Resumen del contenido incluido en la página 1
Model Number:
SG-CAC-08ESE
Electronic Casement Window Air Conditioner
Operating Instructions
Resumen del contenido incluido en la página 2
Thank you for choosing a Soleus Air powered by Gree Air Conditioner. This owner’s manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new air conditioner. For your own records, please attach a copy of your sales receipt to this manual. Also, write the store name/location, date purchased, and seria
Resumen del contenido incluido en la página 3
SPECIFICATIONS • Noise level is measured at a distance of 3.28 ft away from the front of the unit in cooling mode. • Power consumption is measured when the fan runs at the highest speed setting. • These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit. Model SG-CAC-08ESE Power Supply (Ph/V/Hz) 1/115/60 Dehumidifying Capacity (Pints/Day) 46 Rated Cooling Capacity (BTU/hr) 8,000 Cooling Power Input (Watt
Resumen del contenido incluido en la página 4
IMPORTANT SAFETY INSTRUCTIONS Read all instructions before using this air conditioner These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT window. Modification may be necessary when installing in windows made differently than those shown in these instructions. MEETING ELECTRICAL REQUIREMENTS OBSERVE ALL LOCAL GOVERNING CODES AND ORDINANCES. DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD
Resumen del contenido incluido en la página 5
PREPARING FOR INSTALLATION PREPARING FOR INSTALLATION Installation Tips For wood-frame casement windows: It may be necessary to construct a frame, using at least 1-inch thick wood, with a 15-1/2-inch wide opening. For brick or cement building construction: It may be necessary to put a wood stool strip under AC, for mounting pur- poses. Tools Required: • Flat-head screwdriver • Phillips-head screwdriver • Carpenter's level • Tape measure • Fine tooth saw • Electric or hand drill
Resumen del contenido incluido en la página 6
PARTS LIST & INSTALLATION 6
Resumen del contenido incluido en la página 7
INSTALLATION INSTALLING THE UNIT IN A SLIDING WINDOW 1. Attach support brace to platform as shown. Use adjustment bolt and hex flange nut to complete assembly. Choose slot and adjustment bolt hole locations that will create a 45 degree angle between platform and support brace. Try assembly in the window to determine if platform will rest properly, and allow proper slope (3/16-inch lower on outside). NOTE: If you are planning to use a siding protection board (see Step 5) on the outside
Resumen del contenido incluido en la página 8
INSTALLATION—SLIDING INSTALLING THE UNIT IN A SLIDING WINDOW (CONT.) 4. Peel off protective backing from track seal. Apply seal to room side of window track. Center of seal strip should coincide with the line marked in Step 2. The two screw holes drilled in Step 3 should be directly above seal strip in the inner track. 5. Securely attach a siding-protection board to side of house. NOTE: Siding-protection board should be long enough to span 2 wall studs. 6. Plac
Resumen del contenido incluido en la página 9
INSTALLATION—SLIDING INSTALLING THE UNIT IN A SLIDING WINDOW (CONT.) 10. Clamp plastic window panel between a board and a work table, and cut along cutting line with a fine tooth saw. Remove any burrs with a file. 11. Fasten side channels to the sides of the AC using 3 screws (Item 17) per channel. Start with first screw at top of channel. Make sure hook ends of channels face toward back of unit. 12. Slide plastic window panel into panel frame, with the smooth side to the room. Sl
Resumen del contenido incluido en la página 10
INSTALLATION—SLIDING INSTALLING THE UNIT IN A SLIDING WINDOW (CONT.) 16. Slide inner window sash firmly against side of the cabinet. Make sure not to peel the seal strips from the window track and cabinet side channels. If the panel frame does not fit snugly to the inner window sash, secure the panel frame to the sash with #8x3/4-inch screws, or #8-32x3/4-inch self- threading screws. Use the partially plugged holes in the panel frame. Drill 1/8-inch pilot holes for the screws. 17. Hoo
Resumen del contenido incluido en la página 11
INSTALLATION—CASEMENT INSTALLING THE UNIT IN A CASEMENT WINDOW NOTE: Open the window the maximum amount to allow for clearance of the cabinet. The crank handle should be removed to allow the platform to be fastened to the jamb. If the window cannot open far enough (more than 15-1/2 inches) for the cabinet to clear the window, remove the window entirely by drilling out the rivets. Bolts can serve as the pivots in the future. To avoid crank handle and window clearance problems, the unit
Resumen del contenido incluido en la página 12
INSTALLATION—CASEMENT INSTALLING THE UNIT IN A CASEMENT WINDOW (CONT.) 5. Adjust the platform assembly so that the rear of the air conditioner will be 3/16-inch lower than the front. This ensures proper water drainage from the air conditioner. NOTE: A projection below the base of the air conditioner will require the rear of the platform to be 7/16-inch lower than the front to create the 3/16- inch slant from front to rear. 6. Securely attach a siding-protection board to the side of the
Resumen del contenido incluido en la página 13
INSTALLATION—CASEMENT INSTALLING THE UNIT IN A CASEMENT WINDOW (CONT.) 11. Cut side channel seal into 2 equal lengths. Remove the protective backing and apply it to the rear side of the cabinet side channels, starting just below the panel frame assembly. Pinch off excess length so the seal is even with the bottom of the cabinet side channel. 12. To Remove the Front Panel 1. Remove the two front retaining screws from the front frame. 2. Press firmly on each side of the metal case clos
Resumen del contenido incluido en la página 14
IMPORTANT SAFETY INSTRUCTIONS Read all instructions before using this air conditioner FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Read product labels for flammability and other warnings. ACCIDENT PREVENTION To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow basic precautions, including the following: • Be sure the electrical service is adequ
Resumen del contenido incluido en la página 15
IMPORTANT SAFETY INSTRUCTIONS READ THIS SECTION BEFORE ATTEMPTING TO OPERATE YOUR AIR CONDITIONER The power supply cord contains a current device that senses damage to the power cord. Follow the instructions below to test your power cord. 1. Plug in your air conditioner 2. The power supply cord will have TWO buttons on the plug. Press the TEST button. You will notice a click as the RESET button pops out. 3. Press the RESET button. The button will click when the RESET button engages.
Resumen del contenido incluido en la página 16
OPERATING YOUR AIR CONDITIONER Before you start using your air conditioner, please familiarize yourself with the control panel and remote control functions. This air conditioner can be controlled by the control panel (touch pad) or the included remote control. CONTROL PANEL (TOUCH PAD) 1) Power On and Off - Press the POWER to turn the unit ON and OFF. 2) Digital Display - Displays the Set Temperature in Auto, Cooling, Energy Saver, Fan or Dry Mode, as well as the Time for th
Resumen del contenido incluido en la página 17
OPERATING YOUR AIR CONDITIONER REMOTE CONTROL 5. FAN - Press the FAN button to turn change the FAN options. You can choose between four speeds and auto mode. The fourth fan option is only available in cooling and energy saver modes. 6. IFEEL MODE - Press the IFEEL button to change the thermostat sensor from the air conditioner to the remote location. The air con- ditioner will cool the area depending on the location and set temperature of the remote control. Take the remote
Resumen del contenido incluido en la página 18
OPERATING YOUR AIR CONDITIONER REMOTE CONTROL 9. LOCK/UNLOCK - Press the “+” and “—” buttons simultaneously to lock and unlock the remote control. When the remote is locked, none of the functions or setting can be changed using the remote. 10. F° or C° - To switch between the F° or C° settings, press the MODE and “—” buttons a t the same time. 11. DISPLAY LIGHTS- Hold the “+” and FAN buttons to turn the lights on the display ON or OFF. This can be done when the unit is on or off.
Resumen del contenido incluido en la página 19
OPERATING YOUR AIR CONDITIONER AIR CONDITIONER FEATURES There is a 3 minute delay when cooling mode is engaged or disengaged. This delay prevents the compressor from overheating and possible tripping of the circuit breaker. The fan will continue to run during this time. The temperature control will maintain the set temperature within 2°F, between 60°F and 90°F degrees. EXHAUST CONTROL The Exhaust control allows the air conditioner to recirculate inside air when it is set to CL
Resumen del contenido incluido en la página 20
TAKING CARE OF YOUR AIR CONDITIONER Cabinet Cleaning CARE AND CLEANING To clean the air conditioner cabinet: Clean your air conditioner to keep it looking new and to minimize dust build up. • Unplug the air conditioner to prevent shock or a fire hazard. The cabinet and front panel of Air Filter Cleaning the air conditioner may be dusted with an oil- The air filter should be checked at least once free cloth or washed with a cloth dampened in every month to see if it needs cleaning.