INSTRUCTION MANUAL
Split System Air Conditioner
COOL/FAN Model
Wall-mounted type Ceiling-mounted type Recessed type
KS2432 TS2432 XS1822, XS1852
KS3032 TS3632 XS2432
KS3632 TS4232 XS3632
XS4232
Save These Instructions!
Pub. OI-85464189201002 ©SANYO 2000
Resumen del contenido incluido en la página 2
Features These air conditioners are equipped with cooling function. Details on this function are provided below; refer to these descriptions when using the air conditioner. • • Microprocessor Controlled Operation Air Sweep Control The interior compartment of the remote control This function moves a flap up and down in the unit contains several features to facilitate air outlet, directing air in a sweeping motion automatic operation, easy logically displayed for around the room and providing comf
Resumen del contenido incluido en la página 3
Contents Page Features..................................................................................................................2 Product Information..............................................................................................3 Alert Symbols........................................................................................................3 Installation Location..............................................................................................4 Electrical
Resumen del contenido incluido en la página 4
InstallationLocation • We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit. • Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate. • Do not install this air conditioner where there are fumes or flammable gases, or in an extremely humid space such as a greenhouse. • Do not install the air cond
Resumen del contenido incluido en la página 5
NamesofParts Each air conditioner as shown below consists of an indoor unit and an outdoor unit. You can control the air conditioner with the remote control unit. Ceiling mounted type Recessed type Air outlet Air intake Air intake Air outlet Drain tube Drain tube Remote Refrigerant control tubes Refrigerant Remote control unit tubes unit Wall mounted type Air intake Refrigerant tubes Air outlet Drain Remote control unit hose This illustration is based on the external view of a standard model. NO
Resumen del contenido incluido en la página 6
UnitDisplayandOperationSelector Recessed type Ceiling mounted type OPERATION TIMER Remote control lamp lamp receiver Recessed type Ceiling mounted type Operation selector Finger-hold Air intake grille Air intake grille Air filter Operation selector 6 OI-201-06EG
Resumen del contenido incluido en la página 7
UnitDisplayandOperationSelector(continued) INDOOR UNIT REMOTE CONTROL receiver OPERATION lamp Operation selector TIMER lamp REMOTE CONTROL This section picks up infrared signals from the remote control unit receiver (transmitter). Operation selector ON position This position is for operating the air conditioner with the wireless remote control unit. Set the selector normally in this position. OFF position Switch the selector to the OFF position if you are not going to use the air conditioner for
Resumen del contenido incluido en la página 8
RemoteControlUnit(Display) Displayed when main unit sensor is in use Displayed when setting temperature Displayed when transmitting data SET TEMP 1HR. Displayed when temperature is shown F Displayed when the temperature setting is at the upper or lower allowable limit Displayed when setting timer ON OFF AM PM Symbols (3) Set temperature (1) Operation mode 60–88°F When set to 82 °F........... F COOL....................................... Current temperature indication.......................
Resumen del contenido incluido en la página 9
RemoteControlUnit AIR CONDITIONER Sensor Transmitter AIR CONDITIONER SET TEMP 1HR. F ON OFF Display AM A PM (Cover closed) 1HR. TIMER TEMP. 1 HR. TIMER button TEMP. setting buttons ON I /OFF ON/OFF operation button NIGHT OFF ON NIGHT SETBACK button MODE selector button CLOCK SETBACK MODE FLAP HH TIMER Program button TIMER SELECT button FLAP button SELECT FAN SPEED MM Timer setting buttons ACL A/C TIME SET SELECT SENSOR BATTERIES FAN SPEED A/C SENSOR button selector button ACL button
Resumen del contenido incluido en la página 10
RemoteControlUnit(continued) PROGRAM button For details, see ‘‘Setting the Timer’’. Press this button to select the mode you want to program. TIMER SELECT button No display : The timer does not operate. : The air conditioner stops at the set time. OFF : The air conditioner starts at the set time. ON : The air conditioner stops and starts, or starts and stops, at the set times every day. MODE selector button Use this button to select COOL or FAN mode (COOL) : The air conditioner makes the
Resumen del contenido incluido en la página 11
UsingtheRemoteControlUnit How to Install Batteries ACL button 1. Slide the cover in the direction indicated by the arrow and remove it. 2. Install two AAA alkaline batteries. Make sure the batteries point in the direction marked in the battery compartment. 3. Use a thin object such as the tip of a pen to press the ACL button. • The batteries last about six months, depending on how much you use NOTE the remote control unit. Replace the batteries when the remote control unit’s display fails to lig
Resumen del contenido incluido en la página 12
UsingtheRemoteControlUnit(continued) Mounting the Remote Control Unit Removable mounting Non-removable mounting Wall Wall (Packed in the indoor unit) (Packed in the indoor unit) Mounting on a wall A. Removable mounting 1) Momentarily hold the remote control unit at the desired mounting position. 2) Confirm that the air conditioner responds correctly when you press keys on the remote control from that position. 3) After confirming correct operation, use a screwdriver to screw the mounting screw i
Resumen del contenido incluido en la página 13
OperationwiththeRemote ControlUnit 1. Operation AIR CONDITIONER 1HR. F 1 AM A 1HR. TIMER TEMP. STEP 3 ON I /OFF STEP 2 NIGHT OFF ON CLOCK SETBACK MODE STEP 1 FLAP HH TIMER STEP 5 SELECT FAN SPEED MM STEP 4 ACL A/C SELECT TIME SET SENSOR BATTERIES Check that the circuit breaker on the power panel is turned on and that the NOTE operation selector of the indoor unit is in the ON position. Press the setting buttons as described below and change the settings as desired. STEP 1 Set the MODE sele
Resumen del contenido incluido en la página 14
OperationwiththeRemoteControlUnit(continued) • Choose the best position in the room for the remote control unit, which NOTE also acts as the sensor for room comfort and transmits the operating instructions. Once you’ve found this best position, always keep the remote control unit there. • This appliance has a built-in 3-minute time delay circuit to ensure reliable operation. When the operation button is pressed, the compressor will start running within three minutes. In the event of power failur
Resumen del contenido incluido en la página 15
OperationwiththeRemoteControlUnit(continued) 4. Night Setback Mode AIR CONDITIONER 1HR. F A PM 1HR. TIMER TEMP. ON I /OFF NIGHT OFF ON CLOCK SETBACK MODE FLAP HH TIMER SELECT FAN SPEED MM Night Setback Mode is used for saving energy. Press the NIGHT SETBACK button while operation. The mark appears in the display. To release the night setback function, press the NIGHT SETBACK button again. The night setback mode cannot be used during automatic operation. NOTE In Cooling Mode: ( ) When the n
Resumen del contenido incluido en la página 16
SpecialRemarks • In the event of power failure, the unit will stop. When the power is Power failure resumed, the unit will restart automatically after three minutes. during operation • The remote control unit sends the setting condition to the air Remote Control Unit conditioner regularly at three minute intervals. 16 OI-201-16EG
Resumen del contenido incluido en la página 17
SettingtheTimer ON I /OFF NIGHT OFF ON MODE CLOCK SETBACK FLAP HH TIMER SELECT FAN SPEED MM A/C ACL SELECT TIME SET SENSOR BATTERIES 1. How to set the (Example) To set to 9:10 p.m. present time Operation Indication OFF ON 1.Press the Program button ( ) three The time indication alone CLOCK times. flashes. 2. • The display will auto- Press the HH button until PM 9 is PM matically stop flashing displayed. • except for the ‘‘:’’ symbol Press the MM button until 10 is displayed. after 10 s
Resumen del contenido incluido en la página 18
SettingtheTimer(continued) 3. How to set the ON time (Example) When air conditioner is off, starting operation at 7:10 a.m. Operation Indication OFF ON 1.Press the Program button ( ) twice. The timer ON and time CLOCK indications flash. ON 2. AM • The display will change Press the HH button until AM 7 is automatically back to show displayed. • the present time after 10 Press the MM button until 10 is displayed. sec. 3.Press the TIMER SELECT button three The present time and times to set
Resumen del contenido incluido en la página 19
Usingthe1-HourOFFTimer 1. 1-Hour OFF Timer This function causes the unit to operate for one hour and then stop, regardless of whether the unit is on or off when this button is pressed. The 1HR. indicator in the display indicates that this function is operating. Setting procedure: 1HR. Regardless of whether the unit is operating or stopped, press the 1 HR. TIMER button. 1HR. appears in the display. Cancellation procedure: Press the ON/OFF operation button to turn the unit off, wait for the unit t
Resumen del contenido incluido en la página 20
AdjustingtheAirflowDirection A. Horizontal (Wall mounted type only) The horizontal airflow can be adjusted by moving the vertical vane to the left or right. Indoor unit (Wall mounted type) Left Right Vertical vane B. Vertical Confirm that the remote control unit has been turned on. Press the FLAP 30° Zone button to start the flap moving up and down ( ). If you want to stop the ‘‘A’’ flap movement and to direct the air in the desired direction, press the FLAP for button again. In the COOL mode, d