Resumen del contenido incluido en la página 1
VR-6000 VR-6000
OWNER©S MANUAL
MANUEL D©INSTRUCTIONS
MANUAL DE INSTRUCCIONES
VER 5 JAN 2005
842-410-000
Resumen del contenido incluido en la página 2
INSTRUCTIONS MANUAL
Resumen del contenido incluido en la página 3
INSTRUCTIONS MANUAL INDEX INDEX.............................................................................................................................................................................................................3 SAFETYSUMMARY............................................................................................................................................................................4 SAFETYINFORMATION..........................................................
Resumen del contenido incluido en la página 4
INSTRUCTIONS MANUAL RECOVERINGTHEREFRIGERANTINTHEHOSES...................................................................................19 MAINTENANCE..................................................................................................................................................................................20 REPLACING REFRIGERANTFILTER/DRYER...................................................................................................20 EMPTYING THEUSED OILTANK.........
Resumen del contenido incluido en la página 5
INSTRUCTIONS MANUAL READ ALL SAFETY INFORMATION CAREFULLY before attempting to install, operate or service this equipment. Failure to complywith these instructions could result in personal injuryand/orpropertydamage. RETAINTHEFOLLOWINGSAFETYINFORMATIONFORFUTUREREFERENCE. Publishedstandards onsafetyareavailable.TheyarelistedinADDITIONALSAFETY INFORMATIONattheendofthis SAFETYSUMMARY. TheNationalElectricalCode,OccupationalSafetyandHealthActregulations, local industrial codes andlocal inspection req
Resumen del contenido incluido en la página 6
INSTRUCTIONS MANUAL anyone else that uses this equipment, understands and follows these safety instructions aswell. • Avoid breathing AC refrigerant and lubricant vapor mist. Exposure may irritate eyes, nose, andthroat.ToremoveHFC-134a from the AC system, use service equipment certifiedtomeettherequirements ofSAEJ2210(HFC-134arecyclingequipment). • Additional health and safetyinformation maybe obtained from additional refrigerant andlubricantmanufacturers. • Always perform vehicle service in a p
Resumen del contenido incluido en la página 7
INSTRUCTIONS MANUAL INTRODUCTION GENERAL Thankyouforpurchasinga VIPER VR-6000AirConditioning ServiceCenter.Your VR-6000 isUnderwriters Laboratories Inc.®approved,incompliancewithSAEJ 2210 (1991).Weare dedicatedtosolvingtheissuessurroundingthesafe containmentandpropermanagement ofCFC’S.YournewVR-6000incorporates thelatesttechnologyandstate oftheartfeatures toaidyouinservicingairconditioning andrefrigeration systems. Wehope yougetas much enjoymentusingthis equipmentaswediddesigningandbuildingit. C
Resumen del contenido incluido en la página 8
INSTRUCTIONS MANUAL THEMACHINE BASICCOMPONENTS Refertofig1,2,3&4: a) ControlConsole b) Valves c) Handle d) High/LowPressureThreadedConnectors e) NewOilContainer f) StorageTank g) DesiccantFilters h) ElectronicScale i) HeaterBlanket j) MainPowerSwitch k) SocketforElectricalSupplyPlug l) Fuse m)UsedOilContainer n) SerialPort o) MoistureIndicator p) VacuumPump q) Wheels r) AirPurgeValve 8
Resumen del contenido incluido en la página 9
9
Resumen del contenido incluido en la página 10
INSTRUCTIONS MANUAL CONTROLSANDCONTROLSYSTEM RefertoFig5: (A1)LowpressuregaugeforA/Csystem (A2)HighpressuregaugeforA/Csystem (A4)Pressuregaugeforstoragetank (A6)Emergency/alarms panel (A7)Display (A8) Keypadcontrols (A9)Operationsselectorpanel A4 A2 A6 A7 A8 A1 A9 Fig.5:ControlPanel 10
Resumen del contenido incluido en la página 11
INSTRUCTIONS MANUAL FUNCTIONSELECTORKEYBOARD RefertoFig6: (T1)REFRIGERANTAVAILABLELEDindicator:whenlit, thedisplayreports theweightofthe availablerefrigerantinthestoragetank. (T2)RECHARGELEDindicator(flashes duringtheCHARGINGphase). (T3)RECOVERYLEDindicator(flashes duringtheRECOVERYphase). (T4)EVACUATELEDindicator(flashes duringtheVACUUMphase). (T5)HOLD:flashesattheendoftherecoveryduringtheOILDISCHARGEphase. (T6) SELkey: Selects theoperation tobeperformed.Everytime this keyis pressed one of theL
Resumen del contenido incluido en la página 12
INSTRUCTIONS MANUAL orFahrenheitdegree. (T13) Display: According to the operation selected, displays the evacuation time, tank temperature,orweightofavailablerefrigerant. STATUSANDALARMPANEL SeeFig7: (C1) REPLACEFILTER:theLowside refrigerantfilter/dryer must bechangedwhen the led “REPLACEFILTER”lightsup.When recoveringnewrefrigerantthis light maycome on prematurely.ItmayberesetbypressingtheSELkeywhileturningonthemachine. (C2)HIGHPRESSURE:Lightsandemits anacoustic signalwhen thepressure oftheflui
Resumen del contenido incluido en la página 13
INSTRUCTIONS MANUAL MEASUREMENTSETTING WhenpoweristurnedontoyournewVIPER VR-6000, thekeypaddisplaywill show thegas weight in the service tank. The display can be set to read in either metric or standard measurements,proceedasfollows: • SwitchofftheVR-6000. • Press theSEL, GO,andENTER keys simultaneouslywhile turning on the VR-6000. Themachinewillchangefrom onesystemofunits ofmeasurementtotheother. VIPERVR-6000SPECIFICATIONS ElectricalInput: 115Vac,8 A,60Hz AmbientOperatingTemperatureRange: 50°F(
Resumen del contenido incluido en la página 14
14
Resumen del contenido incluido en la página 15
15
Resumen del contenido incluido en la página 16
INSTRUCTIONS MANUAL OPERATIONINSTRUCTIONS RECOVERANDRECYCLEREFRIGERANTFROM ANACSYSTEM 1. BesurethattheshutoffvalvesareoffpriortoattachingtoavehicleACsystem. 2. Attachthemachinetothehigh andlowsides oftheACsystem tobeserviced. TheR- 134a hoses have SAE approved shut-off valves (quick disconnects). The hoses are shut offwhen disconnected from theACsystem and are open only when connected withtheknurledknobs turnedclockwise.Slidethecollarofthefittingback andpress to theappropriatefitting. • Bluehose
Resumen del contenido incluido en la página 17
INSTRUCTIONS MANUAL Proceedasfollows: “REFRIGERANT AVAILABLE”LEDmust light,ifitis necessarypress theSELkeyto switch thelightto“REFRIGERANTAVAILABLE”LED. 1. Press once the “°F” key in order to display the refrigerant tank temperature (in Fahrenheit degree), press it a second time to display the temperature in Celsius degree) 2. Readthestoragetankpressureofthetankgauge 3. Find the temperature in the TEMP °F column for that tank then read the associated PRESSURE column inpsig. 4. IftherelatedTANK P
Resumen del contenido incluido en la página 18
INSTRUCTIONS MANUAL VACUUMPHASE 1. UponcompletionoftheRECOVERYphaseitis possible tostart thevacuum phase by opening the high- and low-pressure valves, pressing the SEL key until the LED correspondingto“EVACUATE”lights,andthen pressing GO.Thevacuum time canbe setasfollows.Press SELuntilthe“EVACUATE”LEDlights,then press ENTER;atthis pointthefirstdigitontheleftofthedisplaywillbegin toflash.Press theINCREASE key until thedesireddigit appears. Likewise, press the ARROW and INCREASE keys to changetheo
Resumen del contenido incluido en la página 19
INSTRUCTIONS MANUAL 3. Openthehigh-andlow-pressurevalves(ifpreviouslyclosed)andpress theGOkey. 4. Themachinewillstopautomaticallywhen thepresetquantityhas been charged. Ifthe A/C system pressure increases to equal the tank pressure, and the charge is not complete,itwill benecessarytodraw theremaining refrigerantinto thesystem using thevehiclecompressorasoutlinedbelow. 5. Closethehigh-andlow-pressurevalves. 6. StartthevehiclemotorandswitchontheA/Csystem,andallowbothtorunforatleast3 minutes.Atthis
Resumen del contenido incluido en la página 20
INSTRUCTIONS MANUAL MAINTENANCE REPLACING REFRIGERANTFILTER/DRYER TheVIPER VR-6000is equipped with twohigh side refrigerantfilters/dryers anda lowside refrigerantfilter/dryer(seefigure14).Inordertomaintainhighqualityrecycledrefrigerant: • Thelowside refrigerantfilter/dryer must bechanged when the VR-6000 displays the servicealarm [SERV]andtheled“REPLACEFILTER”lightsup. NOTE:Whenrecoveringnewrefrigerantaswhen themachineis first placedinservice this alarm will light abnormallyearly and maybe clear