Resumen del contenido incluido en la página 1
®
IMIX -3S+
®
IMIX -3S+A
®
IMIX -5S+
®
IMIX -5S+A
INSTALLATION & OPERATING GUIDE
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
To ensure you have the latest revision of the Operating Manual, or to view the Illustrated Parts
Catalog, Programming Manual, or Service Manual, please visit the Bunn-O-Matic website, at
www.bunn.com. This is absolutely FREE, and the quickest way to obtain the latest catalog an
Resumen del contenido incluido en la página 2
BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCP/MCA pod brewers thermal servers and Thermofresh servers (mechanical and digital)- 1 year parts and 1 year labor. 2) All other equipment - 2 years parts and 1 year labor plus added warranties as specified below: a) Electronic circuit and/or control boards - parts and labor for 3 years. b) C
Resumen del contenido incluido en la página 3
USER NOTICES The notices on this dispenser should be kept in good condition. Replace unreadable or damaged labels. ! WARNING As directed in the International Plumbing Code of the Fill water tank before turning - on - International Code Council and the Food Code thermostat or connecting appliance Manual of the Food and Drug Administration (FDA), to power source. this equipment must be installed with adequate Use only on a properly protected backflow prevention to comply with federal, state
Resumen del contenido incluido en la página 4
INITIAL SET-UP 1. Apply the four non-skid pads from the parts box to the bottom of the legs. 2. Remove the drip tray assembly, drip tray bracket, and splash panel assembly from the parts box. 3. Place a set of key holes in the drip tray bracket over the lower two screws in the panel below the hopper access door; push down gently and tighten screws. 4. Place the set of key holes in the splash panel over the upper two screws and position so the screws are between the holes. CE REQUIREMENTS • Thi
Resumen del contenido incluido en la página 5
PLUMBING REQUIREMENTS This dispenser must be connected to a cold water system with operating pressure between 20 and 90 psi (138 - 620 kPa) from a 1⁄2” or larger supply line. A shut-off valve should be installed in the line before the dispenser. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa). The water inlet fitting is 1⁄4” flare. NOTE - Bunn-O-Matic recommends 1⁄4” copper tubing for installations of less than 25 feet and 3⁄8”
Resumen del contenido incluido en la página 6
RUNNING A RINSE SEQUENCE 1. Place the Normal/Program/Rinse switch (page 9) in the “rinse” position. 2. Sequentially at each position, press all of the dispense switches. The dispenser will run for 10 seconds with the hopper(s) disabled. 3. As each position is rinsed, the LCD display will show which position is being rinsed and count down from 10 sec- onds. 4. After all positions have been rinsed, return the Normal/Program/Rinse switch to the “Normal” position. DISPENSER USE - Self Serve 1.
Resumen del contenido incluido en la página 7
CLEANING The use of a damp cloth rinsed in any mild, non-abrasive, liquid detergent is recommended for cleaning all sur- faces on Bunn-O-Matic equipment. Do NOT clean this equipment with a water jet device. 1 x 24h 1. Rinse out Whipper Chambers by placing RINSE/RUN 1. Para limpiar las camaras de mezcla, coloque el interruptor en la switch in the "RINSE" position and activating DISPENSE posicón ENJUAGUE/MARCHA (”RINSE/RUN”) y pulse el boton switches. para espumar y distribuir la bebida (”DI
Resumen del contenido incluido en la página 8
GLOSSARY Adjust tank temperature Allows password to be set to pre- TANK TEMP XXX° SET PASSWORD ? (-) EXIT (+) (190° F maximum) (-) XXXX (+) vent altering setup functions Enables “ADS” to be displayed Adjust minimum tank ready temper- ENABLE ADS ? READY TEMP XXX° NO EXIT YES on LCD door display (-) EXIT (+) ature for lockout (185° maximum) Select Portion Control Enter asset number of machine PORTION CONTROL ? ENTER ASSET # ? NO EXIT YES Dispensing EXIT YES Enables service
Resumen del contenido incluido en la página 9
PROGRAMMING THE DISPENSER The following function screens are in order of appearance. Each screen will have instructions on how to access, and the procedures to program the various functions of the dispenser. To enable programming, place the “NORMAL/PROGRAM/RINSE” switch in the “PROGRAM” position. IMPORTANT PROGRAMMING NOTES - READ CAREFULLY To exit the programming mode at any time, press and release the exit (center) pad located on the front switch panel. The display will return to the
Resumen del contenido incluido en la página 10
PROGRAMMING THE DISPENSER (cont.) NORMAL/PROGRAM/RINSE switch: NORMAL: Allows all dispenser functions. Must be in this position for dis- pensing. PROGRAM: Allows access to program menus using touch pad and LCD screen. RINSE: Disables hopper motors. Pressing dispense button on front door will dispense dilution water and power whipper motor for ten seconds. P3060 PROGRAMMING LOCKOUT SWITCH This switch can be set to prevent access to the programming mode of the dispenser. Once all the correct
Resumen del contenido incluido en la página 11
PROGRAMMING THE DISPENSER (cont.) Press and release right switch (advance to next menu), “TANK TEMP XXX°” appears on screen. TANK TEMP XXX° Adjust tank (-) EXIT (+) temperature READY TEMP XXX° ENTER ASSET # ? Adjust minimum tank (-) EXIT (+) EXIT YES ready temperature for lockout PORTION CONTROL ? ENABLE SERVICE ? NO EXIT YES NO EXIT YES continue to J (K) (page 13) DIAGNOSTICS ? STRENGTH ADJ. ? EXIT YES EXIT YES continue to B continue to H (I) (A) (page 12) (page 1
Resumen del contenido incluido en la página 12
PROGRAMMING THE DISPENSER (cont.) (D) Adjust hopper motor speed for SELECT UNITS (B) station selected ENG EXIT METRIC DRINK STRENGTH 1 (-) XX (+) XX° CAL XX° (-) Tank Temp (+) PRESS DISPENSE TO CHECK TASTE TASTE 1 OK ? NO YES 235 REFILL 155 (-) EXIT (+) Goes to next station. Returns to (A) (page Auger Delay 11) after last station. (-) .XX sec (+) Returns to (E) (page 11) 38987 032306 12
Resumen del contenido incluido en la página 13
PROGRAMMING THE DISPENSER (cont.) (F) (H) (J) RINSE ALARM ? TEST SWITCHES ? SET CUP SIZES BY NO EXIT YES Use Switch To Test EXAMPLE TIME DISPENSE UNTIL HEAD 1 SM TIME HEAD 1 DISABLE ? RINSE ALARM TIME TEST HEATER ? CUP IS 3/4 FULL (-) 6.40 SEC (+) (-) XX hours (+) NO EXIT YES EXIT YES Goes to next station. Goes to next station. Press and release RINSE LOCKOUT ? TEST REFILL ? Continues after last Returns to (K) (page any dispense button NO EXIT YES