Resumen del contenido incluido en la página 1
To contact LG Electronics, 24 hours a day,
GAS COOKTOP
7 days a week:
1-800-243-0000 (U.S.A.)
1-888-542-2623 (Canada)
INSTALLATION INSTRUCTIONS
Or visit us on the Web at:
Please read this guide thoroughly
us.lge.com (U.S.A.)
before installation.
ca.lge.com (Canada)
BEFORE YOU BEGIN
Note to Installer: Leave these instructions with
Read these instructions completely
the appliance after installation is completed.
and carefully.
Note to Consumer: Keep the User’s Guide and
Ins
Resumen del contenido incluido en la página 2
INSTALLATION INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE INSTALLATION IN THE COMMONWEALTH OF MASSACHUSETTS • This product must be installed by a licensed • A flexible gas connector, when used, must not plumber or gas fitter. exceed 3 feet in length. • When using ball type gas shut-off valves, they shall be the T-handle type. FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS WARNING: If the information in this Do not try to light any appliance. • manual is not followed exactly, a fire or Do
Resumen del contenido incluido en la página 3
INSTALLATION INSTRUCTIONS INSTALLATION SAFETY INSTRUCTIONS BEFORE YOU BEGIN Remove all tape and packing materials before using the cooktop. Dispose all plastic bags after unpacking the cooktop. Never allow children to play with packing materials. IMPORTANT SAFETY INSTRUCTIONS Read these instructions completely and carefully. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualifi
Resumen del contenido incluido en la página 4
INSTALLATION INSTRUCTIONS INSTALLATION SAFETY INSTRUCTIONS (continued) • The ventilating hood must be constructed of sheet • The vertical distance from the plane of the cooking metal not less than 0.0122” thick. Install above the surface to the bottom of adjacent overhead cabinets cooktop with a clearance of not less than 1/4” extending closer than 1” to the plane of the cooktop between the hood and the underside of the sides must not be less than 18”. (See the combustible materia
Resumen del contenido incluido en la página 5
INSTALLATION INSTRUCTIONS DIMENSIONS AND CLEARANCES Provide enough clearances between the cooktop The cooktop may be placed with 2 3/4” clearance to and adjacent combustible surfaces. These dimensions the back wall. must be met for safe use of your cooktop. The location of the electrical outlet and pipe opening may be adjusted to meet specific requirements. 1. MAINTAIN THE FOLLOWING 3. RECOMMENDED GAS SUPPLY MINIMUM CLEARANCE LOCATION FROM BACKWALL DIMENSIONS 1” Min. From Backwall 1
Resumen del contenido incluido en la página 6
INSTALLATION INSTRUCTIONS INSTALLING THE COOKTOP UNIT 1. LOCATE ELECTRICAL OUTLET 4 INSTALL THE RETAINER BRACKETS AND GAS SHUT-OFF VALVE Install the retainer brackets to the bottom of the cooktop unit. then snug the bolts BENEATH CABINET against the bottom of the countertop as NEVER RE-USE shown OLD FLEX Electrical Shut-Off CONNECTORS. outlet 12˝ valve below countertop Install a manual shut-off valve in the gas line in an easily accessible location outside the Retainer brackets
Resumen del contenido incluido en la página 7
INSTALLATION INSTRUCTIONS 1. PROVIDE ADEQUATE GAS SUPPLY This cooktop is designed to operate at a pressure For LP gas, the pressure supplied must be between of 5” of water column on natural gas or 10” of water 10” and 13” of water column. column on LP, propan or butane gas. When checking for correct operation of the regulator, the inlet pressure must be at least 1” more than the Make sure you are supplying your cooktop with the operating -manifold- pressure as given above. type of gas for
Resumen del contenido incluido en la página 8
INSTALLATION INSTRUCTIONS FLEXIBLE CONNECTOR HOOKUP Pressure regulator Adapter Gas Flow into Range Flex connector (6 ft. max.) Adapter Installer: Inform the Gas consumer of the shut-off 1/2” or 3/4” location of the gas valve Gas pipe shut-off valve. 8
Resumen del contenido incluido en la página 9
INSTALLATION INSTRUCTIONS 3. ELECTRICAL CONNECTIONS ELECTRICAL REQUIREMENTS 120 Volt, 60 Hertz, properly grounded dedicated The power cord of this appliance should be equipped circuit protected by a 15 A or 20 A circuit with a three-prong (grounding) plug which mates with breaker or time delay fuse. a standard three-prong grounding wall receptacle to reduce the possibility of electric shock hazard from this appliance. GROUNDING The customer should have the wall receptacle and circuit chec
Resumen del contenido incluido en la página 10
INSTALLATION INSTRUCTIONS (continued) 3. ELECTRICAL CONNECTIONS The installation of appliances designed for mobile home installation should conform with the Manufactured C A UTION Home Construction and Safety Standard, Title 24 The customer should have the circuit checked by CFR, Part 3280 (formerly the Federal Standard for a qualified technician to make sure the receptacle Mobile Home Construction and Safety, Title 24, HUD, is correctly grounded. Part 280) or, when such standard is not applic
Resumen del contenido incluido en la página 11
INSTALLATION INSTRUCTIONS 5. ASSEMBLE THE SURFACE BURNERS Make sure the hole in the burner head is positioned over the electrode. CAUTION DO NOT operate the burners without all parts in place. H o l e Place the burner caps and heads on the cooktop. Make sure that the caps and heads are placed in the E l e c t r o d e correct locations. Extra large burner(Center) head and cap Small burner head and cap Medium burner head and cap Lrage burner head and cap 6. CHECK IGNITION OF SURFACE BURNERS Ope
Resumen del contenido incluido en la página 12
INSTALLATION INSTRUCTIONS 7. ADJUST THE SURFACE BURNER LOW FLAME (SIMMER) SETTING 7. Position center burner head, center burner cap, For all surface burners except for the center center grate, center knob. burner 8. Connect power to appliance. 1. Light all surface burners except for the center 9. Light center burner. burner. 10. Turn the knob on the burner being adjusted 2. Turn the knob on the burner being adjusted to to “LO”(LOW). “LO”(LOW). 11. Remove knob. 3. Remov
Resumen del contenido incluido en la página 13
INSTALLATION INSTRUCTIONS WHEN ALL HOOKUPS ARE COMPLETE Make sure all controls are left in the off position. Make sure the flow of combustion and ventilation air to the cooktop is unobstructed. CONVERTING TO LP GAS (OR CONVERTING BACK TO NATURAL GAS FROM LP) This cooktop leaves the factory set for use with The conversion instructions and LP orifices are natural gas. When converting to LP gas, the supplied with your cooktop. conversion must be performed by a qualified LP Keep these inst
Resumen del contenido incluido en la página 14
M e m o 14
Resumen del contenido incluido en la página 15
Printed In Korea Impreso en Korea Imprimé en Corée