de la page N° 1
INDEX
ALARM SEARCH
DISPLAY
WJ-HD500A
Digital Disk
REC REVIEW
EL-ZOOM
Recorder
GROUP PLAY PPAUSE
REC STOP
SELECT
REV
FWD
LOCK
REMOTO 1
2 3 4
ALARM
SET
SPOT
ALARM
MULTISCREEN
RESET
TIMER 5
6 7 8
+
MULTISCREEN
ALARM SELECT
SUSPEND 9 10
11 12
-
HDD
OPRATE
13
14 15
16
FULL
FS 16
Digital Disk Recorder
Operating Instructions
Model No. WJ-HD500A
Before attempting to connect or operate this product,
please read these instructions carefully and save this manual for future use.
FRANÇAIS ENGLISH
Résumé du contenu de la page N° 2
ENGLISH VERSION Caution: Before attempting to connect or operate this product, please read the label on the bottom. For U.S.A NOTE: This equipment has been tested and found to com- ply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to pro- vide reasonable protection against harmful interference CAUTION when the equipment is operated in a commercial environ- RISK OF ELECTRIC SHOCK ment. This equipment generates, uses, and can radiate
Résumé du contenu de la page N° 3
CONTENTS PREFACE ......................................................................... 4 Sequence Setup (Spot Monitor) ............................. 59 FEATURES ....................................................................... 4 Power on Status Setup ................................................. 60 PRECAUTIONS ................................................................ 5 Power on Setting (Multiscreen Monitor) .................. 60 MAJOR OPERATING CONTROLS AND Power on Se
Résumé du contenu de la page N° 4
PREFACE The WJ-HD500A Digital Disk Recorder is a combination of A multi-recording function records simultaneously several a Hard Disk Recorder with a Video Multiplexer; it is able to images from various applications; this enables you to record the images of up to sixteen sequentially controlled obtain reliable records by selecting the application which is video inputs on the built-in hard disk. best suited for your purpose. FEATURES • One recorder can handle sixteen video inputs, divid- • Easy i
Résumé du contenu de la page N° 5
PRECAUTIONS • Refer all work related to the installation of this • Do not operate the appliance beyond its specified product to qualified service personnel or system temperature, humidity or power source ratings. installers. Use the appliance at temperatures within +5°C - +45°C (41°F - 113°F) and a humidity below 85 %. • Do not block the ventilation opening or slots on the The input power source for this appliance is 120 V AC cover. 60 Hz. To prevent the appliance from overheating, place it at l
Résumé du contenu de la page N° 6
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS Front View etyu!0 !1 !2 !3!4 !5!6 !7 !8 !9 @0 rio STOP BPLAY/ PAUSE REC GROUP FS 16 SELECT LOCK REC STOP 1 2 3 4 REMOTE ALARM SET SPOT ALARM INDEX MULTISCREEN REC PREVIEW REV FWD RESET 5 6 7 8 TIMER w MULTISCREEN ALARM SEARCH ALARM SELECT EL-ZOOM 9 10 11 12 SUSPEND SETUP OPERATE HDD DISPLAY SEQUENCE /ESC COPY 13 14 15 16 Digital Disk FULL q DAYLIGHT SAVINGS Recorder WJ-HD A #1 #0 @9 @8 @7@6@5@4 @3 @2 @1 The LED indicates the status as follows. q
Résumé du contenu de la page N° 7
!1 Numeric Buttons (1 - 16) @0 Record Button (REC) These buttons are used for numeric input into the sys- Pressing this button will start the recording manually tem such as the video selection, password, etc. when the Timer parameter is set to OFF in the setup The indicator in the button lights up to indicate as menu. shown below. The indicator in the button lights up to indicate that the recording mode is selected. Green: The input is displayed on the monitor. @1 JogDial Yellow: The input is di
Résumé du contenu de la page N° 8
@9 Direction Buttons (CDA B) #0 Full Indicator (FULL) These buttons are used to select an area for a zoomed Lights to indicate when the available recording space image displayed on the Multiscreen Monitor. of the Disk Recorder (HDD) is running low. During the setup, these buttons are used to move the cursor position in the setup menu of the Disk Recorder. #1 Hard Disk Drive Indicator (HDD) Lights to indicate when the Hard Disk is activated. C: Downward D: Upward A: Left B: Right Rear View $3 $
Résumé du contenu de la page N° 9
$7 Alarm Port (ALARM) %1 Remote Port [REMOTE (WV-CU50)] This port accepts the alarm input from the associated This port is provided for controlling the Disk Recorder alarm sensors through either Normally Open or with the optional WV-CU50 Remote Controller. Normally Closed contacts. To connect to the controller, use a 6-conductor modular The pin assignment of the port is shown below. cable supplied as an accessory with the controller. %2 Gen-lock Output Connector (GEN-LOCK OUT) 1 13 This connecto
Résumé du contenu de la page N° 10
WV-CU50 Remote Controller *1 *2 *3 Remote Controller WV-CU50 SET LOCK LINK &1 1 2 3 4 *4 SPOT MULTISCREEN COPY *5 &2 5678 MULTISCREEN REC REMOTE SELECT PREVIEW &3 9 10 11 12 *6 &4 SEQUENCE EL-ZOOM (3 &5 13 14 15 16 &6 GROUP *7 SELECT STOP PLAY/ PAUSE REC &7 *8 *9 REV FWD INDEX &8 ALARM ALARM RESET SEARCH &9 (0 REC DISPLAY STOP (1 *0 (2 &1 Lock Button (LOCK) &3 Multiscreen Selection Button Toggles to enable or disable the button lock function on (MULTISCREEN SELECT) both front panels of the Dis
Résumé du contenu de la page N° 11
&6 Electronic Zoom Button (EL-ZOOM) *6 Direction Buttons (CDAB) Use this button to enter or exit the electronic zoom Use these buttons to select the desired area to be mode. zoomed on the Multiscreen Monitor. In the EL-ZOOM mode an image presently displayed in single spot can be enlarged and compressed on the C: Downward Multiscreen Monitor. D: Upward A: Left &7 Group Selection Button (GROUP SELECT) B: Right Selects the camera group from among group 1, 2, 3 and 4. *7 Stop Button (STOP) The LED w
Résumé du contenu de la page N° 12
FS FS 16 16 INSTALLATION The installations described below should be made by 4. Insert the absorbers on to the chassis as shown in the qualified service personnel or system installers. figure. 5. Place the hard disk on the chassis, then fix it with the four screws and sleeves with the earth lug as shown in Installing the Optional Hard Disk the figure. At the time of shipment from the factory, the WJ-HD500A Disk Recorder is equipped with one hard disk drive; an optional drive can be installed t
Résumé du contenu de la page N° 13
5. Place the Motion Detector Board on the Analog Board, Installing the Optional Motion as shown below, and plug in the boards. Detector Board The Motion Detector Board WJ-HDB501 is installed exclu- 6. Fix both boards with the 3 supplied screws, as shown sively in the WJ-HD500A Disk Recorder. below. 1. Unplug the power cord from the WJ-HD500A Digital Disk Recorder, or disconnect the plug from the AC out- let. Main Board 2. Remove the top cover of the Disk Recorder by remov- ing the 11 screws, a
Résumé du contenu de la page N° 14
10/100BASE-T 5. Connect one end of the supplied flat cable to the Installing the Optional Network Board brown-colored receptacle on the main board, as shown The Network Board WJ-HDB502 is installed exclusively in in the figure. the WJ-HD500A Disk Recorder. 1. Unplug the power cord from the WJ-HD500A Digital Main Board Disk Recorder, or disconnect the plug from the AC out- let. Flat Cable (Supplied) 2. Remove the top cover of the Disk Recorder by remov- ing the 11 screws, as shown in the figure
Résumé du contenu de la page N° 15
WJ-HD500A Digital Disk WJ-HD500A Recorder Digital Disk Recorder FS 16 16 FS 16 • • • • • • Mounting into the Rack The Disk Recorder can be mounted into the rack as described below. 1. Remove the four rubber feet by removing the four screws from the bottom of the Disk Recorder. Remove 4 rubber feet 2. Place the rack mounting brackets on both sides of the Disk Recorder and tighten with the four supplied screws (M4 X10). 3. Install the Disk Recorder with the rack mounting brack- ets in the rack,
Résumé du contenu de la page N° 16
CONNECTIONS Shown below are examples of system connections. 16 Cameras POWER ON OFF Spot Monitor STOP PLAY/ PAUSE REC GROUP FS 16 16 LOCK REC STOP SELECT 1 2 3 4 REMOTO ALARM SET SPOT ALARM REC PREVIEW INDEX RESET MULTISCREEN 5 6 7 8 REV FWD TIMER MULTISCREEN ALARM SEARCH ALARM SELECT EL-ZOOM SUSPEND 9 10 11 12 SET UP OPERATE HDD DISPLAY SEQUENCE /ESC COPY 13 14 15 16 Digital Disk FULL DAYLIGHT SAVINGS Recorder WJ-HD A Digital Disk Recorder WJ-HD500A POWER ON OFF M
Résumé du contenu de la page N° 17
Connection with the Camera Sites Connection with the Remote Controller Connect cameras (or camera site equipment) to the VIDEO IN connectors (1 to 16) on the rear of the Disk Recorder Connect the Remote Controller to the REMOTE port on the with the coaxial cable. rear of the Disk Recorder with the supplied modular cable. REMOTE (WV-CU50) 16 15 14 IN OUT 16 15 14 Remote Controller WV-CU50 Connection with the Monitors Connect the monitors to the SPOTOUT connector and MULTISCREENOUT connector
Résumé du contenu de la page N° 18
• The sequence timing can be assigned to one of the Alarm Port Connection recorders when the multiple Disk Recorders are The ALARM port can be used for connecting the alarm sen- equipped in the system. sor and alarm control switches. It is also used to synchro- Connect the CONTROL port and ALARM port as shown nize the sequence as shown below. below. Refer to the SEQ TIMING in the SEQUENCE SETUP • Connect the sensor switches to the ALARM port on the menu for further setting. rear of the Disk R
Résumé du contenu de la page N° 19
• Time adjustment can be enabled connecting with the Control Port Connection external device as shown below. The CONTROL port can be used for controlling the system with the outboard device as shown below. WJ-HD500A CONTROL Port 1 13 13 1 25 14 24 20 25 14 CONTROL Time Adjustment Output Pin Pin • The Extension Units are installed in the system for Designation Designation No. No. extending its disk capacity. Disk Recorder Error 1 Group Recording Output 14 Connect each thermal error output fro
Résumé du contenu de la page N° 20
Connection with the Uninterrupted Power Supply (UPS) • The figure shows an example of how to connect a UPS as protection against power failures. • When a power failure detect input is received from the UPS, the disk recorder's power failure process starts to process this signal to turn off its power supply. • When the power failure process is completed, the disk recorder outputs a signal to the UPS. • When the UPS receives the completion signal from the disk recorder, the disk recorder's power