4 4
F Fo orrccee G15 & G15+ RAID Systems
15-bay Rackmount and Tower Enclosures
Installation Guide
May 31, 2002 • Revision A
Patent Pending
Resumen del contenido incluido en la página 2
Copyright Copyright 2000, 2001 by JMR Electronics, Inc. All Rights Reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language, in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the express written permission of JMR Electronics, Inc. Sales and Ordering Information JMR Electronics, Inc. 20400 Plummer Street Chatsworth, CA 91311 USA Phone: 818-993-4801 Fax: 818
Resumen del contenido incluido en la página 3
Table of Contents 1. Introduction FORTRA Product Family Features . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 4 FORTRA Force G15 RAID System Components . . . . . . . . . . . . . . . .1-2 4 FORTRA Force G15+ RAID System Components . . . . . . . . . . . . . .1-2 Rackmount Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 Tower Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Resumen del contenido incluido en la página 4
Option Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-4 Delayed Start Option Jumper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-4 Remote Start Option Jumper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-4 Front Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-4 External I/O Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Resumen del contenido incluido en la página 5
4 4 The FORTRA F Fo orrccee G15 & G15+ RAID Systems are prepackaged 2G Fibre to 2G Fibre RAID solutions designed to be used with the included Intel PCI Dual 2G Fibre Channel host controller to provide a high-end RAID system solution. 4 4 The following is a summary of the FORTRA F Fo orrccee G15 & G15+ RAID Systems features: 4 4 • The FORTRA F Fo orrccee G15 RAID Systems Tower enclosure supports up to fifteen 3.5" LP SCA 40-pin SCA drives. This 2G Fibre Channel enclo
Resumen del contenido incluido en la página 6
4 4 FORTRA F Fo orrccee products use advanced mid-plane technology developed by JMR, which allows power supplies, drives, and all other enclosure components to interface into a single board. This provides superior performance and easy connectivity. The host interface supports a SFP (Small Formfactor Plug) Fibre Channel transceiver at 2Gb/s. 4 4 All FORTRA F Fo orrccee G15 & G15+ RAID Systems Fibre enclosures have built- in SES on the personality card that allows control and monitori
Resumen del contenido incluido en la página 7
Tower Specifications Dimensions/Weight Unit Weight 43 lbs. (19.5kg) Height 20-1/2" (521mm) Width 9-5/8" (235mm) Depth 24" (610mm) Power Supply (Each power supply includes internal cooling fan) Quantity: 2 Power: 430 Watts each (N+1) Power Factor Correction Input: 100-260 VAC; 50-60Hz Output: +5V @ 35A +12V @ 30A Blower Quantity: 4 (2 per cannister) Size: 97mm (3.82") each Air Flow: 25.42CFM (0.72m3/min) each Noise: 52dB(A) Fibre Channel Features Loop Expansion 4 4 FORTRA F Fo orrc
Resumen del contenido incluido en la página 8
ID Selection 0-127 device ID addresses are addressable and can be easily set-up via ID rotary switches located on the personality modules. For specific connection and installation information, refer to Chapter 4. SES 4 4 FORTRA F Fo orrccee G15 and G15+ 2Gb/s fibre channel enclosures have a built- in SES processor on the personality card. See Chapter 8 for SES information. 4 FORTRA FORCE G15 & G15+ RAID System Installation Guide Rev A 1-4
Resumen del contenido incluido en la página 9
4 4 This chapter covers specification information for all FORTRA F Fo orrccee G15 Tower and G15+ Rackmount or Tower enclosures. Environmental Specifications Operating Temperature: 5°C to 40°C (41°F to 104°F) Storage Temperature: 0°C to 65°C (32°F to 149°F) The maximum recommended ambient temperature depends on the recommendation of the manufacturer for the devices being installed. Electrical Specifications AC Inlet Type: IEC320/EN60320 Power Cord: NEMA5-15P Power
Resumen del contenido incluido en la página 10
Disclaimer The original product packaging has been tested and is safe under normal shipping circumstances. Reshipping the product without using the original product packaging will void the warranty. Do not ship the unit with canisters and/or power supplies installed in the enclosure as this will void the warranty and could cause damage to the unit and drives. The canisters should be packaged separately within the product packaging, as provided. Thermal Specifications 4 4 FORTRA F Fo orrcc
Resumen del contenido incluido en la página 11
SYS-FLT The SYS-FLT LED on the back of the unit indicates an error on the SES bus. It also indicates whether an active loop connection is established. If no loop connections are established, the LED will light 'Red'. 4 FORTRA FORCE G15 & G15+ RAID System Installation Guide Rev A 2-3
Resumen del contenido incluido en la página 12
This chapter covers Fibre Channel device installation for both the FORTRA 4 4 F Fo orrccee G15 and G15+ rackmount and tower enclosures. SCA Connection and Hot-Swapping The unit uses SCA-2, 40-pin connectors which provide a safe means of connection/disconnection when hot-swapping devices. In order to hot-swap devices, the host adapter or RAID controller and host operating software must support the feature. Any SCA drive is capable of plugging directly into the backplan
Resumen del contenido incluido en la página 13
Follow the steps in reverse to reinstall. Drive Installation Device Mounting Holes (4) Status Indicators Handle Device mounting screws are included with the unit for device mounting. The JMR part number for the #6-32" mounting screws is HDS-01906. WARNING: Before device installation, alleviate any electro-static discharge by touching a grounded metal assembly. Static can be potentially damaging to enclosure components. WARNUNG: Berühren Sie vor der Festplatteninstallation geerdete Metallgegens
Resumen del contenido incluido en la página 14
4. Repeat steps 1 through 3 until all devices are installed, then move onto step 5 to complete unit setup and installation. 5. Configure ID and other options as required. See Chapter 4 for Fibre Channel device setup. 6. Install and configure SES and other optional features. See Chapter 8. 7. For rackmount units, refer to Chapter 7 to install the enclosure into a cabinet. 8. Establish host connection. See Chapter 4 for Fibre Channel host connection. 4 FORTRA FORCE G15 & G15+ RAID System Inst
Resumen del contenido incluido en la página 15
Slot 0, ID 0 Slot 1, ID 1 Slot 2, ID 2 Slot 3, ID 3 Slot 4, ID 4 Slot 5, ID 5 Slot 6, ID 6 Slot 7, ID 7 Slot 8, ID 8 Slot 9, ID 9 Slot 10, ID 10 Slot 11, ID 11 Slot 12, ID 12 Slot 13, ID 13 Slot 14, ID 14 !" This chapter covers Fibre Channel device configuration and option settings. The 4 4 FORTRA F Fo orrccee G15 and G15+ have built-in SES on the personality card. Refer to Chapter 8 for SES operation. Please take note of the installation warnings below before begi
Resumen del contenido incluido en la página 16
Setting ID Rotary switch settings only affect Slot 0 and all other slots are sequentially increased by a value of one after that slot. The ID is set 0-15 ID Switch 0-7 ID Switch sequentially starting (base modifier) (base address) from a base address. The base address, or starting address, is set via a 0-7 position rotary switch located on the back of the unit. There is a second 0- 15 position rotary switch which can be changed to modify the base address setting. Both the top and bottom switch
Resumen del contenido incluido en la página 17
0 1 2 3 4 5 6 7 0 0 16 32 48 64 80 96 112 1 1 17 33 49 65 81 97 113 2 2 18 34 50 66 82 98 114 3 3 19 35 51 67 83 99 115 4 4 20 36 52 68 84 100 116 5 5 21 37 53 69 85 101 117 6 6 22 38 54 70 86 102 118 7 7 23 39 55 71 87 103 119 8 8 24 40 56 72 88 104 120 9 9 25 41 57 73 89 105 121 10 10 26 42 58 74 90 106 122 11 11 27 43 59 75 91 107 123 12 12 28 44 60 76 92 108 124 13 13 29 45 61 77 93 109 125 14 14 30 46 62 78 94 110 126 15 15 31 47 63 79 95 111 127 1G Option Setting By setting the rotary swit
Resumen del contenido incluido en la página 18
WARNING: Before opening the cover, disconnect the AC power cord from both AC inlets to prevent injury. WARNUNG: Vor dem Entfernen der Abdeckung sind beide 220V Netzkabel (Kaltgeräteanschlußkabel) zu entfernen, um Verletzungen zu vermeiden. W1* Delayed Start & Remote Start * Located on the mid-plane board. Delayed Start Option Jumper Header W1 pins 1 & 2. Jumper on = enabled. Jumper off = disabled (default). Remote Start Option Jumper Header W1 pins 3 & 4. Jumper on = enabled. Jumper off
Resumen del contenido incluido en la página 19
External I/O Connection The external I/O connections are located on the personality card There are four SFP tranceiver connectors accessible from the rear of the unit. 0-7 ID 0-15 ID CH-A Switch Switch CH-B SES-ACT Mute SYS- FAULT SYS- FAULT Mute SES-ACT CH-A CH-B 0-15 ID 0-7 ID Switch Switch CH-A and CH-B (Top) Input and output connections for Loop 1. These are SFP (2Gb/s) transceiver connectors used to connect to a host system or to an expansion chassis. CH-A and CH-B (Bottom) Input and o
Resumen del contenido incluido en la página 20
Mute This is a push button used to silence the Audible Alarm. SYS Activity LED This is an LED for SES that will blink whenever there is activity between a host SES unit and the JMR SES processor Loop Expansion (daisy chaining) To connect two JMR enclosures together on the same bus, the OUT port of the first enclosure is connected to the IN port of the second enclosure. SES A built-in SES processor provides in-band bus management for the unit. Refer to Chapter 8 for information about the SES pr