Resumen del contenido incluido en la página 1
HARDWARE MANUAL
F940GOT-SWD-E/LWD-E
Resumen del contenido incluido en la página 2
F940GOT-SWD-E/LWD-E Foreword • This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the communication facilities of FX series. • Before attempting to install or use the communication facilities of FX series this manual should be read and understood. • If in doubt at any stage of the installation of the communication facilities of FX series always consult a professional electrical engineer who is qualified and trained to the
Resumen del contenido incluido en la página 3
F940GOT-SWD-E/LWD-E F940GOT-SWD-E/LWD-E Manual number : JY992D77901 HARDWARE MANUAL Manual revision : D Date : February 2000 i
Resumen del contenido incluido en la página 4
F940GOT-SWD-E/LWD-E Guidelines for the safety of the user and protection of the F940GOT-SWD-E/LWD-E This manual provides information for the installation and use of the Graphic Operation Terminal F940GOT. The manual has been written to be used by trained and competent personnel. The definition of such a person or persons is as follows; a ) Any engineer who is responsible for the planning, design and construction of automatic equipment using the product associated with this manual should be of a
Resumen del contenido incluido en la página 5
F940GOT-SWD-E/LWD-E Note’s on the symbology used in this manual At various times through out this manual certain symbols will be used to highlight points of information which are intended to ensure the users personal safety and protect the integrity of the equipment. Whenever any of the following symbols are encountered, its associated note must be read and understood. Each of the sym- bols used will now be listed with a brief description of its meaning. Hardware warnings 1 ) Indicates that the
Resumen del contenido incluido en la página 6
F940GOT-SWD-E/LWD-E Memo iv
Resumen del contenido incluido en la página 7
F940GOT-SWD-E/LWD-E CONTENTS 1. INTRODUCTION...................................................................................1-1 1.1 Outline of product ................................................................................................1-2 1.2 Product configuration........................................................................................... 1-8 1.3 System configuration ......................................................................................... 1-14 2. In
Resumen del contenido incluido en la página 8
F940GOT-SWD-E/LWD-E 5. Maintenance..........................................................................................5-1 5.1 Outline of maintenance........................................................................................5-1 5.2 Replacement of battery .......................................................................................5-3 5.3 Replacement of backlight .................................................................................... 5-5 6. Troubleshooting
Resumen del contenido incluido en la página 9
F940GOT-SWD-E/LWD-E INTRODUCTION 1. 1. INTRODUCTION This section describes the product configuration and the system configuration of the graphic operation terminal. Confirm various functions of each unit. 1-1
Resumen del contenido incluido en la página 10
F940GOT-SWD-E/LWD-E INTRODUCTION 1. 1.1 Outline of product The graphic operation terminal (which may be hereafter FX or A Series PLC abbreviated as "GOT") is attached on the panel face of a control panel or an operation panel, and connected to a program connector in an FX or A Series programmable controller (which may be hereafter abbreviated as "PLC") Program (except the A0J2) inside the control panel. connector Not only the CPU port connection method but also the computer link port connection
Resumen del contenido incluido en la página 11
F940GOT-SWD-E/LWD-E INTRODUCTION 1. User screens 1) Screen display function The screens created by the user can be displayed. The following functions can be assigned to each screen. And the screens to be displayed can be limited using the security function. a) Display function -Up to 500 screens created by the user can be displayed. The screens can be created using the FX-PCS-DU/WIN-E V2.00 for the DU or using the SWoD5C-GOTRE-PACK ("o" indicates a numeric not less than 1.) for the GOT. Two
Resumen del contenido incluido en la página 12
F940GOT-SWD-E/LWD-E INTRODUCTION 1. c) Data change function -The numeric data being monitored can be changed. d) Switch function -By manipulating the operation keys in the GOT, bit devices in the PLC can be set to ON and OFF. The display panel face can be assigned as touch keys to offer the switch func- tion. Make sure to press a touch key by fingers. If a touch key is pressed by a hard or sharp object, it may become failed. 1-4
Resumen del contenido incluido en la página 13
F940GOT-SWD-E/LWD-E INTRODUCTION 1. System screens 1) Monitor function a) List program (only in the FX Series) - Programs can be read, written and monitored in the form of instruction list program. b) Buffer memory (only in the FX2N and FX2NC Series) -The contents of buffer memories (BFMs) of special blocks can be read, written and monitored. c) Device monitor -The ON/OFF status of each device and the set value and the current value of each timer, counter and data register in the PLC can be moni
Resumen del contenido incluido en la página 14
F940GOT-SWD-E/LWD-E INTRODUCTION 1. d) Data sampling function The current value of specified data registers are acquired in a constant cycle or when the trigger condition is satisfied. -The sampling data can be displayed in the form of list or graph. -The sampling data can be output to a printer in the form of list. e) Alarm function Alarm messages can be assigned to up to 256 consecutive bit devices in the PLC. When a bit device becomes ON, the assigned message is displayed (overlapped) on
Resumen del contenido incluido en la página 15
F940GOT-SWD-E/LWD-E INTRODUCTION 1. f) Other functions Many other functions are built in. -The real-time clock is built in, and the current time can be set and displayed. -The GOT can function as an interface to enable data communication between the PLC and a personal computer in which the relay ladder creation software is started up. At this time, the GOT screen can be displayed also. -The screen contrast and the buzzer sound volume can be adjusted. 1-7
Resumen del contenido incluido en la página 16
F940GOT-SWD-E/LWD-E INTRODUCTION 1. 1.2 Product configuration The GOT is equipped with accessories (1) to (3) below. Parts (4) to (8) are offered as options. 1) F940GOT (main body) F940GOT-SWD-E: 5.7" STN type LCD (with eight colors) F940GOT-LWD-E: 5.7" STN type LCD (with black and white) 2) Metal fixtures Metal fixtures used to attach the GOT to a control panel - Metal fixture 6 pieces - Tightening bolt 6 pieces (M3 x 20) 1-8
Resumen del contenido incluido en la página 17
F940GOT-SWD-E/LWD-E INTRODUCTION 1. 3) Packing Packing to prevent dusts and water Used to attach the GOT to a control panel 1-9
Resumen del contenido incluido en la página 18
F940GOT-SWD-E/LWD-E INTRODUCTION 1. Optional parts 4) Software to create user screens (3.5" FD) FX-PCS-DU/WIN-E V2.10 or later (in accordance with the Windows95) SWoD5C-GOTRE-PACK ("o" indicates a numeric not less than 1.) (in accordance with the Windows95 and the WindowsNT) 5) Connection cable FX-40DU-CAB (3 m, 9.84 ft) Connection cable FX-40DU-CAB-10M (10 m, 32.81 ft) Connection cable FX-50DU-CABL (3m, 9.84 ft, with L-shape connector on the GOT side) Each of them is an optional cable to co
Resumen del contenido incluido en la página 19
F940GOT-SWD-E/LWD-E INTRODUCTION 1. 6) Connection cable FX-50DU-CAB0 (3 m, 9.84 ft) Connection cable FX-50DU-CAB0-1M (1 m, 3.28 ft) Connection cable FX-50DU-CAB0-10M (10 m, 32.81 ft) Connection cable FX-50DU-CAB0-20M (20 m, 65.62 ft) Connection cable FX-50DU-CAB0-30M (30 m, 98.43 ft) Connection cable FX-50DU-CAB0L (3 m, 9.84 ft, with L-shape connector on the GOT side) Each of them is an optional cable to connect the GOT and 0 0S 0N 2N 2NC the FX /FX /FX /FX /FX Series PLC. By using either one,
Resumen del contenido incluido en la página 20
F940GOT-SWD-E/LWD-E INTRODUCTION 1. 8) Battery PM-20BL (spare part) This is used to back up the alarm history data, the real-time clock, etc. This is attached when the GOT is delivered. 9) EPROM memory to store the user screen data FX-EPROM- 4M This is an optional EPROM memory (M27C4002-**F (4 MB) manufactured by SGS-THOMSON) to save the user screen data. The user screen data can be written using a general-pur- pose ROM writer connected to the screen creation soft- ware. 1-12