Chapter 1: Outline 1 An FL-net module (JW-20FL5/20FLT, JW-50FL, FL-net board (Z-336J)) is an interface module use to connect a programmable controller (JW20H/30H, JW50H/70H/100H), J-board to an FL-net. FL-net is an open network that connects production equipment and controllers from multiple FA (factory automation) venders, to create a unified production process. This network works as an intermediary between information networks and produc- tion networks, and makes it possible to connect control
Résumé du contenu de la page N° 12
Chapter 2: Handling Precautions Make sure to follow the precautions bellow who using the JW-20FL5/20FLT, JW-50FL (hereafter referred to as this module) and Z-336J (hereafter referred to as this board). (1) Installation 2 - Do not install or store this unit in the following conditions. 1 Locations close to a heating element 2 Sudden temperature changes which may cause condensation 3 Corrosive or inflammable gas 4 Vibration or hard jolts - The minimum distance between nodes is specified in the r
Résumé du contenu de la page N° 13
1 2 1 2 Chapter 3: System Configuration [Connection example] Personal computer 10BASE5 coaxial cable (max. 500 m) Transceiver FL-net Terminator 3 J-board JW20H/30H JW50H/70H/100H Transceiver NC Hub cable RC 10BASE-T (max. 50 m) twisted pair cable JW-20FL5 Other (max. 100 m) Z-336J maker’s RC JW-50FL PC J-board JW50H/70H JW20H/30H /100H JW-20FLT Z-336J JW-50FL - A basic system (segment) configuration consists of a 10BASE5 coaxial cable between 10m and 500 m long with nodes connected to thi
Résumé du contenu de la page N° 14
Chapter 4: Name and Function of Each Part Chapter 4: Name and Function of Each Part 4-1 JW-20FL5 1Display panel 6Module No. switch (Factory setting: 0) 2Connector for programmer Connector for shield 4 4 switch for 10BASE5 ON 3Connector for 10BASE5 S H I E L D OFF 512 VDC power supply input terminal (Factory setting: ON) FG 7Reset switch (Front) (Rear) Name Function Display panel Displays the JW-20FL5 operating status using LEDs. LN Lights when communicating normally. TX
Résumé du contenu de la page N° 15
Chapter 4: Name and Function of Each Part 4-2 JW-20FLT 1Display panel 5Module No. switch 2Connector for programmer (Factory setting: 0) 4 Connector for shield switch for 10BASE-T ON S H I 4 3Connector for 10BASE-T E L D OFF (Factory setting: ON) 6Reset switch (Front) (Rear) Name Function Display panel Displays the JW-20FLT operating status using LEDs. LN Lights when communicating normally. TX Blink at transmitting data. RX Blink at receiving data. 12 V Cannot be used with the
Résumé du contenu de la page N° 16
Chapter 4: Name and Function of Each Part 4-3 Z-336J 9Switch SWA 0Switch SW1 8Reset switch Factory setting Factory setting : ON : ON 7Module No. switch SW4 (Factory setting: 0) 2Connector for programmer 1Display panel 3Connector for 10BASE-T 4 4Connector for 10BASE5 5Switch SW6 612 VDC power supply input terminal (Factory setting: ON) Name Function Display panel Displays this board operating status using LEDs. LN Ligh
Résumé du contenu de la page N° 17
Chapter 4: Name and Function of Each Part 4-4 JW-50FL JW-50FL LNK S0 1 LED indicator TX S1 RX S2 DC12V S3 S4 TEST S5 PER S6 HER S7 2 Connector for programmer 8 Switch SW3 (Factory setting: 0) 4 3 Connector for 10BASE5 7 Switch SW3 (Factory setting: ON) 4 Connector for 10BASE-T 5 12 VDC power supply input terminal 6 Reset switch Name Function Display panel Displays the JW-50FL operating status using LEDs. LNK Lights at operating. Lights OFF at stopping. TX Blink at
Résumé du contenu de la page N° 18
Chapter 5: Installation Chapter 5: Installation 5-1 Installation of JW-20FL5/20FLT This section describes the installation procedures for the JW-20FL5/20FLT (hereafter referred to as the module) on the JW20H/30H basic rack panel. Turn off the power to the JW20H/30H. Set the module No. switch on the back of the module. (Back of the communication module) 5 Module No. switch Insert the mounting rib on the module into the rib insert holes on the JW20H/30H basic rack panel and push in. Then, tigh
Résumé du contenu de la page N° 19
Chapter 5: Installation 5-2 Installation of Z-336J Board dimensions and assembled dimensions of the Z-336J are shown below. Board dimensions 5 100 5 [Unit: mm] Boss hole: 4-φ4 The dimensions on the left do not include metal fittings. 170 180 5 5 110 Assembled dimensions [Unit: mm] 25.0 * CPU board (when Z-311J/312J is mounted) 21.6 D2 When installing the Z-336J under the CPU board. D D2 D2 15.0 In the case metal fixing A is used. * The CPU board can only be installed at the upper most position
Résumé du contenu de la page N° 20
Chapter 5: Installation This paragraph describes the maximum number of Z-336J boards to install on the J-board and allocation of I/O relays. Allocation of I/O relays When mounted on the Z-311J/312J See the next page. When mounted on the Z-313J See page 5-5. When mounted on the Z-511J See page 5-6. [1] Maximum number of boards to mount The Z-336J is a kind of communication board of the J-board. Maximum number of boards mounted on the J-board shall be the total number of communication boards m
Résumé du contenu de la page N° 1
Version 1.0
Produced in June 2002
Sharp Programmable Controller
Module name
JW-20FL5
JW-20FLT
JW-50FL
FL-net Z-336J
User's Manual
Résumé du contenu de la page N° 2
Thank you for purchasing the FL-net module (board) for use with the sharp programmable controller. JW-20FL5 (Installed PC) JW20H/30H FL-net module JW-20FLT JW-50FL JW50H/70H/100H FL-net board Z-336J J-board Please familiarize yourself with the module by reading this user's manual thoroughly. Keep this manual handy. We are confident that this manual will be helpful whenever you face a problem. In addition to this manual, the following manuals are available for your further study. - JW-20FL5/20FLT
Résumé du contenu de la page N° 3
Safety Precautions Read this manual and attached documents carefully before installation, operation, maintenance and check- ing in order to use the machine correctly. Understand all of the machine knowledge, safety information, and cautions before starting to use. In this instruction manual, safety precautions are ranked into "danger" and "caution" as follows. Danger : Wrong handling may possibly lead to death or heavy injury. Caution : Wrong handling may possibly lead to medium or light inju
Résumé du contenu de la page N° 4
3) Use Danger - Don't touch the terminal while the power is being supplied or you may have an electric shock. - Assemble the emergency stop circuit and interlock circuit outside of the programmable controller. Otherwise breakdown or accident damage of the machine may be caused by the trouble of the programmable controller. Caution - Change of program during operation, or "Run" or "stop" during operation should be done with particular care by confirming safety. Misoperation may lead to damage o
Résumé du contenu de la page N° 5
User's Manual Chapter 1: Outline Chapter 2: Handling Precautions Chapter 3: System Configuration Chapter 4: Name and Function of Each Part Chapter 5: Installation Chapter 6: Connection/Wiring Chapter 7: Use Guide Chapter 8: Cyclic Transfer Chapter 9: Message Transfers Chapter 10: Communication Control Chapter 11: SEND/RECEIVE Function Chapter 12: Parameters Chapter 13: Troubleshooting Chapter 14: Specifications Chapter 15: Appendix Alphabetical Index
Résumé du contenu de la page N° 6
Table of Contents Chapter 1: Outline ...................................................................................................... 1-1 Chapter 2: Handling Precautions ............................................................................. 2-1 Chapter 3: System Configuration ............................................................................. 3-1 Chapter 4: Name and Function of Each Part .................................................... 4-1 to 4 4-1 JW-20FL5 ...........
Résumé du contenu de la page N° 7
(1) Cyclic transfer .................................................................................................................... 7-10 (2) Message transfer ................................................................................................................7-11 [5] Transfer cycle ............................................................................................................................7-11 [6] Data area and memory ...............................................
Résumé du contenu de la page N° 8
(3) Execution condition ........................................................................................................... 9-21 (4) Table of commands ........................................................................................................... 9-22 [3] Descriptions of each command ................................................................................................ 9-23 [4] Computer link error code table ..........................................................
Résumé du contenu de la page N° 9
[1] General specifications .............................................................................................................. 14-3 [2] Communication specifications .................................................................................................. 14-3 [3] External dimension drawings ................................................................................................... 14-3 14-3 JW-50FL ......................................................................
Résumé du contenu de la page N° 10
[6] Status management of the FL-net .......................................................................................... 15-28 [7] Control message sequence number of the FL-net ................................................................. 15-28 15-5 Parts needed to build a network ............................................................................................. 15-29 [1] Parts needed to configure an Ethernet...................................................................