Resumen del contenido incluido en la página 1
REJ10B0197-0100
H8S/2635 FP-128
User System Interface Cable
HS2635ECH61H User’s Manual
Renesas Microcomputer Development Environment System
H8S Family / H8S/2600 Series
HS2635ECH61HE
Rev.1.00
Revision Date: Jun. 10, 2005
Resumen del contenido incluido en la página 2
Resumen del contenido incluido en la página 3
Keep safety first in your circuit designs! 1. Renesas Technology Corp. puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal injury, fire or property damage. Remember to give due consideration to safety when making your circuit designs, with appropriate measures such as (i) placement of substitutive, auxiliary circuits, (ii) use of nonflammabl
Resumen del contenido incluido en la página 4
Resumen del contenido incluido en la página 5
IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user system interface cable. KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. User System Interface Cable: Throughout this document, the term "user system interface cable" shall be defined as the following product produced only by Renesas Technology Corp. excluding all subsidiary products. • User system interface cable (H
Resumen del contenido incluido en la página 6
LIMITED WARRANTY Renesas warrants its user system interface cables to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Renesas will repair or replace any user system interface cables determined to be defective in material and/or workmanship. User system interface cables are wearing parts which Renesas will not repair or replace if damaged and/or worn through use. The foregoing shall constitute the sole remedy for any breach of
Resumen del contenido incluido en la página 7
State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may have other rights which may vary from state to state. The Warranty is Void in the Following Cases: Renesas shall have no liability or legal responsibility for any problems caused by misuse, abuse, misapplication, neglect, improper h
Resumen del contenido incluido en la página 8
SAFETY PAGE READ FIRST READ this user's manual before using this user system interface cable. KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL WORDS This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER DANGER indicates an imminently hazardous
Resumen del contenido incluido en la página 9
WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance. 2. Always switch OFF the E6000 emulator and user system before connecting or disconnecting any CABLES or PARTS. 3. Always before connecting any CABLES, make sure that
Resumen del contenido incluido en la página 10
Preface Thank you for purchasing this user system interface cable (HS2635ECH61H) for the Renesas’ original microcomputer H8S/2635 group. The HS2635ECH61H is a user system interface cable that connects an H8S/2635, H8S/2636, and H8S/2646 group E6000 emulator (HS2646EPI61H; hereinafter referred to as the emulator) to the IC socket for an FP-128 package for the H8S/2635 group MCU on the user system. i
Resumen del contenido incluido en la página 11
Contents Section 1 Configuration....................................................................................1 Section 2 Connection Procedures ......................................................................4 2.1 Connecting User System Interface Cable to Emulator Station .........................................4 2.2 Connecting User System Interface Cable to User System ................................................6 2.2.1 Installing IC Socket.................................
Resumen del contenido incluido en la página 12
Section 1 Configuration CAUTION Use an NQPACK128RD socket (manufactured by Tokyo Eletech Corporation) for the FP-128 package IC socket on the user system. Figure 1 shows the configuration of the HS2635ECH61H user system interface cable for the FP- 128 package. 1
Resumen del contenido incluido en la página 13
Figure 1 HS2635ECH61H User System Interface Cable 2
Resumen del contenido incluido en la página 14
Table 1 lists the HS2635ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS2635ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Flat cable 2 Cable head 1 3 IC socket 1 For the FP-128 package 4 Socket cover 1 For installing an FP-128 packaged MCU 5 Screws (M2 × 10 mm) 4 For fastening cable head 6 Screws (M2 × 6 mm) 4 For installing an FP-128 packaged MCU 7 Guide pins 3 For determining the IC socket location 8 Screwdriver 1 For tightening
Resumen del contenido incluido en la página 15
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on
Resumen del contenido incluido en la página 16
Figure 2 Connecting User System Interface Cable to Emulator Station 5
Resumen del contenido incluido en la página 17
2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect the cable head to the user sy
Resumen del contenido incluido en la página 18
Guide pins Pin 1 4 projections to apply epoxy resin adhesive to Bottom view of IC soket User system Figure 3 Location Setting of IC Socket 2.2.2 Soldering IC Socket After fastening, solder the IC socket for an FP-128 package to the user system. Be sure to completely solder the leads so that the solder slops gently over the leads and forms solder fillets. (Use slightly more solder than the MCU.) 2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on th
Resumen del contenido incluido en la página 19
2.2.4 Fastening Cable Head CAUTION 1. Use the screwdriber provided for tightening screws. 2. The tightening torque must be 0.054 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder. 3. If the emulator does not operate
Resumen del contenido incluido en la página 20
Figure 4 Connecting User System Interface Cable to User System 9