Resumen del contenido incluido en la página 1
R
INSTALLATION
AND
OPERATING
INSTRUCTIONS
Gas Griddles
MODELS: GGT-18H, -24H, -36H, -48H
&
MODELS: GGM-18H, -24H, -36H, 48H
(US & Canadian units are convertible and are assembled for Natural Gas)
(European units are not convertible and assembled for the appropriate gas)
IMPORTANT FOR FUTURE REFERENCE
Please complete this information and retain this manual for the life of the equipment. For
Warranty Service and/or Parts, this information is required.
Model Number
Resumen del contenido incluido en la página 2
CAUTION: These models are designed, built, and sold for commercial use. If these models are positioned so the general public can use the equipment, make sure that cautions, warnings, and operating instructions are clearly posted near each unit so that ! ! anyone using the equipment will use it correctly and not injure themselves or harm the equipment. WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Rea
Resumen del contenido incluido en la página 3
IMMEDIATELY INSPECT FOR SHIPPING DAMAGE All containers should be examined for damage before and during unloading. The freight carrier has assumed responsibility for its safe transit and delivery. If equipment is received damaged, either apparent or concealed, a claim must be made with the delivering carrier. A) Apparent damage or loss must be noted on the freight bill at the time of delivery. It must then be signed by the carrier representative (Driver). If this is not done, the carrier may
Resumen del contenido incluido en la página 4
WARNING: Keep the appliance free & clear of all combustible substances. If gas odor is detected at any time, immediately shut unit down at the main shutoff valve. Do not permit ! ! any open flames in the area of the appliance. Immediately contact an authorized Service Agency or your local Gas Supplier for service. WARNING: Do not obstruct either the air inlet (underneath unit) or the ventilation air (back ! ! of unit). Provisions must be provided to provide an adequate air sup
Resumen del contenido incluido en la página 5
Caution: DO NOT use an open flame to check for leaks. Check all gas piping for leaks with a soap and water solution before operating unit. THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE SURFACES ONLY. Noncombustible clearances: 0" sides (0 mm) 0" rear (0 mm) 4” floor (102mm) Do not obstruct the flow of combustion and ventilation air, under the unit by the legs or behind the unit by the flue. Adequate clearance for air openings into the combustion chamber is required. Do not plac
Resumen del contenido incluido en la página 6
5. Turn the burner knobs to "HI". If the burner does not ignite, promptly open the pilot valve more. If the pilot flame appears larger than necessary, turn it down and reset burner ignition. The pilot flame should be as small as possible but large enough to guarantee reliable ignition of the burners when the knobs are turned to "HI". Lighting main burner To light burner, turn knob to “max.” Then back off to the desired flame level. The range of adjustment is virtually infinite between high a
Resumen del contenido incluido en la página 7
CLEANING / MAINTENANCE CAUTION: Use only non-abrasive cleaners. Abrasive cleaners could scratch the finish of your unit, marring it’s appearance and making it susceptible to dirt accumulation. Do Not use steel wool, other abrasive cleaners or cleaners/sanitizers containing chlorine, iodine, ammonia or bromine ! ! chemicals as these will deteriorate the stainless steel and glass material and shorten the life of the unit. Initial Cleaning: Prior to operating your new griddle, thoroughl
Resumen del contenido incluido en la página 8
CONVERSION GGT Instructions are for conversion from Natural Gas to Propane (L.P.) on all GGT models . The conversion should be done before connecting the unit to the gas supply. 1. Remove the knobs and front panel. 2. Remove the supply tubes that go between the thermostats and the orifice bracket. 3. Change the orifices to the size recommended for propane (L.P.). For units with a pilot safety valve you must also change the pilot orifice to the other pilot orifice supplied. 4. Replace the suppl
Resumen del contenido incluido en la página 9
CALIBRATION PROCEDURE FOR GGT GRIDDLES Locate the reading positions Make sure the griddle surface is clean. Grease or food particles on the griddle will result in inaccurate thermostat calibration. Mark the locations where the temperature probe will be placed for testing. See the sketch provided. Starting from the left side of the griddle measure 8” to the right and 10-5/8” from the rear splash guard. With a felt tip pen mark this location. This is the location directly over the center of t
Resumen del contenido incluido en la página 10
TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE Heat does not come on Thermostat is bad. when thermostat is turned on. Pilot burner not lit. Gas valve is bad. Pilot burner will not light. Obstructed pilot orifice. Pilot gas turned off at automatic pilot. Automatic pilot valve is bad. Pilot burner will not stay lit. Thermocouple is bad. Thermocouple is not hot enough. Obstructed or wrong size pilot orifice. Gas supply is not purged of air.
Resumen del contenido incluido en la página 11
NOTES 11
Resumen del contenido incluido en la página 12
PARTS LISTS & EXPLODED VIEWS GGM GRIDDLES (EXPLODED VIEW) 1 14 9 56 2 46 47 12 22 6 23 10 18 24 4 45 21 48 50 42 11 29 3 15 39 49 7 44 43 41 17 40 20 19 13 16 25 31 35 5 26 38 28 32 37 33 27 30 34 8 36 12
Resumen del contenido incluido en la página 13
GGM - PARTS LIST ITEM P/N DESCRIPTION QTY. ITEM P/N DESCRIPTION QTY. 1 218215-20 Weldment, Griddle GGM-18 1 24 24251-00 Pan, Grease 18" Varies 218216-20 Weldment, Griddle GGM-24 1 24250-00 Pan, Grease 24" Varies 218217-20 Weldment, Griddle GGM-36 1 25 8861000 Label, Spec 1 218218-20 Weldment, Griddle GGM-48 1 26 218215-12 Panel, Back GGM-18 1 2 218215-11 Body, 18" Firebox GGM 1 218216-12 Panel, Back GGM-24 1 218216-11 Body, 24" Firebox GGM 1 218217-12 Panel, Back GGM-36 1 218217-11 Body,
Resumen del contenido incluido en la página 14
GGT GRIDDLES (EXPLODED VIEW) 44 1 56 28 32 53 33 35 34 16 19 23 8 49 21 64 51 54 66 57 41 65 12 62 60 40 55 63 52 69 2 29 58 59 26 14 39 5 68 24 9 61 50 20 22 25 10 6 18 27 3 13 11 4 37 7 15 38 67 17 48 42 14
Resumen del contenido incluido en la página 15
GGT (PARTS LIST) Item P/N Description Quan Item P/N Description Quan 1 218219-60 Weldment, Griddle, GGT -18 1 30* 2300100 Bags, Poly 36x27x44 1 2 218220-60 Weldment, Griddle, GGT -24 1 32 1018064 Insulation, Thermostat Bulb 218221-60 Weldment, Griddle, GGT -36 1 33 8509300 Washer, Flat, SAE, 5/16 4 218222-60 Weldment, Griddle, GGT -48 1 34 8436200 8 Nut, Hex 5/16-18 S/S 2 2092614 Elbow, 3/8CC X 3/8NPT, No Hood V
Resumen del contenido incluido en la página 16
APW WYOTT EQUIPMENT LIMITED WARRANTY APW Wyott Foodservice Equipment Company warrants it's equipment against defects in materials and workmanship, subject to the following conditions: This warranty applies to the original owner only and is not assignable. Should any product fail to function in its intended manner under normal use within the limits defined in this warranty, at the option of APW Wyott such product will be repaired or replaced by APW Wyott or its Authorized Service Agency. APW W