Resumen del contenido incluido en la página 1
Model: GH-PAC-12E1
Model: GH-PAC-12E1HP WITH HEAT
12,000 BTU Portable Air Conditioner
Operating Instructions
Resumen del contenido incluido en la página 2
Thank you for choosing a Soleus Air Powered by Gree Portable Air Conditioner. This owner’s man- ual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Portable Air Conditioner. For your own records, please attach a copy of your sales receipt to this manual. Also, write the store name/location, date p
Resumen del contenido incluido en la página 3
PACKAGE CONTENTS Portable Air Conditioner Exhaust Hose (1) Front Exhaust Hose Adapter (1) Window Kit Adapter (1) Rear Exhaust Hose Adapter (1) Remote Control & AAA Ba tteries (2 batteries) Window Kit - 3 Sliding Panels (1 sing le hose panel, 2 extension panels) Owner’s Manual SPECIFICATIONS • The cooling capacity is measured at an ambient temperature of DB 86 °F, WB 78 °F. • Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit is in c
Resumen del contenido incluido en la página 4
POWER CORD AND PLUG WARNING This unit has a grounded three pronged plug intended to fit into a three slot outlet. (A) An adapter is available for connecting three pronged plugs into two slot outlets. (B) When doing so, the green ground- ing tab extending from the adapter must be fastened under the wall plate’s mounting screw. The adapter should not be used if a three-slot out- let is available. DO NOT DEFEAT THE SAFETY PURPOSE OF THE GROUNDED PLUG. 4
Resumen del contenido incluido en la página 5
PRODUCT DIAGRAM Air Outlet & Louvers Carry Handle Control Panel Filter Upper Air Intake Location Air Exhaust Vent Lower Air Intake Power Cord 5
Resumen del contenido incluido en la página 6
PARTS & WINDOW KIT ASSEMBLY PARTS EXHAUST HOSE & ADAPTERS Front Exhaust Hose Rear Exhaust Hose Exhaust Hose Adapter Adapter Window Kit Adapter Sliding Panels (3) ASSEMBLY & INSTALLATION INSTALLATION When the unit is operating as an air conditioner or dehumidifier, the window kit and exhaust hose must be installed. When the unit is operating in fan mode, the window kit and exhaust hose do not need to be installed . MOUNTING
Resumen del contenido incluido en la página 7
SINGLE HOSE WINDOW KIT INSTALLATION This installation is OK The is a poor installation 22” When installing the exhaust hose, try and keep it as flat as possible. The less angles and bends in the hose, the better the unit will perform. If bending or an angle is necessary, use single 90° angles like the pictures above. Multiple bends will decrease performance and efficiency 7 26”
Resumen del contenido incluido en la página 8
CONTROL PANEL GH-PAC-12E1 COOL MODE LIGHT DRY MODE LIGHT LED DISPLAY FAN MODE LIGHT BUCKET FULL LIGHT POWER BUTTON MODE BUTTON TEMP SELECT BUTTONS GH-PAC-12E1HP HEAT MODE LIGHT DRY MODE LIGHT LED DISPLAY COOL MODE LIGHT FAN MODE LIGHT POWER BUTTON MODE BUTTON TEMP SELECT BUTTONS 8
Resumen del contenido incluido en la página 9
CONTROL PANEL FUNCTIONS CONTROL PANEL OPERATING INSTRUCTIONS 1) Power On and Off - Press the POWER button once to manually turn the unit on. Press the POWER button once more to turn the unit off. 2) Mode Selection - Press the MODE Button repeatedly to cycle between the different modes: Air Conditioner, Dehumidifier (DRY), Fan only, and Heater mode (NOTE: Heater mode is only available on the GH-PAC-12E1HP). Each press of the MODE button will light up a different mode ico
Resumen del contenido incluido en la página 10
REMOTE CONTROL OPER ATING INSTRUCTIONS - / + - / + BUTTONS SIGNAL TRANSMITTER When the unit is in Air Conditioner or Heater (GH-PAC- 12E1HP) mode you can select your desired temperature. Press the TEMP SELECT buttons (+ or -) to select your desired temperature setting. The temperature on the LCD display on the remote control will increase or de- crease accordingly. Hold the +/- buttons for two seconds to rapidly increase or deceas r e the temperature. Temp. range is 61°F—86°F. FAN
Resumen del contenido incluido en la página 11
REMOTE CONTROL OPERATING INSTRUCTIONS TIMER TIMER BUTTON Auto-on Timer: When the air conditioner is off, it can be set to automatically turn on in 30 minutes to 24 hours at the previous set mode and fan setting. To set the Auto- on Timer, press the TIMER button on the unit or remote control. Each touch of the +/- buttons on the remote will change the timer setting in 30 minute increments (.5 hours). HOUR ON/OFF icon will blink when the Auto- on Timer is being set. Once the timer is set, p
Resumen del contenido incluido en la página 12
REMOTE CONTROL OPER ATING INSTRUCTIONS Blow Blow REMOTE CONTROL Press the blow button to enable the blow function. When enable, blow will force the fan to remain on once the unit is powered down. The fan stays on to dry out any remaining moisture in the unit to help minimize mold or bacteria growth. This function only works under cooling mode. BLOW LOCK LOCK FUNCTION • Press “+” and “-” buttons together at the same time to lock the remote keyboard. Do this again to unlock. SLEE
Resumen del contenido incluido en la página 13
MAINTENANCE Note: Make sure power is off and the power cord is not plugged into an electrical outlet prior to performing any maintenance on the unit. Clean or replace filter - If the air filter is blocked with a dust, the airflow volume may decrease. It is recommended to clean the filter once every two weeks, or as needed. 1) Remove the filter from the filter compartment on the back of the unit. 2) Wash the air filter by immersing it gently into warm water with a neutral detergent
Resumen del contenido incluido en la página 14
TROUBLESHOOTING PROBLEM POSSIBLE CAUSES SOLUTIONS The Air Conditioner will not start The air conditioner is unplugged or not • Make sure the air conditioner plug connected well. is pushed completely into the out- let • Check the house fuse/circuit breaker box and replace the fuse The fuse is blown/circuit breaker is or reset the breaker. tripped. • The unit will automatically re-start when power is restored. Power Failure • There is a protective ti
Resumen del contenido incluido en la página 15
TROUBLESHOOTING (CONT.) PROBLEM POSSIBLE CAUSES SOLUTIONS The LCD Display is showing “E5” Low Voltage Protection • Unplug for 10 minutes and then turn on the unit. If “E5” is still dis- played, contact customer service. The LCD Display is showing “H8” The backup water tank is full • Drain the water tank • If the “H8” I still displayed after the water tank has been emptied, con- tact customer service. The LCD Display is showing “F1”, Internal malfunction • Contact C
Resumen del contenido incluido en la página 16
WARRANTY One Year Limited Warranty Soleus International Inc. warrants the accompanying Soleus Air Powered by Gree Portable Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States. If the unit exhibits a defect in normal use, Soleus International Inc. will, at its option, either repair or replace it, free of charge within a r