Resumen del contenido incluido en la página 1
TWO SPEED
FLOOR AIR FILTER
MODEL G0573
INSTRUCTION MANUAL
COPYRIGHT © DECEMBER, 2004 BY GRIZZLY INDUSTRIAL, INC.
WARNING: NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE
OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL, INC.
#BL6811 PRINTED IN CHINA
Resumen del contenido incluido en la página 2
WARNING Some dust created by power sanding, sawing, grind- ing, drilling, and other construction activities contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. Some examples of these chemicals are: • Lead from lead-based paints. • Crystalline silica from bricks, cement, and other masonry products. • Arsenic and chromium from chemically treated lumber. Your risk from these exposures varies, depending on how often yo
Resumen del contenido incluido en la página 3
Table of Contents INTRODUCTION ............................................................................................................................... 2 Foreword .... 2 Contact Info 2 SECTION 1: SAFETY ....................................................................................................................... 3 Safety Instructions for Machinery ............................................................................................... 3 SECTION 2: CIRCUIT REQUIREMENTS ...
Resumen del contenido incluido en la página 4
INTRODUCTION Foreword Contact Info We are proud to offer the Model G0573 Two Speed If you have any comments regarding this manual, Floor Air Filter. This machine is part of a growing please write to us at the address below: Grizzly family of fine woodworking machinery. When used according to the guidelines set forth in Grizzly Industrial, Inc. C this manual, you can expect years of trouble-free, /O Technical Documentation enjoyable operation and proof of Grizzly’s com- P.O. Box 2069 mitmen
Resumen del contenido incluido en la página 5
SECTION 1: SAFETY For Your Own Safety, Read Instruction Manual Before Operating this Machine The purpose of safety symbols is to attract your attention to possible hazardous conditions. This manual uses a series of symbols and signal words which are intended to convey the level of importance of the safety messages. The progression of symbols is described below. Remember that safety messages by themselves do not eliminate danger and are not a substitute for proper accident prevention measure
Resumen del contenido incluido en la página 6
Safety Instructions for Machinery 7. ONLY ALLOW TRAINED AND PROP- 16. MAKE SURE GUARDS ARE IN PLACE ERLY SUPERVISED PERSONNEL TO AND WORK CORRECTLY BEFORE OPERATE MACHINERY. Make sure USING MACHINERY. operation instructions are safe and clearly understood. 17. REMOVE ADJUSTING KEYS AND WRENCHES. Make a habit of checking for 8. KEEP CHILDREN AND VISITORS AWAY. keys and adjusting wrenches before turn- Keep all children and visitors a safe dis- ing machinery ON. tance from the work area. 18
Resumen del contenido incluido en la página 7
Additional Safety for Air Filters 1. FILTER USE. This filter unit is only designed 6. MACHINE OPERATION. Always operate to remove very fine wood particles from the machine with the filter in place. When the air. DO NOT use this machine to filter the primary filter is removed, the impeller is or collect liquids (especially flammables), exposed to the unfiltered opening. metal shavings, lead paint, or asbestos. DO NOT use this machine to dissipate smoke, 7. FILTER CLEANING AND REPLACEMEN
Resumen del contenido incluido en la página 8
SECTION 2: CIRCUIT REQUIREMENTS 110V Operation Electrocution or fire could result if this machine is not grounded correctly or if your electrical configu- Serious personal injury could occur if you ration does not comply connect the machine to the power source with local and state codes. before you have completed the set up pro- Ensure compliance by cess. DO NOT connect the machine to the checking with a qualified power source until instructed to do so. electrician! Amperage Draw 3 The
Resumen del contenido incluido en la página 9
SECTION 3: SET UP Set Up Safety Items Needed For Set Up The following items are needed to complete the This machine presents set up process, but are not included with your serious injury hazards machine: to untrained users. Read through this entire manu- DESCRIPTION QTY al to become familiar with • 16 guage extension cord (50 feet or less) . 1 the controls and opera- • 12" diameter ducting (optional) .................. 1 tions before starting the machine! Simply attach the female end of
Resumen del contenido incluido en la página 10
Outlets Shop Preparation Make sure the electrical circuits have the capacity to handle the amperage requirements of the new air cleaner unit. Refer to Page 6 for more infor- mation. Electrical outlets should be located near the unit so power or extension cords are clear of DO NOT operate this air high-traffic areas. cleaner unit at a location where flammable fuels, solvents, or other vola- tile chemicals may exist. Since these products Site Planning have a low flash point, the fan mot
Resumen del contenido incluido en la página 11
Figure 2 shows an example of poor air circulation, Filter Capacity where the air filter is placed too close to obstruc- tions and the velocity of the air is lost and circula- tion is diminished. The G0573 Two Speed Floor Air Filter is designed to recirculate the entire volume of air in a 30' x 40' x 8' room approximately 12 times in one hour. For the best filtering effect, the volume in a room should be recirculated at least 6-8 times every hour. To calculate the recirculating rate for a
Resumen del contenido incluido en la página 12
SECTION 4: OPERATIONS Operation Safety Operations To operate the unit: 1. Connect the unit to power and push the HI Operating this equipment creates the poten- or LOW start switch. The fan should start up tial for flying debris to cause eye injury. and begin filtering air in the room. Always wear safety glasses when operating equipment. Everyday glasses or reading 2. If it does not start, turn the switch OFF and glasses only have impact resistant lenses, disconnect the power. they are n
Resumen del contenido incluido en la página 13
SECTION 5: MAINTENANCE Note—The pre-filter can be washed with water to remove the last of the dust and help maximize its filtering effect. DO NOT use To avoid personal injury, compressed air to clean the pre-filter, as it ! disconnect power to air may get damaged and lose its filtering capa- filter when performing bilities. any adjustments, clean- ing or maintenance. 4. Be sure the pre-filter is completely dry before re-installing it into the air filter. Use a respirator when The pr
Resumen del contenido incluido en la página 14
G0573 Wire Diagram ������������������ � � � -12- G0573 Two Speed Floor Air Filter
Resumen del contenido incluido en la página 15
G0573 Parts Breakdown -13- G0573 Two Speed Floor Air Filter 39 1 2 3 4 5 6 7 8 9 38 36 37 40 41 24 23 22 21 33 32 20 19 10 18 12 17 34 31 16 25 30 26 13 14 15 29 35 27 28
Resumen del contenido incluido en la página 16
G0573 Parts List REF PART # DESCRIPTION REF PART # DESCRIPTION 1 P0573001 BODY 22 PS21M PHLP HD SCR M4-.7 X 15 2 P0573002 STEELY GRATE 23 PHTEK5M TAP SCREW M4.2 X 12 3 P0573003 ANGLE IRON 24 P0573024 FUSE 4 P0573004 FAN PLATE 25 P0573025 SWITCH BOX 5 P0573005 FAN HOUSING 26 P0573026 SWITCH PLATE 6 P0573006 FAN BLADE 27 P0573027 STRAIN RELIEF M20 X 1.5 7 P0573007 PRIMARY FILTER 28 P0573028 POWER CORD W/ PLUG 8 P0573008 PRE-FILTER 29 PN02M HEX NUT M10-1.5 9 P0573009 INLET AIR DOOR 30 P0573030 SWIT
Resumen del contenido incluido en la página 17
Troubleshooting Symptom Possible Cause Possible Solution 1. The power supply circuit breaker is 1. Correct the cause for high current draw The air cleaner does not operate at all. tripped. and close the circuit breaker. 2. No power to the control panel 2. Replace the blown fuse in the control 3. Wiring is at fault panel. 4. The control panel circuit board is at 3. Repair, replace wires, plugs and cables fault. as applicable; and make sure all electri- 5. The motor is at fault. cal plugs an
Resumen del contenido incluido en la página 18
WARRANTY AND RETURNS Grizzly Industrial, Inc. warrants every product it sells for a period of 1 year to the original purchaser from the date of purchase. This warranty does not apply to defects due directly or indirectly to misuse, abuse, negligence, accidents, repairs or alterations or lack of maintenance. This is Grizzly’s sole written warranty and any and all warranties that may be implied by law, including any merchantability or fitness, for any par- ticular purpose, are hereby limited t
Resumen del contenido incluido en la página 19
WARRANTY CARD Name _____________________________________________________________________________ Street _____________________________________________________________________________ City _______________________ State _________________________ Zip _____________________ Phone # ____________________ Email ________________________ Invoice # _________________ Model # ____________________ Order # _______________________ Serial # __________________ The following information is given on a voluntary bas
Resumen del contenido incluido en la página 20
FOLD ALONG DOTTED LINE Place Stamp Here GRIZZLY INDUSTRIAL, INC. P.O. BOX 2069 BELLINGHAM, WA 98227-2069 FOLD ALONG DOTTED LINE Send a Grizzly Catalog to a friend: Name_______________________________ Street_______________________________ City______________State______Zip______ TAPE ALONG EDGES--PLEASE DO NOT STAPLE