Resumen del contenido incluido en la página 1
10GbE Pass-Thru Module
User Guide
Part Number 573130-002
December 2010 (Second Edition)
Resumen del contenido incluido en la página 2
© Copyright 2009, 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Microsoft and Windows are U.S. registered trademarks of Mic
Resumen del contenido incluido en la página 3
Contents Introduction .................................................................................................................................. 5 Features ................................................................................................................................................... 5 Enterprise class performance ............................................................................................................. 5 Configuration and management ..........
Resumen del contenido incluido en la página 4
Cannot connect to the pass-thru module console interface remotely using Onboard Administrator ...................... 22 The download fails after starting to download the firmware file ..................................................................... 23 The pass-thru module configuration is corrupt .............................................................................................. 23 SFP+ transceiver port is disabled ............................................................
Resumen del contenido incluido en la página 5
Introduction Features The 10GbE Pass-Thru Module is designed for easy installation and high performance in an environment where network traffic and users increase continually. Enterprise class performance The 10GbE Pass-Thru Module includes the following features: • The unique ability to provide both 1 Gigabit and 10 Gigabit functionality on each port, enabling greater network flexibility • Full support on the HP c-Class BladeSystem server blade enclosure and infrastructure compatibl
Resumen del contenido incluido en la página 6
Port mapping For detailed port mapping information, see the HP BladeSystem Enclosure Quick Setup Guide or the HP BladeSystem Enclosure Setup and Installation Guide on the HP website (http://www.hp.com/go/bladesystem/documentation). Dual pass-thru modules In a dual pass-thru module configuration, two pass-thru modules in the HP BladeSystem c7000 Enclosure provide redundant paths to the network ports on the server blades. Redundant paths to server bays In a dual pass-thru module conf
Resumen del contenido incluido en la página 7
Component identification 10GbE Pass-Thru Module front panel CAUTION: If you press the Reset button while the Health LED is green, the pass-thru module resets. Item Description 1 UID LED • Blue light on—The pass-thru module is activated. • Blue light off—The pass-thru module is deactivated. 2 Health LED • Off—The pass-thru module is powered off. • Green—The pass-thru module is powered up, and all ports match. • Amber—An issue exists, such as a port mismatch. For
Resumen del contenido incluido en la página 8
Item Description 4 Reset button 5 Mini-USB RS232 management serial port 6 Ports 1-16 SFP+ ports to support SFP and SFP+ transceiver modules and Direct Attach Cables (DAC). Component identification 8
Resumen del contenido incluido en la página 9
Installing the pass-thru module Manually configuring the pass-thru module Configure the pass-thru module manually using a CLI. See "Accessing the pass-thru module ("Accessing the pass-thru module CLI" on page 10)" for more information. Module security The 10GbE Pass-Thru Module does not provide network security. You must provide security for the module from somewhere else on the network. Installing the module CAUTION: Do not attach the pass-thru module cables until after config
Resumen del contenido incluido en la página 10
4. Close the handle (2). Complete installation is indicated by a green Health LED. If the Health LED is amber or power is not applied to the module, see the HP BladeSystem Enclosure Setup and Installation Guide for troubleshooting information. Accessing the pass-thru module CLI You can access the pass-thru module CLI remotely using the Onboard Administrator enclosure or locally using the mini-USB to DB-9 RS232 Management serial port. Accessing the pass-thru module CLI remotely 1.
Resumen del contenido incluido en la página 11
Accessing the pass-thru module CLI locally 1. Using a null-modem mini-USB to DB-9 RS232 serial cable (not included), connect the pass-thru module management port to a local client device (such as a laptop computer). 2. Open a terminal emulation session and set the following parameters: Parameter Value Baud rate 9600 Data bits 8 Parity None Stop bits 1 Flow control None Production mode CLI The CLI provides backward and forward cursor control, backward deletion capability, and a
Resumen del contenido incluido en la página 12
• The system/info command displays image version, board revision, or chip revisions. • The effect from any CLI command is immediate. For example, configuring auto-negotiation on a port takes effect when the command is completed. • Flow control is not configurable because the pass-thru module cannot handle or generate pause packets. When using the 10GbE Pass-Thru Module, you must ensure that your pause configuration is correct for both link partners. Installing SFP+ transceivers CA
Resumen del contenido incluido en la página 13
Replacing a pass-thru module Replacing an existing module CAUTION: Removing the pass-thru module from a powered enclosure results in the loss of network communications between the server blade network ports and the network infrastructure. For continued blade-server network communication and services availability before removing the module, redirect critical high-availability services or applications to use the redundant network ports. CAUTION: Do not connect the pass-thru
Resumen del contenido incluido en la página 14
Updating the 10GbE pass-thru firmware Methods for updating the 10GbE Pass-Thru Module firmware CAUTION: The pass-thru module automatically reboots after the firmware update, which disrupts all server traffic on all ports on this pass-thru module. The server blades can be powered on while this pass-thru module firmware is updated, but they lose connectivity while the firmware reboots on each pass-thru module. CAUTION: Do not power off the pass-thru module during the download
Resumen del contenido incluido en la página 15
NOTE: If you are using a USB key to transfer the firmware file, see "Updating the firmware image using a USB key and the Onboard Administrator CLI (on page 17)" for steps that must be completed before beginning this procedure. 1. Access the Onboard Administrator CLI remotely using Telnet or SSH, or locally using a serial connection to the active Onboard Administrator DB9 serial connector, or VGA and keyboard connected to the enclosure KVM ports. For more information on how to access
Resumen del contenido incluido en la página 16
12. Press the Enter key. The module console begins to print C characters until the Xmodem transfer begins. 13. Press Ctrl + Shift + _. The following message appears: Command: D)isconnect, C)hange settings, send B)reak, E)xit command mode X)modem send > 14. Enter x. The following message appears: Xmodem Send: Send a file to the interconnect module using the xmodem transfer protocol. The file can be downloaded to the OA from an HTTP(S), FTP, or TFTP server. After the file has been downlo
Resumen del contenido incluido en la página 17
Port 13 is ENABLED Port 14 is ENABLED Port 15 is ENABLED Port 16 is ENABLED Port 1 Installed CU SFP Port 1 Approved CU SFP NOTE: If the module console displays C characters instead of . characters, return to step 14 to restart the Xmodem transfer. 17. Press Ctrl + Shift + _. The following message appears: Command: D)isconnect, C)hange settings, send B)reak, E)xit command mode X)modem send > 18. Enter d. 19. To update the firmware on any other pass-thru modules installed in
Resumen del contenido incluido en la página 18
Secondary DNS: 16.110.135.52 MAC Address: F4:CE:46:86:FA:5D Link Settings: Auto-Negotiation, 100 Mbit, Full Duplex Link Status: Active Enclosure IP Mode: Disabled 8. To begin the firmware upgrade, begin at step 3 of "Updating the firmware image using the Onboard Administrator CLI (on page 14)" and continue following the instructions. The pass-thru module firmware is available as a URL (http://OA_IP_Address/media/usbkey/d1/filename) at the active
Resumen del contenido incluido en la página 19
NOTE: The pass-thru module boot code firmware image is usually named 10GPTHRU- w.x.y.z_FW.bin, where w.x.y.z is the firmware version number. 1. Using the null modem mini-USB to DB-9 cable, connect the console port of the pass-thru module to the serial port of a computer that supports XModem/1K XModem. 2. Start HyperTerminal (part of Microsoft® Windows® operating system) or equivalent terminal emulation application (depending on the operating system), and set the parameters for termina
Resumen del contenido incluido en la página 20
For more information Additional references Configure the 10GbE Pass-Thru Module after installation. Detailed information about how to configure the pass-thru module is available in 10GbE Pass-Thru Module Installation Instructions for HP BladeSystem c- Class Enclosures. For more information 20