Resumen del contenido incluido en la página 1
HP Ultrium drives
Technical reference manual
Generation 3 drives
Volume 4: Specifications
Part Number: Q1530–90901 Volume 4
Edition 5, December 2004
Resumen del contenido incluido en la página 2
Notice © Copyright 2001–2004 Hewlett-Packard Development Company L.P. The information contained in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or direct, indirect, special, incidental or consequential damages in connection with the furnishi
Resumen del contenido incluido en la página 3
Contents Related documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Documents specific to HP Ultrium drives. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Documentation map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 General documents and standardization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 1Features 2 Physical spe
Resumen del contenido incluido en la página 4
7Media Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Environmental specifications (media). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Operating. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Storage (day-to-day). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Storage (transportation)
Resumen del contenido incluido en la página 5
Related documents The following documents provide additional information: Documents specific to HP Ultrium drives Hardware Integration Guide, volume 2 of the HP Ultrium Technical Reference Manual Software Integration Guide, volume 2 of the HP Ultrium Technical Reference Manual The SCSI Interface, volume 3 of the HP Ultrium Technical Reference Manual HP Ultrium Configuration Guide, volume 5 of the HP Ultrium Technical Reference Manual Background to Ultrium Drives, volume 6 of the HP Ul
Resumen del contenido incluido en la página 6
Operation SCSI Drives FC Drives External drives (SCSI only) 1 HW Integration: ch. 5n/a In Libraries 1 HW Integration: ch. 1 In Servers (SCSI only) 1 HW Integration: ch. 4n/a In Tape Arrays (SCSI only) 1 HW Integration: ch. 3n/a Cartridges SCSI Drives FC Drives Cartridge Memory (LTO-CM) 2 SW Integration: ch. 5 6 HW Integration: ch. 5 Cartridges 1 HW Integration: ch. 9 1 HW Integration: ch. 5 Features 6 HW Integration: ch. 5 Managing the use of cartridges 2 SW Integration: ch. 1 Use of cartridges
Resumen del contenido incluido en la página 7
SCSI Drives FC Drives Monitoring drive and tape condition 2 SW Integration: ch. 7 Software troubleshooting techniques 2 SW Integration: ch. 1 Dealing with errors SCSI Drives FC Drives Error Codes 1 HW Integration: ch. 10 1 HW Integration: ch. 6 Handling errors 2 SW Integration: ch. 5 How error correction works 6 Background: ch. 4 Logs—see the LOG SENSE command 3 SCSI: ch. 4 Recovering from write and read errors 2 SW Integration: ch. 7 Software response to error correction 2 SW Integration: ch. 3
Resumen del contenido incluido en la página 8
See http://www.t10.org/t10_main.htm for ANSI SCSI-3 and other specifications Copies of documents of other standards bodies can be obtained from: ANSI 11 West 42nd Street New York, NY 10036-8002 USA ISO CP 56 CH-1211 Geneva 20 Switzerland ECMA 114 Rue du Rhône Tel: +41 22 849 6000 CH-1204 Geneva Web URL: http://www.ecma.ch Switzerland Global Engineering Documents 2805 McGaw Tel: 800 854 7179 or 714 261 1455 Irvine, CA 92714 USA 8
Resumen del contenido incluido en la página 9
1Features Feature Specification Recording format Linear Tape Open Ultrium-3 and Ultrium-2.Ultrium-1 tapes can be read but not written. Data compression ALDC Data encoding method 16-channel PRML Variable speed recording 27–80 MB/s (1:3) Ultrium-3 Read-While-Write Standard—data is verified immediately after it is written Auxiliary memory in cartridge (CM) Standard part of the Ultrium format Data interfaces SCSI: Ultra320 SCSI Serial-Attach-SCSI (SAS) FC: 2 Gb/s Fibre Channel, Class 3, dual port,
Resumen del contenido incluido en la página 10
2 Physical specification Dimensions SCSI Fibre Channel Internal width: 146 mm (5.75") 146 mm (5.75") height: 82.5 mm (3.25") 82.5 mm (3.25") depth: 203 mm (8") 213.8 mm (8.4") External width: 208 mm (8.2") n/a height: 121 mm (4.75") n/a depth: 298 mm (11.75") n/a Rack-Mount width: 208 mm (8.2") n/a height: 121 mm (4.75") n/a depth: 298 mm (11.7") n/a Detailed dimensions Figure 1-1 Plan 10 Physical specification
Resumen del contenido incluido en la página 11
Figure 1-2 Side With Fiber Channel, the connector stands out at the back of the drive: Figure 1-3 Fibre Channel connector [No drawing available as of November 30, 2004] Figure 1-4 Front 11
Resumen del contenido incluido en la página 12
Figure 1-5 Rear View—SCSI Figure 1-6 Rear view—Fibre Channel [No drawing available as of November 30, 2004] Product weight Internal* 2.239 kg (4.94 lb) External 5.572 kg (12.28 lb) *including front panel and ESD bag but excluding rails Drive orientation An HP Ultrium drive will operate in the 0°, –90° and +90° when viewed from the front panel. In addition, in the 0° axis, the drive will operate with +20°nose-up tilt. 12 Physical specification
Resumen del contenido incluido en la página 13
3 Electrical requirements PSU requirements Internal and rack-mounted drives The drives are specified to operate at 5V±5% and 12V±10%. Any PSU used to power the drive must be capable of providing 5V nominal (when the drive pulls 5A on the 5V rail) and 12V nominal (when the drive pulls 2A on the 12V rail). HP recommends a 10% buffer when selecting a power supply source capable of delivering the amperage and power required. SCSI Drives FC Drives Specification 5V 12V 5V 12V Maximum voltage 5.25V
Resumen del contenido incluido en la página 14
SCSI Drives FC Drives Activity Average Peak Average Read 24.3W 30.8W TBD Reposition/Rewind 24.4W 31.6W TBD Unload 16.8W 28.2W TBD 14 Electrical requirements
Resumen del contenido incluido en la página 15
4 Electromagnetic compatibility NOTE: The EMC performance of internal storage products depends on the characteristics of the system in which the product is installed. HP has tested products installed in network storage system enclosures and in external desktop enclosures to verify EMC performance against the regulatory standards in force at the time of introduction. ITE emissions Standards Parameter International European Economic Area Radiated and conducted CISPR 22:1997 EN 55022:1998 + Amen
Resumen del contenido incluido en la página 16
DC magnetic field interference IATA Dangerous Goods Regulations, 30th Edition, 1989-01-01 U.S. CFR 49, paragraph 173.1020, revision date: 1983-11-01 16 Electromagnetic compatibility
Resumen del contenido incluido en la página 17
5Environmental Climatics These apply to the mechanism unless otherwise noted. For the environmental specification of media, see Chapter 7, “Media”. Operating Parameter Specification Operating temperature with media at 6 cfm airflow: 10°C to 35°C (50°F to 95°F) at 8 cfm airflow: 10°C to 40°C (50°F to 104°F) Maximum operating temperature rise 10°C/hr (50°F/hr) Operating non-condensing humidity 20% to 80% RH Maximum operating humidity rise <30%/hr Maximum wet bulb temperature 26°C (79°F) Operating
Resumen del contenido incluido en la página 18
Dynamics Parameter Specification Operating sine vibration 0.31G pk 5–500 Hz @ 1 octave/min with 15 min dwell at peak resonance 2 Operating random vibration 0.31G rms 5–500 Hz 0.000194 g /Hz Operating shock 5G 3 ms half-sine (no performance change) 2G 11 ms half-sine (no performance change) 8G 11 ms half-sine (no data loss) Pulse rate: 0.1 Hz Non-operating sine vibration 1.0G pk 5–500 Hz @ 1 octave/min with 5 min dwell at peak resonance Non-operating random vibration 2.41G rms 5–500 Hz Non-oper
Resumen del contenido incluido en la página 19
6Safety Safety regulatory standards Agency Referenced Standard Underwriters Laboratories (UL) UL 60951 First Edition Canadian Standards Association (CSA) CSA 22.2 60950-1-03 CE and TÜV EN 60950-1:2001, including all amendments IEC 60950-1:2001, including all amendments CB Report and Certificate IEC 60950-1:2001, including all amendments (including all National Deviations) Required agency approvals Agency National Standard NOM-1-NYCE Product Safety: NOM-0190SCFI-1998 GOSH Product Safety: GOST R
Resumen del contenido incluido en la página 20
7Media Specification HP Product Number Format Capacity* Notes C7973A U3 800 GB Read and write C7973W U3 WORM 800 GB Write once, read many times C7972A U2 400 GB Read and write C7971A U1 200 GB Read-only in Gen 3 drives *Capacities at 2:1 data compression. The actual capacity depends on the compression ratio of the data. This is typically 2:1 but can be anywhere between 1:1 and 110:1. Ultrium 1 Ultrium 2 Ultrium 3 Tape Base film: 6 µ m (Poly-Ethylene-Naphthalate) PEN Tape length: 609m 609m 680m