Resumen del contenido incluido en la página 2
Cautions 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Renesas bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document. 2. Products and product specifications may be subject to change without notice.
Resumen del contenido incluido en la página 3
Preface Thank you for purchasing this user system interface cable (HS2128ECH61H) for the Renesas’s original microcomputer H8S/2128 series. The HS2128ECH61H is a user system interface cable that connects an H8S/2148, H8S/2138, H8S/2128 series E6000 emulator (HS2148EPI61H; hereinafter referred to as the emulator) to the IC socket for a QFP-64A package (package code: FP-64A) for the H8S/2128 series MCU on the user system. i
Resumen del contenido incluido en la página 4
Contents Section 1 Configuration....................................................................................................1 Section 2 Connection Procedures ...................................................................................4 2.1 Connecting User System Interface Cable to Emulator Station .........................................4 2.2 Connecting User System Interface Cable to User System ................................................5 2.2.1 Installing IC Soc
Resumen del contenido incluido en la página 5
Section 1 Configuration CAUTION Use an IC149-064-008-B5 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-64A package IC socket on the user system. Figure 1 shows the configuration of the HS2128ECH61H user system interface cable for the FP-64A package. 1
Resumen del contenido incluido en la página 6
Screws (M2.0 x 12 mm) and flat washers Screws (M2.0 x 8 mm) (For fastening cable and flat washers head) Socket cover Cable head IC socket User system Figure 1 HS2128ECH61H User System Interface Cable 2
Resumen del contenido incluido en la página 7
Table 1 lists the HS2128ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS2128ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Includes flat cable 2 Cable head 1 3 IC socket 1 For the FP-64A package 4 Socket cover 1 For installing an FP-64A packaged MCU 5 Screws (M2 x 12 mm) 4 For fastening cable head (with four flat washers) 6 Screws (M2 x 8 mm) 4 For installing an FP-64A packaged MCU (with four flat washers) 7 Documentati
Resumen del contenido incluido en la página 8
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect t
Resumen del contenido incluido en la página 9
2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect the cable head to the user system, follow
Resumen del contenido incluido en la página 10
2.2.4 Fastening Cable Head CAUTION 1. Use a Phillips-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.0785 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may break or an IC socket contact error may be caused by a crack in the IC so
Resumen del contenido incluido en la página 11
Screws (M2.0 x 12 mm) and flat washers Cable head Pin 1 IC socket (IC149-064-008-B5 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Figure 3 Connecting User System Interface Cable to User System 7
Resumen del contenido incluido en la página 12
2.2.5 Connecting Cable Body to Cable Head Connect the cable body to the cable head. Cable body Removing Push the remove jig Remove jig Cable head User system Figure 4 Fastening Cable Body 8
Resumen del contenido incluido en la página 13
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-64A package (IC149-064-008-B5: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those of the actual chip's mount pad. 20.80 (min.) 14.80 (max.) 0.8 x 15 = 12.00 – 0.1 + 0.1 0.45 0.80 – 0.05 - 0.05 Unit: mm Figure 5 Recommended Dimensions for Mount Pa
Resumen del contenido incluido en la página 14
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Unit: mm Tolerance: –0.5 mm Figure 6 Dimensions for User System Interface Cable Head 10
Resumen del contenido incluido en la página 15
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. Unit: mm IC socket Tolerance: ± 0.5 mm (IC149-064-008-B5 User system manufactured by YAMAICHI ELECTRONICS Co., Ltd.) Figure 7 Resulting Dimensions after Connecting User System Interface Cable 11 9.4
Resumen del contenido incluido en la página 16
Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Phillips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.0785 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may bre
Resumen del contenido incluido en la página 17
Socket cover MCU Pin 1 mark IC socket (IC149-064-008-B5 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Figure 8 Installing MCU to User System 13
Resumen del contenido incluido en la página 18
Section 4 Verifying Operation 1. When using the E6000 emulator (HS2148EPI61H) for the H8S/2148, H8S/2138, H8S/2128 series, turn on the emulator according to the procedures described in the H8S Series E6000 Emulator User's Manual (HS2000EPI61HE). 2. Verify the user system interface cable connections by accessing the external memory and ports to check the bus states of the pins with the MEMORY_FILL command (emulator command). If an error is detected, recheck the soldered IC socket and the
Resumen del contenido incluido en la página 19
Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU. 3. This user system interface cable is specifically designed for the HS2148EPI61H emulator. Do not use this cable with any other emulator station. 4. To prevent breaking of wires in the ca