SERVICE MANUAL
KING
SERIES
ASH-09AK, ASH-13AK
Resumen del contenido incluido en la página 2
Resumen del contenido incluido en la página 3
Summary and features 1 Summary and features 09/13 Outdoor unit: Model Remarks ASH-09AK 1Ph 220~240V 50Hz ASH-13AK R410a
Resumen del contenido incluido en la página 4
T Technical specifications echnical specifications 2 Model ASH-09AK ASH-13AK Function COOLING HEATING COOLING HEATING Rated Voltage 220-240V 220-240V Rated Frequency 50Hz 50Hz Total Capacity (W/Btu/h) 2650 /9050 2850/ 9730 3516/12000 4015/13700 Power Input (W) 820 785 1080 1104 Rated Input (W) 1110 1150 1500 1500 Rated Current (A) 5.69 5.9 7.6 7.6 Air Flow Volume (m3/h) (H/M/L)** 500 580 Dehumidifying Volume (l/h) 1 1 EER / C.O.P (W/W) 3.21/3.61 3.26/3.64 Energy Class A A Model of Indo
Resumen del contenido incluido en la página 5
Model of Outdoor Unit ASH-09AK ASH-13AK Compressor Manufacturer/trademark HIGHLY Gree Compressor Model ASG102CV-B7AT QXA-133uB030 Compressor Type Rotary Rotory L.R.A. (A) 18A 32 Compressor RLA(A) 4.05 5.1 Compressor Power Input(W) 875 1160 Overload Protector KA-172-LYGN914 B250-150-141E Throttling Method Capillary Starting Method Capacitor Working Temp Range ( ) -5~43 -15~46 ℃ Condenser Aluminum fin-copper tube Pipe Diameter (mm) 77 Rows-Fin Gap(mm) 1-1.6 2-1.4 Coil
Resumen del contenido incluido en la página 6
3 Part name Part name Air in Manual switch Front Panel Indoor unit Filter Wrapping Tape Air out Guide louver LED displayer Wall Pipe Heat Cooling LED displayer Wireless remote control Set Temp DRY Run Remote control window Outdoor unit Air in Drainage hose Air out Connection pipe
Resumen del contenido incluido en la página 7
D Outline and installation dimension 4 Outline and installation dimension Outline and installation dimensions of indoor unit Air inlet W Tube exit Wall-Mounting Plate: ASH-09AK ASH-13AK Rear View Ceiling Left Right Wall-Mounting Plate Model W()H()D( ) ㎜ ㎜ ㎜ ASH-09AK 740 250 180 805 ASH-13AK 280215 H
Resumen del contenido incluido en la página 8
Outline and installation dimensions of outdoor unit ASH-09AK, ASH-13AK Unit:mm Bolt Nut Wrench
Resumen del contenido incluido en la página 9
55 555 Electrical circuit diagram Electrical circuit diagram ASH-09AK ASH-13AK
Resumen del contenido incluido en la página 10
Manual of functions of remote controller and operation method 66666 Manual 1 of functions of remote controller 6.1.1 Temperature parameter The room setting temperature(Tpreset) The room ambient temperature (Tamb) 6.1.2Basic Functions Once energized, the compressor should in no way be restarted unless after 3-minute time interval at least. For the first energization, the compressor will be started without 3-minute lag. The compressor, once started,will not be stopped within 6 minutes with
Resumen del contenido incluido en la página 11
Cooling T amb T +2 ℃ preset Dry T -2 ℃ preset 6 min. 6 min. Stop 4 min. 4 min. Compressor Outdoor fan Indoor fan low speed Run Stop 6.1.2.2.3 Protection Antifreeze Protection Upon meeting the cooling condition, if it is detected that the system is under antifreeze protection, the compressor and outdoor fan will be stopped,and the indoor fan will run at low speed. When antifreeze protection is released and the compressor has stopped for 3 minutes, the complete unit will resume
Resumen del contenido incluido en la página 12
3.Other controls 1. Memory function Memory contents: Mode, up and down swing, Light, Setting temp., Setting fan speed, Ordinary setting Fahrenheit/Centigrade, after powered off, and powered on, it will run at the memory contents. If no timer setting function in last remote control order, the system will memorize the last remote control order, the system will memorize the last remote control order and work with last remote control setting. In the last remote control order, there is ordinary ti
Resumen del contenido incluido en la página 13
(6) Turbo function The turbo function is available in Cool and Heat modes. (7) Dry function Dry function is available in Cool and Dehumidifying modes. (8) Auto fan speed control In this mode, indoor fan can run with Hig, Mid, Low speeds. (9) Up and down swing control After powered on, the lower swing motor will firstly rotate the guide louver to position 0, close up the air outlet vent; After unit turned on, if to set up swing function, when indoor fan stop running, the guide louver will stop at
Resumen del contenido incluido en la página 14
Manual 2 of functions of remote controller This manual is applicable to 18K, 24K models, the centigrade is used for the following function manual, if there will be the Fahrenheit degree, that will be TF= TCX1.8+32. 1 . Temperature parameter The room setting temperature(Tpreset) The room ambient temperature (Tamb) Basic Functions Once energized, the compressor should in no way be restarted unless after 3-minute time interval at least for the first energization, the compressor will be started
Resumen del contenido incluido en la página 15
DRY Modes When Tamb. Tpreset 2 , the unit will run under DRY cooling mode, in which case the compressor and outdoor fan will be started and the indoor fan will run at low speed. When Tpreset 2 Tamb. Tpreset 2 , the unit will run under Dry mode, in which case the indoor fan will keep run at low speed, the compressor and outdoor fan will be stopped after 6mins. After 4 minutes, the compressor and outdoor fan will be restarted. The dehumidifying process is so repeated in cycle.
Resumen del contenido incluido en la página 16
If it is detected that the evaporator tube temperature is too high, the outdoor fan will be stopped. When the tube temperature resumes to normal, the outdoor fan will be restarted. Noise Silencing Protection If the unit is stopped by pressing ON/OFF, the reversal valve will be stopped after 2-minute lag; or 2 minutes wi l l be delayed upon mode switching. Over current product The overcurrent protection is the same with the the over current protection under cool mode. Fan mode Under FA N mo
Resumen del contenido incluido en la página 17
1hr. 2hrs. 2hrs. above Tpreset Tpreset Tpreset temp. Tpreset Turbo function The turbo function is available in Cool and Heat modes. Dry function Dry function is available in Cool and Dehumidifying modes. Auto fan speed control In this mode, indoor fan can run with Hig, Mid, Low speeds. Up and down swing control After powered on, the lower swing motor will firstly rotate the guide louver to position 0, close up the air outlet vent; After unit turned on, if to set up swing function, when indoor f
Resumen del contenido incluido en la página 18
7 7 7 7 7 Dissassembly Procedures Dissassembly Procedures (09) Disassembly procedures for indoor unit Operating Procedures / Photos 1. Disassemble the front panel, filter Front Pane Screw Protect board Push the rotating shaft of front panel outsidely to put out it from the groove, screw off one screw on the display guard board, then take down the displayer connection wire, can take down the front panel. Filter 2. Disassemble the guide louver Bend the guide louver so that the movable lock of g
Resumen del contenido incluido en la página 19
Operating Procedures / Photos 4. Disassemble the electric cover Screw off the screw, then press the clasps in by Screw till they loose, then lift up wards the electric cover. Electric cover Clasp 5. Disassemble the electric box Grounding wire Tube Sensor Screw off the grounding wire of the evaporator, remove the temperature sensor for the pipe, put out the connection lines for the step motor and the indoor motor. Screw off the screw fixing the electric box. Remove the electric box. Screw Connec
Resumen del contenido incluido en la página 20
Operating Procedures / Photos 6. Disassembling the evaporator Screw off one screw which fix the connection pipe clamp. Screw Take off the connection pipe clamp. CAUTION: When repair, Carefully take out the evaporator and pay attention to protect the connecting pipe. Screws 7. Disassembling motor and cross flow fan Motor Press Plate Screw off 4 screws fixing the motor cover and then take the motor cover out. Screw off the holding screw at the left shaft sleeve of the cross flow fan, pull out t